4219 related articles for article (PubMed ID: 16675869)
1. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
Ding GX; Duggan DM; Coffey CW
Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
[TBL] [Abstract][Full Text] [Related]
2. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
Sikora M; Dohm O; Alber M
Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
[TBL] [Abstract][Full Text] [Related]
3. A theoretical approach for non-equilibrium radiation dosimetry.
Ding GX; Duggan DM; Coffey CW
Phys Med Biol; 2008 Jul; 53(13):3493-9. PubMed ID: 18552420
[TBL] [Abstract][Full Text] [Related]
4. Development of a Monte Carlo model for the Brainlab microMLC.
Belec J; Patrocinio H; Verhaegen F
Phys Med Biol; 2005 Mar; 50(5):787-99. PubMed ID: 15798255
[TBL] [Abstract][Full Text] [Related]
5. Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy.
Ding GX; Duggan DM; Coffey CW
Phys Med Biol; 2007 Mar; 52(6):1595-615. PubMed ID: 17327651
[TBL] [Abstract][Full Text] [Related]
6. A practical Monte Carlo MU verification tool for IMRT quality assurance.
Fan J; Li J; Chen L; Stathakis S; Luo W; Du Plessis F; Xiong W; Yang J; Ma CM
Phys Med Biol; 2006 May; 51(10):2503-15. PubMed ID: 16675866
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of a commercial VMC++ Monte Carlo based treatment planning system for electron beams using EGSnrc/BEAMnrc simulations and measurements.
Edimo P; Clermont C; Kwato MG; Vynckier S
Phys Med; 2009 Sep; 25(3):111-21. PubMed ID: 18722148
[TBL] [Abstract][Full Text] [Related]
8. Comparison of PENELOPE Monte Carlo dose calculations with Fricke dosimeter and ionization chamber measurements in heterogeneous phantoms (18 MeV electron and 12 MV photon beams).
Blazy L; Baltes D; Bordy JM; Cutarella D; Delaunay F; Gouriou J; Leroy E; Ostrowsky A; Beaumont S
Phys Med Biol; 2006 Nov; 51(22):5951-65. PubMed ID: 17068376
[TBL] [Abstract][Full Text] [Related]
9. On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations.
Fogliata A; Vanetti E; Albers D; Brink C; Clivio A; Knöös T; Nicolini G; Cozzi L
Phys Med Biol; 2007 Mar; 52(5):1363-85. PubMed ID: 17301460
[TBL] [Abstract][Full Text] [Related]
10. Improvement of radiological penumbra using intermediate energy photons (IEP) for stereotactic radiosurgery.
O'Malley L; Pignol JP; Beachey DJ; Keller BM; Presutti J; Sharpe M
Phys Med Biol; 2006 May; 51(10):2537-48. PubMed ID: 16675868
[TBL] [Abstract][Full Text] [Related]
11. Monte Carlo modeling of the ModuLeaf miniature MLC for small field dosimetry and quality assurance of the clinical treatment planning system.
Crop F; Reynaert N; Pittomvils G; Paelinck L; De Gersem W; De Wagter C; Vakaet L; De Neve W; Thierens H
Phys Med Biol; 2007 Jun; 52(11):3275-90. PubMed ID: 17505102
[TBL] [Abstract][Full Text] [Related]
12. Monte Carlo simulation of the photon beam characteristics from medical linear accelerators.
Kim HK; Han SJ; Kim JL; Kim BH; Chang SY; Lee JK
Radiat Prot Dosimetry; 2006; 119(1-4):510-3. PubMed ID: 16644954
[TBL] [Abstract][Full Text] [Related]
13. Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams.
Künzler T; Fotina I; Stock M; Georg D
Phys Med Biol; 2009 Dec; 54(24):7363-77. PubMed ID: 19934489
[TBL] [Abstract][Full Text] [Related]
14. Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems.
Paelinck L; Reynaert N; Thierens H; De Neve W; De Wagter C
Phys Med Biol; 2005 May; 50(9):2055-69. PubMed ID: 15843736
[TBL] [Abstract][Full Text] [Related]
15. Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code.
Panettieri V; Duch MA; Jornet N; Ginjaume M; Carrasco P; Badal A; Ortega X; Ribas M
Phys Med Biol; 2007 Jan; 52(1):303-16. PubMed ID: 17183143
[TBL] [Abstract][Full Text] [Related]
16. Monte Carlo study of a Cyberknife stereotactic radiosurgery system.
Araki F
Med Phys; 2006 Aug; 33(8):2955-63. PubMed ID: 16964874
[TBL] [Abstract][Full Text] [Related]
17. Beam characteristics and stopping-power ratios of small radiosurgery photon beams.
Ding GX; Ding F
Phys Med Biol; 2012 Sep; 57(17):5509-21. PubMed ID: 22872136
[TBL] [Abstract][Full Text] [Related]
18. Effect of transverse magnetic fields on dose distribution and RBE of photon beams: comparing PENELOPE and EGS4 Monte Carlo codes.
Nettelbeck H; Takacs GJ; Rosenfeld AB
Phys Med Biol; 2008 Sep; 53(18):5123-37. PubMed ID: 18723929
[TBL] [Abstract][Full Text] [Related]
19. Monte Carlo simulation of a medical linear accelerator for radiotherapy use.
Serrano B; Hachem A; Franchisseur E; Hérault J; Marcié S; Costa A; Bensadoun RJ; Barthe J; Gérard JP
Radiat Prot Dosimetry; 2006; 119(1-4):506-9. PubMed ID: 16644964
[TBL] [Abstract][Full Text] [Related]
20. AAA and PBC calculation accuracy in the surface build-up region in tangential beam treatments. Phantom and breast case study with the Monte Carlo code PENELOPE.
Panettieri V; Barsoum P; Westermark M; Brualla L; Lax I
Radiother Oncol; 2009 Oct; 93(1):94-101. PubMed ID: 19541380
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]