These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
196 related articles for article (PubMed ID: 16685881)
21. Accuracy and Precision of Head Motion Information in Multi-Channel Free Induction Decay Navigators for Magnetic Resonance Imaging. Babayeva M; Kober T; Knowles B; Herbst M; Meuli R; Zaitsev M; Krueger G IEEE Trans Med Imaging; 2015 Sep; 34(9):1879-89. PubMed ID: 25781624 [TBL] [Abstract][Full Text] [Related]
22. Volumetric navigators for prospective motion correction and selective reacquisition in neuroanatomical MRI. Tisdall MD; Hess AT; Reuter M; Meintjes EM; Fischl B; van der Kouwe AJ Magn Reson Med; 2012 Aug; 68(2):389-99. PubMed ID: 22213578 [TBL] [Abstract][Full Text] [Related]
25. PROMO: Real-time prospective motion correction in MRI using image-based tracking. White N; Roddey C; Shankaranarayanan A; Han E; Rettmann D; Santos J; Kuperman J; Dale A Magn Reson Med; 2010 Jan; 63(1):91-105. PubMed ID: 20027635 [TBL] [Abstract][Full Text] [Related]
26. Self-encoded marker for optical prospective head motion correction in MRI. Forman C; Aksoy M; Hornegger J; Bammer R Med Image Comput Comput Assist Interv; 2010; 13(Pt 1):259-66. PubMed ID: 20879239 [TBL] [Abstract][Full Text] [Related]
27. Optimizing the acceleration and resolution of three-dimensional fat image navigators for high-resolution motion correction at 7T. Gallichan D; Marques JP Magn Reson Med; 2017 Feb; 77(2):547-558. PubMed ID: 26877158 [TBL] [Abstract][Full Text] [Related]
28. Motion correction using an enhanced floating navigator and GRAPPA operations. Lin W; Huang F; Börnert P; Li Y; Reykowski A Magn Reson Med; 2010 Feb; 63(2):339-48. PubMed ID: 19918907 [TBL] [Abstract][Full Text] [Related]
29. Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses. Mitsouras D; Mulkern RV; Rybicki FJ Med Phys; 2006 Jan; 33(1):173-86. PubMed ID: 16485424 [TBL] [Abstract][Full Text] [Related]
30. Propagation of calibration errors in prospective motion correction using external tracking. Zahneisen B; Keating B; Ernst T Magn Reson Med; 2014 Aug; 72(2):381-8. PubMed ID: 24123287 [TBL] [Abstract][Full Text] [Related]
31. SEMAC-VAT and MSVAT-SPACE sequence strategies for metal artifact reduction in 1.5T magnetic resonance imaging. Ai T; Padua A; Goerner F; Nittka M; Gugala Z; Jadhav S; Trelles M; Johnson RF; Lindsey RW; Li X; Runge VM Invest Radiol; 2012 May; 47(5):267-76. PubMed ID: 22266987 [TBL] [Abstract][Full Text] [Related]
32. Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Aksoy M; Maclaren J; Bammer R Magn Reson Imaging; 2017 Jun; 39():44-52. PubMed ID: 28137627 [TBL] [Abstract][Full Text] [Related]
33. Referenceless reconstruction of spatiotemporally encoded imaging data: principles and applications to real-time MRI. Seginer A; Schmidt R; Leftin A; Solomon E; Frydman L Magn Reson Med; 2014 Dec; 72(6):1687-95. PubMed ID: 24420445 [TBL] [Abstract][Full Text] [Related]
34. Advanced three-dimensional tailored RF pulse for signal recovery in T2*-weighted functional magnetic resonance imaging. Yip CY; Fessler JA; Noll DC Magn Reson Med; 2006 Nov; 56(5):1050-9. PubMed ID: 17041911 [TBL] [Abstract][Full Text] [Related]