These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 16677762)

  • 41. Single-scan measurement of conductance of a quartz crystal microbalance array coupled with resonant markers for biosensing in liquid phase.
    Hsiao HY; Chen RL; Cheng TJ
    Rev Sci Instrum; 2009 Apr; 80(4):044301. PubMed ID: 19405677
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Fiber-optic, cantilever-type acoustic motion velocity hydrophone.
    Cranch GA; Miller GA; Kirkendall CK
    J Acoust Soc Am; 2012 Jul; 132(1):103-14. PubMed ID: 22779459
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Atomic force microscope cantilever spring constant evaluation for higher mode oscillations: a kinetostatic method.
    Tseytlin YM
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):025102. PubMed ID: 18315324
    [TBL] [Abstract][Full Text] [Related]  

  • 44. A resonant sensor composed of quartz double ended tuning fork and silicon substrate for digital acceleration measurement.
    Li C; Zhao Y; Cheng R; Yu Z; Liu Y
    Rev Sci Instrum; 2014 Mar; 85(3):035004. PubMed ID: 24689613
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Calibration of the normal spring constant of microcantilevers in a parallel fluid flow.
    Lubarsky GV; Hähner G
    Rev Sci Instrum; 2007 Sep; 78(9):095102. PubMed ID: 17902969
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Coupled determination of gravimetric and elastic effects on two resonant chemical sensors: love wave and microcantilever platforms.
    Fadel L; Zimmermann C; Dufour I; Déjous C; Rebière D; Pistré J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Feb; 52(2):297-303. PubMed ID: 15801317
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A MEMS Resonant Sensor to Measure Fluid Density and Viscosity under Flexural and Torsional Vibrating Modes.
    Zhao L; Hu Y; Wang T; Ding J; Liu X; Zhao Y; Jiang Z
    Sensors (Basel); 2016 Jun; 16(6):. PubMed ID: 27275823
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Study of the sensitivity of the first four flexural modes of an AFM cantilever with a sidewall probe.
    Chang WJ; Lee HL; Chen TY
    Ultramicroscopy; 2008 Jun; 108(7):619-24. PubMed ID: 18037563
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Mass determination and sensitivity based on resonance frequency changes of the higher flexural modes of cantilever sensors.
    Parkin JD; Hähner G
    Rev Sci Instrum; 2011 Mar; 82(3):035108. PubMed ID: 21456790
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Method for label-free detection of femtogram quantities of biologics in flowing liquid samples.
    Maraldo D; Rijal K; Campbell G; Mutharasan R
    Anal Chem; 2007 Apr; 79(7):2762-70. PubMed ID: 17309231
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Digital control of force microscope cantilevers using a field programmable gate array.
    Jacky JP; Garbini JL; Ettus M; Sidles JA
    Rev Sci Instrum; 2008 Dec; 79(12):123705. PubMed ID: 19123567
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Real time mass flow rate measurement using multiple fan beam optical tomography.
    Abdul Rahim R; Leong LC; Chan KS; Rahiman MH; Pang JF
    ISA Trans; 2008 Jan; 47(1):3-14. PubMed ID: 17709106
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Improved lateral force calibration based on the angle conversion factor in atomic force microscopy.
    Choi D; Hwang W; Yoon E
    J Microsc; 2007 Nov; 228(Pt 2):190-9. PubMed ID: 17970919
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Calibration of higher eigenmodes of cantilevers.
    Labuda A; Kocun M; Lysy M; Walsh T; Meinhold J; Proksch T; Meinhold W; Anderson C; Proksch R
    Rev Sci Instrum; 2016 Jul; 87(7):073705. PubMed ID: 27475563
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Wideband low-noise optical beam deflection sensor with photothermal excitation for liquid-environment atomic force microscopy.
    Fukuma T
    Rev Sci Instrum; 2009 Feb; 80(2):023707. PubMed ID: 19256653
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Generalized model of resonant polymer-coated microcantilevers in viscous liquid media.
    Cox R; Josse F; Wenzel MJ; Heinrich SM; Dufour I
    Anal Chem; 2008 Aug; 80(15):5760-7. PubMed ID: 18590281
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting.
    Nyang'au WO; Setiono A; Schmidt A; Bosse H; Peiner E
    Sensors (Basel); 2020 Apr; 20(9):. PubMed ID: 32354176
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A tip-coupled, two-cantilever, non-resonant microsystem for direct measurement of liquid viscosity.
    Tiwari S; Dangi A; Pratap R
    Microsyst Nanoeng; 2023; 9():34. PubMed ID: 36969965
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A more comprehensive modeling of atomic force microscope cantilever.
    Mahdavi MH; Farshidianfar A; Tahani M; Mahdavi S; Dalir H
    Ultramicroscopy; 2008 Dec; 109(1):54-60. PubMed ID: 18848749
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Design and evaluation of an antiparallel coupled resonator for chemical sensor applications.
    Abe T; Kato H
    Anal Chem; 2007 Sep; 79(17):6804-6. PubMed ID: 17665878
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.