These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 16646415)

  • 1. [Study on surface modification and biocompatibility of NiTi alloy intravascular stents].
    Shen Y; Wang GX; Quan XJ; Yu QS
    Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Jan; 30(1):3-6, 38. PubMed ID: 16646415
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of surface microroughness by plasma deposition and chemical erosion followed by TiO2 coating upon anticoagulation, hydrophilicity, and corrosion resistance of NiTi alloy stent.
    Wang GX; Shen Y; Zhang H; Quan XJ; Yu QS
    J Biomed Mater Res A; 2008 Jun; 85(4):1096-102. PubMed ID: 17941010
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Polymeric coating of surface modified nitinol stent with POSS-nanocomposite polymer.
    Bakhshi R; Darbyshire A; Evans JE; You Z; Lu J; Seifalian AM
    Colloids Surf B Biointerfaces; 2011 Aug; 86(1):93-105. PubMed ID: 21515031
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biocompatibility study of plasma-coated nitinol (NiTi alloy) stents.
    Wang G; Shen Y; Cao Y; Yu Q; Guidoin R
    IET Nanobiotechnol; 2007 Dec; 1(6):102-6. PubMed ID: 18035911
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy.
    Chu CL; Guo C; Sheng XB; Dong YS; Lin PH; Yeung KW; Chu PK
    Acta Biomater; 2009 Jul; 5(6):2238-45. PubMed ID: 19251496
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Behaviour of human endothelial cells on surface modified NiTi alloy.
    Plant SD; Grant DM; Leach L
    Biomaterials; 2005 Sep; 26(26):5359-67. PubMed ID: 15814134
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 8. NiTi shape memory alloys treated by plasma-polymerized tetrafluoroethylene. A physicochemical and electrochemical characterization.
    Yahia LH; Lombardi S; Piron D; Klemberg-Sapieha JE; Wertheimer MR
    Med Prog Technol; 1996-1997; 21(4):187-93. PubMed ID: 9110276
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Surface characteristics, mechanical properties, and cytocompatibility of oxygen plasma-implanted porous nickel titanium shape memory alloy.
    Wu SL; Chu PK; Liu XM; Chung CY; Ho JP; Chu CL; Tjong SC; Yeung KW; Lu WW; Cheung KM; Luk KD
    J Biomed Mater Res A; 2006 Oct; 79(1):139-46. PubMed ID: 16779766
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Initial exploration of Ti-Ta, Ti-Ta-Ir and Ti-Ir alloys: Candidate materials for coronary stents.
    O'Brien B; Stinson J; Carroll W
    Acta Biomater; 2008 Sep; 4(5):1553-9. PubMed ID: 18396116
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation.
    Chu CL; Hu T; Wu SL; Dong YS; Yin LH; Pu YP; Lin PH; Chung CY; Yeung KW; Chu PK
    Acta Biomater; 2007 Sep; 3(5):795-806. PubMed ID: 17466609
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Auricle reconstruction with a nickel-titanium shape memory alloy as the framework.
    Chi FL; Wang SJ; Liu HJ
    Laryngoscope; 2007 Feb; 117(2):248-52. PubMed ID: 17202909
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biocompatibility and hemocompatibility of surface-modified NiTi alloys.
    Armitage DA; Parker TL; Grant DM
    J Biomed Mater Res A; 2003 Jul; 66(1):129-37. PubMed ID: 12833439
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Surface characteristics, biocompatibility, and mechanical properties of nickel-titanium plasma-implanted with nitrogen at different implantation voltages.
    Liu XM; Wu SL; Chan YL; Chu PK; Chung CY; Chu CL; Yeung KW; Lu WW; Cheung KM; Luk KD
    J Biomed Mater Res A; 2007 Aug; 82(2):469-78. PubMed ID: 17295249
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Corrosion resistance improvement of NiTi osteosynthesis staples by plasma polymerized tetrafluoroethylene coating.
    Villermaux F; Tabrizian M; Yahia L; Czeremuszkin G; Piron DL
    Biomed Mater Eng; 1996; 6(4):241-54. PubMed ID: 8980833
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The relationship of metal intravascular stand's surface composition and design to haemocompatibility].
    Xiao M; Ling Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Feb; 22(1):217-20. PubMed ID: 15762154
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Enhanced surface hardness by boron implantation in Nitinol alloy.
    Lee DH; Park B; Saxena A; Serene TP
    J Endod; 1996 Oct; 22(10):543-6. PubMed ID: 9198443
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ti-TiC-TiC/DLC gradient nano-composite film on a biomedical NiTi alloy.
    Zheng Y; Liu D; Liu X; Li L
    Biomed Mater; 2008 Dec; 3(4):044103. PubMed ID: 19029600
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Density functional theory simulation of titanium migration and reaction with oxygen in the early stages of oxidation of equiatomic NiTi alloy.
    Nolan M; Tofail SA
    Biomaterials; 2010 May; 31(13):3439-48. PubMed ID: 20144474
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Studies and applications of NiTi shape memory alloys in the medical field in China.
    Dai K; Chu Y
    Biomed Mater Eng; 1996; 6(4):233-40. PubMed ID: 8980832
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.