BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 16677762)

  • 1. A femtogram resolution mass sensor platform based on SOI electrostatically driven resonant cantilever. Part II: sensor calibration and glycerine evaporation rate measurement.
    Teva J; Abadal G; Torres F; Verd J; Pérez-Murano F; Barniol N
    Ultramicroscopy; 2006; 106(8-9):808-14. PubMed ID: 16677762
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A femtogram resolution mass sensor platform, based on SOI electrostatically driven resonant cantilever. Part I: electromechanical model and parameter extraction.
    Teva J; Abadal G; Torres F; Verd J; Pérez-Murano F; Barniol N
    Ultramicroscopy; 2006; 106(8-9):800-7. PubMed ID: 16675119
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Atomic force microscope characterization of a resonating nanocantilever.
    Abadal G; Davis ZJ; Borrisé X; Hansen O; Boisen A; Barniol N; Pérez-Murano F; Serra F
    Ultramicroscopy; 2003; 97(1-4):127-33. PubMed ID: 12801665
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Magnetically actuated complementary metal oxide semiconductor resonant cantilever gas sensor systems.
    Vancura C; Rüegg M; Li Y; Hagleitner C; Hierlemann A
    Anal Chem; 2005 May; 77(9):2690-9. PubMed ID: 15859582
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microdrops on atomic force microscope cantilevers: evaporation of water and spring constant calibration.
    Bonaccurso E; Butt HJ
    J Phys Chem B; 2005 Jan; 109(1):253-63. PubMed ID: 16851011
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microresonator mass sensors for detection of Bacillus anthracis Sterne spores in air and water.
    Davila AP; Jang J; Gupta AK; Walter T; Aronson A; Bashir R
    Biosens Bioelectron; 2007 Jun; 22(12):3028-35. PubMed ID: 17317142
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Liquid-phase chemical and biochemical detection using fully integrated magnetically actuated complementary metal oxide semiconductor resonant cantilever sensor systems.
    Vancura C; Li Y; Lichtenberg J; Kirstein KU; Hierlemann A; Josse F
    Anal Chem; 2007 Feb; 79(4):1646-54. PubMed ID: 17297968
    [TBL] [Abstract][Full Text] [Related]  

  • 8. On the electromechanical modelling of a resonating nano-cantilever-based transducer.
    Teva J; Abadal G; Davis ZJ; Verd J; Borrisé X; Boisen A; Pérez-Murano F; Barniol N
    Ultramicroscopy; 2004 Aug; 100(3-4):225-32. PubMed ID: 15231314
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nondestructive and noncontact method for determining the spring constant of rectangular cantilevers.
    Golovko DS; Haschke T; Wiechert W; Bonaccurso E
    Rev Sci Instrum; 2007 Apr; 78(4):043705. PubMed ID: 17477668
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calibration and examination of piezoresistive Wheatstone bridge cantilevers for scanning probe microscopy.
    Gotszalk T; Grabiec P; Rangelow IW
    Ultramicroscopy; 2003; 97(1-4):385-9. PubMed ID: 12801693
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Waveguide micro-opto-electro-mechanical resonant chemical sensors.
    Pruessner MW; Stievater TH; Ferraro MS; Rabinovich WS; Stepnowski JL; McGill RA
    Lab Chip; 2010 Mar; 10(6):762-8. PubMed ID: 20221565
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optical calibration for both out-of-plane and in-plane displacement sensitivity of acoustic emission sensors.
    Theobald PD
    Ultrasonics; 2009 Dec; 49(8):623-7. PubMed ID: 19409592
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measuring the cantilever-position-sensitive detector distance and cantilever curvature for cantilever sensor applications.
    Xu M; Tian Y; Coates ML; Beaulieu LY
    Rev Sci Instrum; 2009 Sep; 80(9):095114. PubMed ID: 19791971
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cancellation of environmental effects in resonant mass sensors based on resonance mode and effective mass.
    Naeli K; Brand O
    Rev Sci Instrum; 2009 Jun; 80(6):063903. PubMed ID: 19566211
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection.
    Bertke M; Xu J; Fahrbach M; Setiono A; Wasisto HS; Peiner E
    Sensors (Basel); 2019 Feb; 19(4):. PubMed ID: 30795547
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Thermal imaging with tapping mode using a bimetal oscillator formed at the end of a cantilever.
    Kim SJ; Ono T; Esashi M
    Rev Sci Instrum; 2009 Mar; 80(3):033703. PubMed ID: 19334923
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calibration of AFM cantilever spring constants.
    Gibson CT; Weeks BL; Abell C; Rayment T; Myhra S
    Ultramicroscopy; 2003; 97(1-4):113-8. PubMed ID: 12801663
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Resonance-mode effect on microcantilever mass-sensing performance in air.
    Xia X; Li X
    Rev Sci Instrum; 2008 Jul; 79(7):074301. PubMed ID: 18681721
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mass detection using capacitive resonant silicon resonator employing LC resonant circuit technique.
    Kim SJ; Ono T; Esashi M
    Rev Sci Instrum; 2007 Aug; 78(8):085103. PubMed ID: 17764351
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calibration of lateral force measurements in atomic force microscopy with a piezoresistive force sensor.
    Xie H; Vitard J; Haliyo S; Régnier S; Boukallel M
    Rev Sci Instrum; 2008 Mar; 79(3):033708. PubMed ID: 18377016
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.