188 related articles for article (PubMed ID: 16677762)
1. A femtogram resolution mass sensor platform based on SOI electrostatically driven resonant cantilever. Part II: sensor calibration and glycerine evaporation rate measurement.
Teva J; Abadal G; Torres F; Verd J; Pérez-Murano F; Barniol N
Ultramicroscopy; 2006; 106(8-9):808-14. PubMed ID: 16677762
[TBL] [Abstract][Full Text] [Related]
2. A femtogram resolution mass sensor platform, based on SOI electrostatically driven resonant cantilever. Part I: electromechanical model and parameter extraction.
Teva J; Abadal G; Torres F; Verd J; Pérez-Murano F; Barniol N
Ultramicroscopy; 2006; 106(8-9):800-7. PubMed ID: 16675119
[TBL] [Abstract][Full Text] [Related]
3. Atomic force microscope characterization of a resonating nanocantilever.
Abadal G; Davis ZJ; Borrisé X; Hansen O; Boisen A; Barniol N; Pérez-Murano F; Serra F
Ultramicroscopy; 2003; 97(1-4):127-33. PubMed ID: 12801665
[TBL] [Abstract][Full Text] [Related]
4. Magnetically actuated complementary metal oxide semiconductor resonant cantilever gas sensor systems.
Vancura C; Rüegg M; Li Y; Hagleitner C; Hierlemann A
Anal Chem; 2005 May; 77(9):2690-9. PubMed ID: 15859582
[TBL] [Abstract][Full Text] [Related]
5. Microdrops on atomic force microscope cantilevers: evaporation of water and spring constant calibration.
Bonaccurso E; Butt HJ
J Phys Chem B; 2005 Jan; 109(1):253-63. PubMed ID: 16851011
[TBL] [Abstract][Full Text] [Related]
6. Microresonator mass sensors for detection of Bacillus anthracis Sterne spores in air and water.
Davila AP; Jang J; Gupta AK; Walter T; Aronson A; Bashir R
Biosens Bioelectron; 2007 Jun; 22(12):3028-35. PubMed ID: 17317142
[TBL] [Abstract][Full Text] [Related]
7. Liquid-phase chemical and biochemical detection using fully integrated magnetically actuated complementary metal oxide semiconductor resonant cantilever sensor systems.
Vancura C; Li Y; Lichtenberg J; Kirstein KU; Hierlemann A; Josse F
Anal Chem; 2007 Feb; 79(4):1646-54. PubMed ID: 17297968
[TBL] [Abstract][Full Text] [Related]
8. On the electromechanical modelling of a resonating nano-cantilever-based transducer.
Teva J; Abadal G; Davis ZJ; Verd J; Borrisé X; Boisen A; Pérez-Murano F; Barniol N
Ultramicroscopy; 2004 Aug; 100(3-4):225-32. PubMed ID: 15231314
[TBL] [Abstract][Full Text] [Related]
9. Nondestructive and noncontact method for determining the spring constant of rectangular cantilevers.
Golovko DS; Haschke T; Wiechert W; Bonaccurso E
Rev Sci Instrum; 2007 Apr; 78(4):043705. PubMed ID: 17477668
[TBL] [Abstract][Full Text] [Related]
10. Calibration and examination of piezoresistive Wheatstone bridge cantilevers for scanning probe microscopy.
Gotszalk T; Grabiec P; Rangelow IW
Ultramicroscopy; 2003; 97(1-4):385-9. PubMed ID: 12801693
[TBL] [Abstract][Full Text] [Related]
11. Waveguide micro-opto-electro-mechanical resonant chemical sensors.
Pruessner MW; Stievater TH; Ferraro MS; Rabinovich WS; Stepnowski JL; McGill RA
Lab Chip; 2010 Mar; 10(6):762-8. PubMed ID: 20221565
[TBL] [Abstract][Full Text] [Related]
12. Optical calibration for both out-of-plane and in-plane displacement sensitivity of acoustic emission sensors.
Theobald PD
Ultrasonics; 2009 Dec; 49(8):623-7. PubMed ID: 19409592
[TBL] [Abstract][Full Text] [Related]
13. Measuring the cantilever-position-sensitive detector distance and cantilever curvature for cantilever sensor applications.
Xu M; Tian Y; Coates ML; Beaulieu LY
Rev Sci Instrum; 2009 Sep; 80(9):095114. PubMed ID: 19791971
[TBL] [Abstract][Full Text] [Related]
14. Cancellation of environmental effects in resonant mass sensors based on resonance mode and effective mass.
Naeli K; Brand O
Rev Sci Instrum; 2009 Jun; 80(6):063903. PubMed ID: 19566211
[TBL] [Abstract][Full Text] [Related]
15. Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection.
Bertke M; Xu J; Fahrbach M; Setiono A; Wasisto HS; Peiner E
Sensors (Basel); 2019 Feb; 19(4):. PubMed ID: 30795547
[TBL] [Abstract][Full Text] [Related]
16. Thermal imaging with tapping mode using a bimetal oscillator formed at the end of a cantilever.
Kim SJ; Ono T; Esashi M
Rev Sci Instrum; 2009 Mar; 80(3):033703. PubMed ID: 19334923
[TBL] [Abstract][Full Text] [Related]
17. Calibration of AFM cantilever spring constants.
Gibson CT; Weeks BL; Abell C; Rayment T; Myhra S
Ultramicroscopy; 2003; 97(1-4):113-8. PubMed ID: 12801663
[TBL] [Abstract][Full Text] [Related]
18. Resonance-mode effect on microcantilever mass-sensing performance in air.
Xia X; Li X
Rev Sci Instrum; 2008 Jul; 79(7):074301. PubMed ID: 18681721
[TBL] [Abstract][Full Text] [Related]
19. Mass detection using capacitive resonant silicon resonator employing LC resonant circuit technique.
Kim SJ; Ono T; Esashi M
Rev Sci Instrum; 2007 Aug; 78(8):085103. PubMed ID: 17764351
[TBL] [Abstract][Full Text] [Related]
20. Calibration of lateral force measurements in atomic force microscopy with a piezoresistive force sensor.
Xie H; Vitard J; Haliyo S; Régnier S; Boukallel M
Rev Sci Instrum; 2008 Mar; 79(3):033708. PubMed ID: 18377016
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]