BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

234 related articles for article (PubMed ID: 16701927)

  • 1. Assessments of different kinds of stems by experiments and FEM analysis: appropriate stress distribution on a hip prosthesis.
    Sakai R; Itoman M; Mabuchi K
    Clin Biomech (Bristol, Avon); 2006 Oct; 21(8):826-33. PubMed ID: 16701927
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of the fixation stiffness of some femoral stems of different designs.
    Sakai R; Kanai N; Itoman M; Mabuchi K
    Clin Biomech (Bristol, Avon); 2006 May; 21(4):370-8. PubMed ID: 16431001
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems.
    Decking R; Puhl W; Simon U; Claes LE
    Clin Biomech (Bristol, Avon); 2006 Jun; 21(5):495-501. PubMed ID: 16457913
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Can the rasp be used to predict intra-operatively the primary stability that can be achieved by press-fitting the stem in cementless hip arthroplasty?
    Varini E; Cristofolini L; Traina F; Viceconti M; Toni A
    Clin Biomech (Bristol, Avon); 2008 May; 23(4):408-14. PubMed ID: 18068878
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The contour of cementless femoral stem has minor effect on initial periprosthetic von Mises stress distribution. A 3-dimensional finite element analysis.
    Hu KZ; Zhang XL; Wang CT; Ji WT
    Saudi Med J; 2009 Jul; 30(7):947-51. PubMed ID: 19618013
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Subject specific finite element analysis of implant stability for a cementless femoral stem.
    Pettersen SH; Wik TS; Skallerud B
    Clin Biomech (Bristol, Avon); 2009 Jul; 24(6):480-7. PubMed ID: 19368993
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Primary stability of an anatomical cementless hip stem: a statistical analysis.
    Viceconti M; Brusi G; Pancanti A; Cristofolini L
    J Biomech; 2006; 39(7):1169-79. PubMed ID: 15927191
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rotational stability based on displacements obtained by simulation and measurement when torsion loading is applied to hip stems.
    Sakai R; Iwama A; Itoman M; Mabuchi K
    J Orthop Sci; 2008 May; 13(3):248-54. PubMed ID: 18528659
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Three-dimensional finite element analysis of bone stress distribution around the hip joint prosthesis with stepped stem].
    Tan R; Fan H; Wu F; Chen J; Luo J; Zhang X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Aug; 28(4):732-6. PubMed ID: 21936371
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Primary stability and strain distribution of cementless hip stems as a function of implant design.
    Bieger R; Ignatius A; Decking R; Claes L; Reichel H; Dürselen L
    Clin Biomech (Bristol, Avon); 2012 Feb; 27(2):158-64. PubMed ID: 21889243
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Relation between subject-specific hip joint loading, stress distribution in the proximal femur and bone mineral density changes after total hip replacement.
    Jonkers I; Sauwen N; Lenaerts G; Mulier M; Van der Perre G; Jaecques S
    J Biomech; 2008 Dec; 41(16):3405-13. PubMed ID: 19019372
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Study on design method for the individual anatomical hip joint endoprosthesis].
    Gong X; Kang L; Wang J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Feb; 25(1):92-6. PubMed ID: 18435265
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stress analysis of the interface between cervical vertebrae end plates and the Bryan, Prestige LP, and ProDisc-C cervical disc prostheses: an in vivo image-based finite element study.
    Lin CY; Kang H; Rouleau JP; Hollister SJ; Marca FL
    Spine (Phila Pa 1976); 2009 Jul; 34(15):1554-60. PubMed ID: 19564765
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Design and test of hip stem for medullary revascularization.
    Yang CT; Wei HW; Kao HC; Cheng CK
    Med Eng Phys; 2009 Oct; 31(8):994-1001. PubMed ID: 19581119
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: a biomechanical model.
    Bellini CM; Galbusera F; Ceroni RG; Raimondi MT
    Med Eng Phys; 2007 Mar; 29(2):175-81. PubMed ID: 16569508
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of femoral head size on impingement, dislocation and stress distribution in total hip replacement.
    Kluess D; Martin H; Mittelmeier W; Schmitz KP; Bader R
    Med Eng Phys; 2007 May; 29(4):465-71. PubMed ID: 16901743
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: an in vitro and finite element analysis.
    Completo A; Rego A; Fonseca F; Ramos A; Relvas C; Simões JA
    Clin Biomech (Bristol, Avon); 2010 Feb; 25(2):159-65. PubMed ID: 19944503
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Finite element analysis of changes in femoral stresses after elite total hip arthroplasty].
    He RX; Luo YM; Yan SG; Wu HB
    Zhonghua Yi Xue Za Zhi; 2004 Sep; 84(18):1549-53. PubMed ID: 15500718
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.