330 related articles for article (PubMed ID: 16644995)
1. Evaluation of a new self-developing instant film for imaging and dosimetry.
Watanabe Y; Patel GN; Patel P
Radiat Prot Dosimetry; 2006; 120(1-4):121-4. PubMed ID: 16644995
[TBL] [Abstract][Full Text] [Related]
2. The value of EDR2 film dosimetry in compensator-based intensity modulated radiation therapy.
Srivastava RP; De Wagter C
Phys Med Biol; 2007 Oct; 52(19):N449-57. PubMed ID: 17881795
[TBL] [Abstract][Full Text] [Related]
3. Post-irradiation colouration of Gafchromic EBT radiochromic film.
Cheung T; Butson MJ; Yu PK
Phys Med Biol; 2005 Oct; 50(20):N281-5. PubMed ID: 16204869
[TBL] [Abstract][Full Text] [Related]
4. Absorption spectra of irradiated XRCT radiochromic film.
Butson MJ; Cheung T; Yu PK
Phys Med Biol; 2006 Jun; 51(12):3099-103. PubMed ID: 16757865
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
Ferreira BC; Lopes MC; Capela M
Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
[TBL] [Abstract][Full Text] [Related]
6. Application of high-resolution radiochromic film dosimetry in verifying a small-field stereotactic radiosurgery plan.
Lee KY; Fung KK; Kwok CS
Appl Radiat Isot; 2006 Aug; 64(8):934-9. PubMed ID: 16697649
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of the EDR-2 film for relative dosimetry of high-energy photon and electron beams.
Ahmad M; Chen Z; Song H; Deng J; Nath R
Radiat Prot Dosimetry; 2006; 120(1-4):159-62. PubMed ID: 16644932
[TBL] [Abstract][Full Text] [Related]
8. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.
Fuss M; Sturtewagen E; De Wagter C; Georg D
Phys Med Biol; 2007 Jul; 52(14):4211-25. PubMed ID: 17664604
[TBL] [Abstract][Full Text] [Related]
9. EDR2 film dosimetry for IMRT verification using low-energy photon filters.
Yeo IJ; Beiki-Ardakani A; Cho YB; Heydarian M; Zhang T; Islam M
Med Phys; 2004 Jul; 31(7):1960-3. PubMed ID: 15305446
[TBL] [Abstract][Full Text] [Related]
10. Dose and energy dependence of response of Gafchromic XR-QA film for kilovoltage x-ray beams.
Rampado O; Garelli E; Deagostini S; Ropolo R
Phys Med Biol; 2006 Jun; 51(11):2871-81. PubMed ID: 16723772
[TBL] [Abstract][Full Text] [Related]
11. Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance.
Olch AJ
Med Phys; 2002 Sep; 29(9):2159-68. PubMed ID: 12349938
[TBL] [Abstract][Full Text] [Related]
12. New developments in radiochromic film dosimetry.
Soares CG
Radiat Prot Dosimetry; 2006; 120(1-4):100-6. PubMed ID: 16987914
[TBL] [Abstract][Full Text] [Related]
13. EBT GAFCHROMIC(TM) film dosimetry in compensator-based intensity modulated radiation therapy.
Vaezzadeh S; Allahverdi M; Nedaie HA; Ay M; Shirazi A; Yarahmadi M
Med Dosim; 2013; 38(2):176-83. PubMed ID: 23290715
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of a 2D diode array for IMRT quality assurance.
Létourneau D; Gulam M; Yan D; Oldham M; Wong JW
Radiother Oncol; 2004 Feb; 70(2):199-206. PubMed ID: 15028408
[TBL] [Abstract][Full Text] [Related]
15. Absorption spectra variations of EBT radiochromic film from radiation exposure.
Butson MJ; Cheung T; Yu PK
Phys Med Biol; 2005 Jul; 50(13):N135-40. PubMed ID: 15972974
[TBL] [Abstract][Full Text] [Related]
16. Dosimetric quality assurance for intensity-modulated radiotherapy feasibility study for a filmless approach.
Wiezorek T; Banz N; Schwedas M; Scheithauer M; Salz H; Georg D; Wendt TG
Strahlenther Onkol; 2005 Jul; 181(7):468-74. PubMed ID: 15995841
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of GAFCHROMIC EBT film for Cyberknife dosimetry.
Wilcox EE; Daskalov GM
Med Phys; 2007 Jun; 34(6):1967-74. PubMed ID: 17654899
[TBL] [Abstract][Full Text] [Related]
18. GafChromic RTQA film for routine quality assurance of high-energy photon beams.
Thomas MD; Warrington AP
Phys Med Biol; 2006 Mar; 51(6):1439-47. PubMed ID: 16510954
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric evaluation of GAFCHROMIC XR type T and XR type R films.
Dini SA; Koona RA; Ashburn JR; Meigoonia AS
J Appl Clin Med Phys; 2005; 6(1):114-34. PubMed ID: 15770202
[TBL] [Abstract][Full Text] [Related]
20. Quality assurance of brachytherapy afterloaders using a multi-slit phantom.
Kohr P; Siebert FA
Phys Med Biol; 2007 Sep; 52(17):N387-91. PubMed ID: 17762074
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]