These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

302 related articles for article (PubMed ID: 16696991)

  • 21. High-performance liquid chromatographic stationary phases based on poly(methyloctylsiloxane) immobilized on silica. II. Chromatographic evaluation.
    Tonhi E; Collins KE; Collins CH
    J Chromatogr A; 2002 Mar; 948(1-2):109-19. PubMed ID: 12831188
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effects of pH and temperature on the chromatographic performance and stability of immobilized poly(methyloctylsiloxane) stationary phases.
    Borges EM; Collins CH
    J Chromatogr A; 2012 Mar; 1227():174-80. PubMed ID: 22277182
    [TBL] [Abstract][Full Text] [Related]  

  • 23. High-performance liquid chromatographic stationary phases based on poly(methyloctylsiloxane) immobilized on silica. I. Physical and chemical characterizations.
    Tonhi E; Bachmann S; Albert K; Jardim IC; Collins KE; Collins CH
    J Chromatogr A; 2002 Mar; 948(1-2):97-107. PubMed ID: 12831187
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Immobilized metallacarborane as a new type of stationary phase for high performance liquid chromatography.
    Sykora D; Vosmanska M; Matejka P; Kral V
    J Chromatogr A; 2011 May; 1218(20):3029-36. PubMed ID: 21497356
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Synthesis, self-assembling properties, and atom transfer radical polymerization of an alkylated L-phenylalanine-derived monomeric organogel from silica: a new approach to prepare packing materials for high-performance liquid chromatography.
    Rahman MM; Czaun M; Takafuji M; Ihara H
    Chemistry; 2008; 14(4):1312-21. PubMed ID: 18033705
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Preparation and characterization of a new microwave immobilized poly(2-phenylpropyl)methylsiloxane stationary phase for reversed phase high-performance liquid chromatography.
    Begnini FR; Jardim IC
    J Chromatogr A; 2013 Jul; 1297():113-22. PubMed ID: 23726242
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Influence of vinyl monomers and temperature on immobilization of cellulose 3,5-dimethylphenylcarbamate onto silica gel as chiral stationary phases for high-performance liquid chromatography.
    Chen XM; Yamamoto C; Okamoto Y
    J Chromatogr A; 2006 Feb; 1104(1-2):62-8. PubMed ID: 16359692
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of a new polymeric stationary phase with reversed-phase properties for high temperature liquid chromatography.
    Vanhoenacker G; Dos Santos Pereira A; Kotsuka T; Cabooter D; Desmet G; Sandra P
    J Chromatogr A; 2010 May; 1217(19):3217-22. PubMed ID: 19825499
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Self-immobilization and/or thermal treatment for preparing silica-poly(methyloctylsiloxane) stationary phases.
    Bottoli CB; Vigna CR; Fischer G; Albert K; Collins KE; Collins CH
    J Chromatogr A; 2004 Mar; 1030(1-2):217-23. PubMed ID: 15043272
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Titania-based stationary phase in separation of ondansetron and its related compounds.
    Zizkovský V; Kucera R; Klimes J; Dohnal J
    J Chromatogr A; 2008 May; 1189(1-2):83-91. PubMed ID: 18190922
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Preparation and evaluation of a silica-based 1-alkyl-3-(propyl-3-sulfonate) imidazolium zwitterionic stationary phase for high-performance liquid chromatography.
    Qiu H; Jiang Q; Wei Z; Wang X; Liu X; Jiang S
    J Chromatogr A; 2007 Sep; 1163(1-2):63-9. PubMed ID: 17582425
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Preparation of monolithic silica columns for high-performance liquid chromatography.
    Núñez O; Nakanishi K; Tanaka N
    J Chromatogr A; 2008 May; 1191(1-2):231-52. PubMed ID: 18313061
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Preparation and characterization of phosphatidylcholine-coated zirconia-magnesia stationary phase for artificial membrane chromatography.
    Zhang W; Hu Z; Feng Y; Da S
    J Sep Sci; 2010 Oct; 33(19):2990-7. PubMed ID: 20812229
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Thermally responsive chromatographic materials using functional polymers.
    Kanazawa H
    J Sep Sci; 2007 Jul; 30(11):1646-56. PubMed ID: 17623446
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A novel octadecylsilane functionalized graphene oxide/silica composite stationary phase for high performance liquid chromatography.
    Liang X; Wang S; Liu S; Liu X; Jiang S
    J Sep Sci; 2012 Aug; 35(16):2003-9. PubMed ID: 22899638
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Chemical stability of reversed phase high performance liquid chromatography silica under sodium hydroxide regeneration conditions.
    Pettersson SW; Collet E; Andersson U
    J Chromatogr A; 2007 Feb; 1142(1):93-7. PubMed ID: 16999967
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Novel reversed-phase high-performance liquid chromatography stationary phase with oligo(ethylene glycol) "click" to silica.
    Guo Z; Liu Y; Xu J; Xu Q; Xue X; Zhang F; Ke Y; Liang X; Lei A
    J Chromatogr A; 2008 May; 1191(1-2):78-82. PubMed ID: 18082752
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Poly(1-allylimidazole)-grafted silica, a new specific stationary phase for reversed-phase and anion-exchange liquid chromatography.
    Sun M; Qiu H; Wang L; Liu X; Jiang S
    J Chromatogr A; 2009 May; 1216(18):3904-9. PubMed ID: 19296959
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Chromatographic comparison of bupivacaine imprinted polymers prepared in crushed monolith, microsphere, silica-based composite and capillary monolith formats.
    Oxelbark J; Legido-Quigley C; Aureliano CS; Titirici MM; Schillinger E; Sellergren B; Courtois J; Irgum K; Dambies L; Cormack PA; Sherrington DC; De Lorenzi E
    J Chromatogr A; 2007 Aug; 1160(1-2):215-26. PubMed ID: 17559860
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effects in high-performance liquid chromatography of a high pH in the mobile phase on poly(methyloctylsiloxane) immobilized by gamma-radiation on titanium-grafted silica.
    Silva RB; Collins KE; Collins CH
    J Chromatogr A; 2000 Feb; 869(1-2):137-41. PubMed ID: 10720232
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.