BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 16650273)

  • 1. Early left ventricular lead dislodgement related to hyperpnea respiration.
    Chan JY; Fung JW; Yu CM
    Pacing Clin Electrophysiol; 2006 Apr; 29(4):425-6. PubMed ID: 16650273
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [An old ventricular lead migration and subsequent dislodgement to the pleural cavity - an unusual complication of permanent cardiac pacing].
    Adamowicz-Czoch E; Głowacki J; Hawranek M; Dziubek B; Gierlotka M; Zembala M
    Kardiol Pol; 2008 Aug; 66(8):869-72. PubMed ID: 18803139
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impacted left ventricular lead technique in cardiac resynchronization therapy.
    Chan NY; Lo YK
    Europace; 2007 Jul; 9(7):531-2. PubMed ID: 17522082
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Left ventricular lead stabilization utilizing a coronary stent.
    Cesario DA; Shenoda M; Brar R; Shivkumar K
    Pacing Clin Electrophysiol; 2006 Apr; 29(4):427-8. PubMed ID: 16650274
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Left ventricular pacemaker-lead implantation through left thoracotomy for cardiac resynchronization therapy].
    Tokui T; Kishi N; Yada M; Maze Y; Shomura S
    Kyobu Geka; 2008 May; 61(5):367-70. PubMed ID: 18464480
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simulation of LV pacemaker lead in marginal vein: potential risk factors for acute dislodgement.
    Zhao X; Burger M; Liu Y; Das MK; Combs W; Wenk JF; Guccione JM; Kassab GS
    J Biomech Eng; 2011 Mar; 133(3):031006. PubMed ID: 21303182
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Late left ventricular lead displacement and treatment with a new endovenous active fixation lead.
    Khadjooi K; Foley PW; Smith RE
    Europace; 2007 Dec; 9(12):1182-3. PubMed ID: 17704096
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stent-stabilization of left ventricular pacing leads for cardiac resynchronization therapy: a promising concept?
    Ermis C; Benditt DG
    J Cardiovasc Electrophysiol; 2007 Mar; 18(3):308-9. PubMed ID: 17284283
    [No Abstract]   [Full Text] [Related]  

  • 9. Resynchronization: what if the left ventricular lead cannot reach the lateral or posterolateral wall?
    D'Ivernois C; Lesage J; Blanc P
    Pacing Clin Electrophysiol; 2008 Aug; 31(8):1041-5. PubMed ID: 18684261
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of right ventricular lead location on response to cardiac resynchronization therapy in patients with end-stage heart failure.
    Haghjoo M; Bonakdar HR; Jorat MV; Fazelifar AF; Alizadeh A; Ojaghi-Haghjghi Z; Esmaielzadeh M; Sadr-Ameli MA
    Europace; 2009 Mar; 11(3):356-63. PubMed ID: 19136489
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Usefulness of a pacing guidewire to facilitate left ventricular lead implantation in cardiac resynchronization therapy.
    de Cock CC; Res JC; Hendriks ML; Allaart CP
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):446-9. PubMed ID: 19335852
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Coronary sinus lead fragmentation 2 years after implantation with a retained guidewire.
    Nägele H; Hashagen S; Ergin M; Azizi M; Behrens S
    Pacing Clin Electrophysiol; 2007 Mar; 30(3):438-9. PubMed ID: 17367367
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Very-late proarrhythmia of a migrant pacemaker lead.
    Stein A; Mazzitelli D; Kolb C
    J Electrocardiol; 2011; 44(2):232-4. PubMed ID: 20888005
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [The significance of electrocardiogram in the estimation of correct lead position in patients with permanent ventricular pacing].
    Zielińska M; Kaczmarek K; Koniarek W; Goch JH
    Wiad Lek; 2006; 59(7-8):580-4. PubMed ID: 17209366
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Left ventricular malposition of pacemaker lead in Chagas' disease.
    Chun JK; Bode F; Wiegand UK
    Pacing Clin Electrophysiol; 2004 Dec; 27(12):1682-5. PubMed ID: 15613133
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of coronary venous angioplasty to facilitate optimal placement of left ventricular lead during CRT.
    Osman F; Kundu S; Tuan J; Pathmanathan RK
    Pacing Clin Electrophysiol; 2009 Feb; 32(2):281-2. PubMed ID: 19170924
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Feasibility, safety, and mid-term efficacy of cardiac resynchronization therapy in patients with severe heart failure and ventricular conduction delay: Chulalongkorn experience.
    Sunsaneewitayakul B; Sitthisook S; Sangwatanaroj S; Prechawat S; Songmuang SB
    J Med Assoc Thai; 2007 Jul; 90(7):1458-66. PubMed ID: 17710992
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Left ventricular lead: unusual implantation failure.
    Granier M; Micheau A; Cung TT; Demaria R; Davy JM
    Europace; 2008 Aug; 10(8):1026-7. PubMed ID: 18586860
    [No Abstract]   [Full Text] [Related]  

  • 19. [An old looped lead removal, complicated by its knotting over the active right ventricular lead - a case report].
    Małecka B; Kutarski A; Pietura R; Zabek A; Bednarek J; Lelakowski J; Szczerbo-Trojanowska M
    Kardiol Pol; 2008 Aug; 66(8):865-8. PubMed ID: 18803138
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Importance of left ventricular lead position in cardiac resynchronization therapy.
    Bleeker GB; Schalij MJ; Bax JJ
    Eur Heart J; 2007 May; 28(10):1182-3. PubMed ID: 17459903
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.