These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Computerized decision support system improves fluid resuscitation following severe burns: an original study. Salinas J; Chung KK; Mann EA; Cancio LC; Kramer GC; Serio-Melvin ML; Renz EM; Wade CE; Wolf SE Crit Care Med; 2011 Sep; 39(9):2031-8. PubMed ID: 21532472 [TBL] [Abstract][Full Text] [Related]
4. High-dose vitamin C infusion reduces fluid requirements in the resuscitation of burn-injured sheep. Dubick MA; Williams C; Elgjo GI; Kramer GC Shock; 2005 Aug; 24(2):139-44. PubMed ID: 16044084 [TBL] [Abstract][Full Text] [Related]
6. Closed-loop control of fluid therapy for treatment of hypovolemia. Kramer GC; Kinsky MP; Prough DS; Salinas J; Sondeen JL; Hazel-Scerbo ML; Mitchell CE J Trauma; 2008 Apr; 64(4 Suppl):S333-41. PubMed ID: 18385585 [TBL] [Abstract][Full Text] [Related]
7. Goal-Directed Fluid Resuscitation Protocol Based on Arterial Waveform Analysis of Major Burn Patients in a Mass Burn Casualty. Chiao HY; Chou CY; Tzeng YS; Wang CH; Chen SG; Dai NT Ann Plast Surg; 2018 Feb; 80(2S Suppl 1):S21-S25. PubMed ID: 29389698 [TBL] [Abstract][Full Text] [Related]
8. [Effects of early oral fluid resuscitation on organ functions and survival during shock stage in dogs with a 50% total body surface area full-thickness burn]. Hu S; Che JW; Wang HB; Yu Y; Tian YJ; Sheng ZY Zhonghua Yi Xue Za Zhi; 2008 Dec; 88(44):3149-52. PubMed ID: 19159601 [TBL] [Abstract][Full Text] [Related]
9. Fluid volumes infused during burn resuscitation 1980-2015: A quantitative review. Shah A; Pedraza I; Mitchell C; Kramer GC Burns; 2020 Feb; 46(1):52-57. PubMed ID: 31862276 [TBL] [Abstract][Full Text] [Related]
10. Burn resuscitation with two doses of 4 mL/kg hypertonic saline dextran provides sustained fluid sparing: a 48-hour prospective study in conscious sheep. Elgjo GI; Traber DL; Hawkins HK; Kramer GC J Trauma; 2000 Aug; 49(2):251-63; discussion 263-5. PubMed ID: 10963536 [TBL] [Abstract][Full Text] [Related]
11. [Effect of application of pulse contour cardiac output monitoring technology on delayed resuscitation of patients with extensive burn in a mass casualty]. Yang WX; Guo GH; Shen GL; Lin W; Zhao XY; Qi Q; Qian HG; Xie WZ; Wang ZX Zhonghua Shao Shang Za Zhi; 2016 Mar; 32(3):140-6. PubMed ID: 27030649 [TBL] [Abstract][Full Text] [Related]
12. Review of a fluid resuscitation protocol: "fluid creep" is not due to nursing error. Faraklas I; Cochran A; Saffle J J Burn Care Res; 2012; 33(1):74-83. PubMed ID: 22240507 [TBL] [Abstract][Full Text] [Related]
13. [Effect of carbachol on intestinal mucosa blood flow and absorption rate of glucose-electrolyte solution during enteral resuscitation for 50% total body surface area full-thickness burn injury in dog]. Hu S; Che JW; Du Y; Bao CM; Tian YJ; Wang L; Geng SJ; Wu J; Sheng ZY Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2008 Mar; 20(3):167-71. PubMed ID: 18328131 [TBL] [Abstract][Full Text] [Related]
14. Fluid therapy LiDCO controlled trial-optimization of volume resuscitation of extensively burned patients through noninvasive continuous real-time hemodynamic monitoring LiDCO. Tokarik M; Sjöberg F; Balik M; Pafcuga I; Broz L J Burn Care Res; 2013; 34(5):537-42. PubMed ID: 23511280 [TBL] [Abstract][Full Text] [Related]
15. [Clinical study on hematocrit used as a predictor for evaluation of resuscitation effect in the early shock stage after burn]. Zhao LP; Huang YS; He T; Hu XG Zhonghua Shao Shang Za Zhi; 2013 Jun; 29(3):235-8. PubMed ID: 24059946 [TBL] [Abstract][Full Text] [Related]