These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Development of dispersive XAFS system for analysis of time-resolved spatial distribution of electrode reaction. Katayama M; Miyahara R; Watanabe T; Yamagishi H; Yamashita S; Kizaki T; Sugawara Y; Inada Y J Synchrotron Radiat; 2015 Sep; 22(5):1227-32. PubMed ID: 26289274 [TBL] [Abstract][Full Text] [Related]
5. Rapid and sensitive XAFS using a tunable X-ray undulator at BL10XU of SPring-8. Oyanagi H; Ishii M; Lee CH; Saini NL; Kuwahara Y; Saito A; Izumi Y; Hashimoto H J Synchrotron Radiat; 2000 Mar; 7(Pt 2):89-94. PubMed ID: 16609179 [TBL] [Abstract][Full Text] [Related]
6. Development of micro-XANES mapping in the diamond anvil cell. Aquilanti G; Pascarelli S; Mathon O; Muñoz M; Narygina O; Dubrovinsky L J Synchrotron Radiat; 2009 May; 16(Pt 3):376-9. PubMed ID: 19395801 [TBL] [Abstract][Full Text] [Related]
7. Performance of a fuel cell optimized for in situX-ray absorption experiments. Principi E; Di Cicco A; Witkowska A; Marassi R J Synchrotron Radiat; 2007 May; 14(Pt 3):276-81. PubMed ID: 17435303 [TBL] [Abstract][Full Text] [Related]
8. Suppression of Bragg reflection glitches of a single-crystal diamond anvil cell by a polycapillary half-lens in high-pressure XAFS spectroscopy. Chen D; Dong J; Zhang X; Quan P; Liang Y; Hu T; Liu J; Wu X; Zhang Q; Li Y J Synchrotron Radiat; 2013 Mar; 20(Pt 2):243-8. PubMed ID: 23412480 [TBL] [Abstract][Full Text] [Related]
11. Bent crystal Laue analyser combined with total reflection fluorescence X-ray absorption fine structure (BCLA + TRF-XAFS) and its application to surface studies. Wakisaka Y; Hu B; Kido D; Al Rashid MH; Chen W; Dong K; Wada T; Bharate B; Yuan Q; Mukai S; Takeichi Y; Takakusagi S; Asakura K J Synchrotron Radiat; 2020 Nov; 27(Pt 6):1618-1625. PubMed ID: 33147187 [TBL] [Abstract][Full Text] [Related]
12. Characteristics of a tapered undulator for the X-ray absorption fine-structure technique at PLS-II. Sung NE; Lee IJ; Jeong SH; Kang SW J Synchrotron Radiat; 2014 Nov; 21(Pt 6):1282-7. PubMed ID: 25343796 [TBL] [Abstract][Full Text] [Related]
13. KMC-1: a high resolution and high flux soft x-ray beamline at BESSY. Schaefers F; Mertin M; Gorgoi M Rev Sci Instrum; 2007 Dec; 78(12):123102. PubMed ID: 18163715 [TBL] [Abstract][Full Text] [Related]
14. X-ray Optics of a Dynamical Sagittal-Focusing Monochromator on the GILDA Beamline at the ESRF. Pascarelli S; Boscherini F; D'Acapito F; Hrdy J; Meneghini C; Mobilio S J Synchrotron Radiat; 1996 Jul; 3(Pt 4):147-55. PubMed ID: 16702672 [TBL] [Abstract][Full Text] [Related]
15. A fast energy-dispersive multi-element detector for X-ray absorption spectroscopy. Welter E; Hansen K; Reckleben C; Diehl I J Synchrotron Radiat; 2009 Mar; 16(Pt 2):293-8. PubMed ID: 19240342 [TBL] [Abstract][Full Text] [Related]
16. Achievements in high-pressure science at the high-brilliance energy-dispersive X-ray absorption spectrometer of ESRF, ID24. Aquilanti G; Mathon O; Pascarelli S J Synchrotron Radiat; 2009 Nov; 16(Pt 6):699-706. PubMed ID: 19844002 [TBL] [Abstract][Full Text] [Related]
17. A micro-focusing and high-flux-throughput beamline design using a bending magnet for microscopic XAFS at the High Energy Photon Source. Tang K; Zheng L; Zhao YD; Liu SH; Ma CY; Dong YH J Synchrotron Radiat; 2019 Sep; 26(Pt 5):1835-1842. PubMed ID: 31490178 [TBL] [Abstract][Full Text] [Related]
18. A new method for polychromatic X-ray μLaue diffraction on a Cu pillar using an energy-dispersive pn-junction charge-coupled device. Abboud A; Kirchlechner C; Send S; Micha JS; Ulrich O; Pashniak N; Strüder L; Keckes J; Pietsch U Rev Sci Instrum; 2014 Nov; 85(11):113901. PubMed ID: 25430118 [TBL] [Abstract][Full Text] [Related]