234 related articles for article (PubMed ID: 16701927)
1. Assessments of different kinds of stems by experiments and FEM analysis: appropriate stress distribution on a hip prosthesis.
Sakai R; Itoman M; Mabuchi K
Clin Biomech (Bristol, Avon); 2006 Oct; 21(8):826-33. PubMed ID: 16701927
[TBL] [Abstract][Full Text] [Related]
2. Assessment of the fixation stiffness of some femoral stems of different designs.
Sakai R; Kanai N; Itoman M; Mabuchi K
Clin Biomech (Bristol, Avon); 2006 May; 21(4):370-8. PubMed ID: 16431001
[TBL] [Abstract][Full Text] [Related]
3. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
[TBL] [Abstract][Full Text] [Related]
4. Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems.
Decking R; Puhl W; Simon U; Claes LE
Clin Biomech (Bristol, Avon); 2006 Jun; 21(5):495-501. PubMed ID: 16457913
[TBL] [Abstract][Full Text] [Related]
5. Can the rasp be used to predict intra-operatively the primary stability that can be achieved by press-fitting the stem in cementless hip arthroplasty?
Varini E; Cristofolini L; Traina F; Viceconti M; Toni A
Clin Biomech (Bristol, Avon); 2008 May; 23(4):408-14. PubMed ID: 18068878
[TBL] [Abstract][Full Text] [Related]
6. The contour of cementless femoral stem has minor effect on initial periprosthetic von Mises stress distribution. A 3-dimensional finite element analysis.
Hu KZ; Zhang XL; Wang CT; Ji WT
Saudi Med J; 2009 Jul; 30(7):947-51. PubMed ID: 19618013
[TBL] [Abstract][Full Text] [Related]
7. Subject specific finite element analysis of implant stability for a cementless femoral stem.
Pettersen SH; Wik TS; Skallerud B
Clin Biomech (Bristol, Avon); 2009 Jul; 24(6):480-7. PubMed ID: 19368993
[TBL] [Abstract][Full Text] [Related]
8. Primary stability of an anatomical cementless hip stem: a statistical analysis.
Viceconti M; Brusi G; Pancanti A; Cristofolini L
J Biomech; 2006; 39(7):1169-79. PubMed ID: 15927191
[TBL] [Abstract][Full Text] [Related]
9. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
Kovanda M; Havlícek V; Hudec J
Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
[TBL] [Abstract][Full Text] [Related]
10. Rotational stability based on displacements obtained by simulation and measurement when torsion loading is applied to hip stems.
Sakai R; Iwama A; Itoman M; Mabuchi K
J Orthop Sci; 2008 May; 13(3):248-54. PubMed ID: 18528659
[TBL] [Abstract][Full Text] [Related]
11. [Three-dimensional finite element analysis of bone stress distribution around the hip joint prosthesis with stepped stem].
Tan R; Fan H; Wu F; Chen J; Luo J; Zhang X
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Aug; 28(4):732-6. PubMed ID: 21936371
[TBL] [Abstract][Full Text] [Related]
12. Primary stability and strain distribution of cementless hip stems as a function of implant design.
Bieger R; Ignatius A; Decking R; Claes L; Reichel H; Dürselen L
Clin Biomech (Bristol, Avon); 2012 Feb; 27(2):158-64. PubMed ID: 21889243
[TBL] [Abstract][Full Text] [Related]
13. Relation between subject-specific hip joint loading, stress distribution in the proximal femur and bone mineral density changes after total hip replacement.
Jonkers I; Sauwen N; Lenaerts G; Mulier M; Van der Perre G; Jaecques S
J Biomech; 2008 Dec; 41(16):3405-13. PubMed ID: 19019372
[TBL] [Abstract][Full Text] [Related]
14. [Study on design method for the individual anatomical hip joint endoprosthesis].
Gong X; Kang L; Wang J
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Feb; 25(1):92-6. PubMed ID: 18435265
[TBL] [Abstract][Full Text] [Related]
15. Stress analysis of the interface between cervical vertebrae end plates and the Bryan, Prestige LP, and ProDisc-C cervical disc prostheses: an in vivo image-based finite element study.
Lin CY; Kang H; Rouleau JP; Hollister SJ; Marca FL
Spine (Phila Pa 1976); 2009 Jul; 34(15):1554-60. PubMed ID: 19564765
[TBL] [Abstract][Full Text] [Related]
16. Design and test of hip stem for medullary revascularization.
Yang CT; Wei HW; Kao HC; Cheng CK
Med Eng Phys; 2009 Oct; 31(8):994-1001. PubMed ID: 19581119
[TBL] [Abstract][Full Text] [Related]
17. Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: a biomechanical model.
Bellini CM; Galbusera F; Ceroni RG; Raimondi MT
Med Eng Phys; 2007 Mar; 29(2):175-81. PubMed ID: 16569508
[TBL] [Abstract][Full Text] [Related]
18. Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement.
Kluess D; Martin H; Mittelmeier W; Schmitz KP; Bader R
Med Eng Phys; 2007 May; 29(4):465-71. PubMed ID: 16901743
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: an in vitro and finite element analysis.
Completo A; Rego A; Fonseca F; Ramos A; Relvas C; Simões JA
Clin Biomech (Bristol, Avon); 2010 Feb; 25(2):159-65. PubMed ID: 19944503
[TBL] [Abstract][Full Text] [Related]
20. [Finite element analysis of changes in femoral stresses after elite total hip arthroplasty].
He RX; Luo YM; Yan SG; Wu HB
Zhonghua Yi Xue Za Zhi; 2004 Sep; 84(18):1549-53. PubMed ID: 15500718
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]