BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

237 related articles for article (PubMed ID: 16701852)

  • 1. Electrochemical release testing of nickel-titanium orthodontic wires in artificial saliva using thin layer activation.
    Cioffi M; Gilliland D; Ceccone G; Chiesa R; Cigada A
    Acta Biomater; 2005 Nov; 1(6):717-24. PubMed ID: 16701852
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires.
    Walker MP; White RJ; Kula KS
    Am J Orthod Dentofacial Orthop; 2005 Jun; 127(6):662-9. PubMed ID: 15953890
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Corrosion behavior of shape memory, superelastic, and nonsuperelastic nickel-titanium-based orthodontic wires at various temperatures.
    Pun DK; Berzins DW
    Dent Mater; 2008 Feb; 24(2):221-7. PubMed ID: 17624421
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of fluoridated mouthwashes on corrosion resistance of orthodontics wires.
    Schiff N; Grosgogeat B; Lissac M; Dalard F
    Biomaterials; 2004 Aug; 25(19):4535-42. PubMed ID: 15120498
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Corrosion susceptibility and nickel release of nickel titanium wires during clinical application.
    Petoumeno E; Kislyuk M; Hoederath H; Keilig L; Bourauel C; Jäger A
    J Orofac Orthop; 2008 Nov; 69(6):411-23. PubMed ID: 19169638
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electrochemical studies of the corrosion behaviour of titanium and the Ti-6Al-4V alloy using electrochemical impedance spectroscopy.
    Grosgogeat B; Boinet M; Dalard F; Lissac M
    Biomed Mater Eng; 2004; 14(3):323-31. PubMed ID: 15299244
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Surface corrosion and fracture resistance of two nickel-titanium-based archwires induced by fluoride, pH, and thermocycling. An in vitro comparative study.
    Perinetti G; Contardo L; Ceschi M; Antoniolli F; Franchi L; Baccetti T; Di Lenarda R
    Eur J Orthod; 2012 Feb; 34(1):1-9. PubMed ID: 21041836
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Nickel concentration in the saliva of patients with nickel-titanium orthodontic appliances.
    Petoumenou E; Arndt M; Keilig L; Reimann S; Hoederath H; Eliades T; Jäger A; Bourauel C
    Am J Orthod Dentofacial Orthop; 2009 Jan; 135(1):59-65. PubMed ID: 19121502
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use.
    Wang QY; Zheng YF
    Dent Mater; 2008 Sep; 24(9):1207-11. PubMed ID: 18336899
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of Pt and Pd alloying additions on the corrosion behavior of titanium in fluoride-containing environments.
    Nakagawa M; Matono Y; Matsuya S; Udoh K; Ishikawa K
    Biomaterials; 2005 May; 26(15):2239-46. PubMed ID: 15585225
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reliability performance of titanium sputter coated Ni-Ti arch wires: mechanical performance and nickel release evaluation.
    Anuradha P; Varma NK; Balakrishnan A
    Biomed Mater Eng; 2015; 26(1-2):67-77. PubMed ID: 26484557
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface characterizations and corrosion resistance of nickel-titanium orthodontic archwires in artificial saliva of various degrees of acidity.
    Huang HH
    J Biomed Mater Res A; 2005 Sep; 74(4):629-39. PubMed ID: 16025472
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stress corrosion cracking of NiTi in artificial saliva.
    Wang J; Li N; Rao G; Han EH; Ke W
    Dent Mater; 2007 Feb; 23(2):133-7. PubMed ID: 16466784
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Variation in corrosion resistance of nickel-titanium wires from different manufacturers.
    Huang HH
    Angle Orthod; 2005 Jul; 75(4):661-5. PubMed ID: 16097238
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of recycling on the mechanical properties and the surface topography of nickel-titanium alloy wires.
    Lee SH; Chang YI
    Am J Orthod Dentofacial Orthop; 2001 Dec; 120(6):654-63. PubMed ID: 11742311
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of mucine, IgA, urea, and lysozyme on the corrosion behavior of various non-precious dental alloys and pure titanium in artificial saliva.
    Bilhan H; Bilgin T; Cakir AF; Yuksel B; Von Fraunhofer JA
    J Biomater Appl; 2007 Nov; 22(3):197-221. PubMed ID: 17255155
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Corrosion resistance of three orthodontic brackets: a comparative study of three fluoride mouthwashes.
    Schiff N; Dalard F; Lissac M; Morgon L; Grosgogeat B
    Eur J Orthod; 2005 Dec; 27(6):541-9. PubMed ID: 16049037
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hydrogen embrittlement of work-hardened Ni-Ti alloy in fluoride solutions.
    Yokoyama K; Kaneko K; Ogawa T; Moriyama K; Asaoka K; Sakai J
    Biomaterials; 2005 Jan; 26(1):101-8. PubMed ID: 15193885
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of fluoride and chloride on corrosion behavior of NiTi orthodontic wires.
    Li X; Wang J; Han EH; Ke W
    Acta Biomater; 2007 Sep; 3(5):807-15. PubMed ID: 17467350
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.