These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

226 related articles for article (PubMed ID: 16674627)

  • 1. The pressure required to force liquid through breathing system filters.
    Cann C; Hampson MA; Wilkes AR; Hall JE
    Anaesthesia; 2006 May; 61(5):492-7. PubMed ID: 16674627
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of flow on the filtration performance of paediatric breathing system filters.
    Wilkes AR; Malan CA; Hall JE
    Anaesthesia; 2008 Jan; 63(1):71-6. PubMed ID: 18086073
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of volatile anaesthetic agents on the filtration performance of paediatric breathing system filters.
    Froom SR; Cann C; Wilkes AR; Gildersleve C; Hall JE
    Anaesthesia; 2008 Jan; 63(1):77-81. PubMed ID: 18086074
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of desflurane on filtration performance of breathing system filters.
    Poonawala Y; Wilkes AR; Cann C; Hall JE
    Anaesthesia; 2010 Aug; 65(8):831-5. PubMed ID: 20590531
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of patient factors on the efficacy of breathing system filters at preventing contamination of breathing systems.
    Dugani S; Kumar A; Wilkes AR
    Anaesthesia; 2010 May; 65(5):468-72. PubMed ID: 20345423
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The use of filters with small infants.
    Whitelock DE; de Beer DA
    Respir Care Clin N Am; 2006 Jun; 12(2):307-20. PubMed ID: 16828697
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The ability of breathing system filters to prevent liquid contamination of breathing systems: a laboratory study.
    Wilkes AR
    Anaesthesia; 2002 Jan; 57(1):33-9. PubMed ID: 11843739
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An evaluation of the filtration performance of paediatric breathing system filters at low flows.
    Malan CA; Wilkes AR; Hall JE; Gildersleve C
    Anaesthesia; 2007 May; 62(5):504-8. PubMed ID: 17448064
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of loading on the filtration performance of breathing system filters.
    Wilkes AR
    Anaesthesia; 2003 Jun; 58(6):562-7. PubMed ID: 12846622
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measuring the filtration performance of breathing system filters using sodium chloride particles.
    Wilkes AR
    Anaesthesia; 2002 Feb; 57(2):162-8. PubMed ID: 11871953
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Breathing system filters for paediatric practice.
    Bennett NR; Bingham R
    Anaesthesia; 2007 Feb; 62(2):192-3; author reply 193. PubMed ID: 17223817
    [No Abstract]   [Full Text] [Related]  

  • 12. Passage of pathogenic microorganisms through breathing system filters used in anaesthesia and intensive care.
    Scott DH; Fraser S; Willson P; Drummond GB; Baillie JK
    Anaesthesia; 2010 Jul; 65(7):670-3. PubMed ID: 20374232
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessing the efficacy of HME filters at preventing contamination of breathing systems.
    Rees LM; Sheraton TE; Modestini C; Wilkes AR; Hall JE
    Anaesthesia; 2007 Jan; 62(1):67-71. PubMed ID: 17156229
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of gas flow on the filtration performance of breathing system filters.
    Wilkes AR
    Anaesthesia; 2004 Mar; 59(3):278-82. PubMed ID: 14984527
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of manufacturers' specifications for 44 types of heat and moisture exchanging filters.
    Dellamonica J; Boisseau N; Goubaux B; Raucoules-Aimé M
    Br J Anaesth; 2004 Oct; 93(4):532-9. PubMed ID: 15298877
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The bacterial and viral filtration performance of breathing system filters.
    Wilkes AR; Benbough JE; Speight SE; Harmer M
    Anaesthesia; 2000 May; 55(5):458-65. PubMed ID: 10792138
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The influence of breathing system filters on paediatric capnography.
    Hardman JG; Mahajan RP; Curran J
    Paediatr Anaesth; 1999; 9(1):35-8. PubMed ID: 10712713
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Prevention of cross contamination, patient to anesthesia apparatus to patient, using filters].
    Cochs J; Casals P; Villalonga R; Vences A; Irujo J; Suárez M
    Rev Esp Anestesiol Reanim; 1994; 41(6):322-7. PubMed ID: 7838999
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The reuse of breathing systems in anesthesia.
    Carter JA
    Respir Care Clin N Am; 2006 Jun; 12(2):275-86. PubMed ID: 16828695
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An audit into the efficacy of single use bacterial/viral filters for the prevention of equipment contamination during lung function assessment.
    Unstead M; Stearn MD; Cramer D; Chadwick MV; Wilson R
    Respir Med; 2006 May; 100(5):946-50. PubMed ID: 16242312
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.