292 related articles for article (PubMed ID: 16644999)
1. Deep-trap competition model for TL in alpha-Al2O3:C heating stage.
Kortov VS; Milman II; Moiseykin EV; Nikiforov SV; Ovchinnikov MM
Radiat Prot Dosimetry; 2006; 119(1-4):41-4. PubMed ID: 16644999
[TBL] [Abstract][Full Text] [Related]
2. Influence of absorbed dose and deep traps on thermoluminescence response: a numerical simulation.
Mady F; Bindi R; Iacconi P; Wrobel F
Radiat Prot Dosimetry; 2006; 119(1-4):37-40. PubMed ID: 16644969
[TBL] [Abstract][Full Text] [Related]
3. Ionisation density dependence of the optically and thermally stimulated luminescence from Al2O3:C.
Yukihara EG; McKeever SW
Radiat Prot Dosimetry; 2006; 119(1-4):206-17. PubMed ID: 16585262
[TBL] [Abstract][Full Text] [Related]
4. Thermoluminescence glow curves and optical stimulated luminescence of undoped alpha-Al2O3 crystals.
Zhang CX; Tang Q; Lin LB; Luo DL
Radiat Prot Dosimetry; 2006; 119(1-4):402-7. PubMed ID: 16644982
[TBL] [Abstract][Full Text] [Related]
5. Superlinear dose dependence of high temperature thermoluminescence peaks in Al2O3:C.
Lo D; Lawless JL; Chen R
Radiat Prot Dosimetry; 2006; 119(1-4):71-4. PubMed ID: 16644951
[TBL] [Abstract][Full Text] [Related]
6. Non-monotonic dose dependence of thermoluminescence.
Chen R; Lo D; Lawless JL
Radiat Prot Dosimetry; 2006; 119(1-4):33-6. PubMed ID: 16644974
[TBL] [Abstract][Full Text] [Related]
7. Calculation and properties of trap structural functions for various spatially correlated systems.
Mandowski A
Radiat Prot Dosimetry; 2006; 119(1-4):85-8. PubMed ID: 16702242
[TBL] [Abstract][Full Text] [Related]
8. On the relationship between dose-, energy- and LET-response of thermoluminescent detectors.
Olko P; Bilski P; El-Faramawy NA; Göksu HY; Kim JL; Kopec R; Waligórski MP
Radiat Prot Dosimetry; 2006; 119(1-4):15-22. PubMed ID: 16644968
[TBL] [Abstract][Full Text] [Related]
9. Analysis of the main dosimetric peak of Al2O3:C compounds with a model of interacting traps.
Ortega F; Marcazzó J; Molina P; Santiago M; Lester M; Henniger J; Caselli E
Appl Radiat Isot; 2013 Aug; 78():33-7. PubMed ID: 23665765
[TBL] [Abstract][Full Text] [Related]
10. Optically and thermally stimulated luminescence characteristics of MgO:Tb3+.
Bos AJ; Prokić M; Brouwer JC
Radiat Prot Dosimetry; 2006; 119(1-4):130-3. PubMed ID: 16644952
[TBL] [Abstract][Full Text] [Related]
11. The electron energy dependence of the TL response for CVD diamonds.
Wrobel F; Serrano B; Benabdesselam M; Iacconi P; Costa A
Radiat Prot Dosimetry; 2006; 119(1-4):49-52. PubMed ID: 16735567
[TBL] [Abstract][Full Text] [Related]
12. Influence of the stem effect on radioluminescence signals from optical fibre Al2O3:C dosemeters.
Marckmann CJ; Aznar MC; Andersen CE; Bøtter-Jensen L
Radiat Prot Dosimetry; 2006; 119(1-4):363-7. PubMed ID: 16762967
[TBL] [Abstract][Full Text] [Related]
13. Defect complexes in Re3+-doped magnesium sulphate phosphors.
Luo DL; Tang Q; Zhang CX
Radiat Prot Dosimetry; 2006; 119(1-4):57-61. PubMed ID: 16644940
[TBL] [Abstract][Full Text] [Related]
14. CW-OSL measurement protocols using optical fibre Al2O3:C dosemeters.
Edmund JM; Andersen CE; Marckmann CJ; Aznar MC; Akselrod MS; Bøtter-Jensen L
Radiat Prot Dosimetry; 2006; 119(1-4):368-74. PubMed ID: 16990348
[TBL] [Abstract][Full Text] [Related]
15. The use of optically stimulated luminescence from AL2O3:C in the dosimetry of high-energy heavy charged particle fields.
Gaza R; Yukihara EG; McKeever SW
Radiat Prot Dosimetry; 2006; 120(1-4):354-7. PubMed ID: 16644985
[TBL] [Abstract][Full Text] [Related]
16. Kerma rate effects on thermoluminescent response of CVD diamond.
Wrobel F; Benabdesselam M; Iacconi P; Mady F
Radiat Prot Dosimetry; 2006; 119(1-4):115-8. PubMed ID: 16581925
[TBL] [Abstract][Full Text] [Related]
17. New Al2O3:C,Mg crystals for radiophotoluminescent dosimetry and optical imaging.
Akselrod MS; Akselrod AE
Radiat Prot Dosimetry; 2006; 119(1-4):218-21. PubMed ID: 16606658
[TBL] [Abstract][Full Text] [Related]
18. TL and OSL of SrSO4 phosphors doped with Eu.
Tang Q; Zhang CX; Luo DL; Leung PL; Xiong ZY
Radiat Prot Dosimetry; 2006; 119(1-4):238-43. PubMed ID: 16644983
[TBL] [Abstract][Full Text] [Related]
19. Ionisation density dependence of the optically stimulated luminescence dose-response of AL2O3:C to low-energy charged particles.
Gaza R; Yukihara EG; McKeever SW; Avila O; Buenfil AE; Gamboa-deBuen I; Rodríguez-Villafuerte M; Ruiz-Trejo C; Brandan ME
Radiat Prot Dosimetry; 2006; 119(1-4):375-9. PubMed ID: 16644998
[TBL] [Abstract][Full Text] [Related]
20. The sunlight OSL response of a commercially available alpha-Al2O3:C personnel dosimetry material.
West WG; Kearfott KJ; Bernal SM
Radiat Prot Dosimetry; 2006; 119(1-4):344-9. PubMed ID: 16644934
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]