These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

219 related articles for article (PubMed ID: 16706311)

  • 21. Adhesive bonding of super-elastic titanium-nickel alloy castings with a phosphate metal conditioner and an acrylic adhesive.
    Matsumura H; Tanoue N; Yanagida H; Atsuta M; Koike M; Yoneyama T
    J Oral Rehabil; 2003 Jun; 30(6):653-8. PubMed ID: 12787464
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of copper on the localized corrosion resistance of Ni-Ti shape memory alloy.
    Rondelli G; Vicentini B
    Biomaterials; 2002 Feb; 23(3):639-44. PubMed ID: 11771683
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Length-dependent corrosion behavior, Ni
    Hang R; Liu Y; Bai L; Zhang X; Huang X; Jia H; Tang B
    Mater Sci Eng C Mater Biol Appl; 2018 Aug; 89():1-7. PubMed ID: 29752078
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation by electrochemical tests of the passive film stability of equiatomic Ni-Ti alloy also in presence of stress-induced martensite.
    Rondelli G; Vicentini B
    J Biomed Mater Res; 2000 Jul; 51(1):47-54. PubMed ID: 10813744
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [The effect on anti-acid corrosion resistance of Ni-Cr alloy coating titanium].
    Hu B; Zhang FQ
    Shanghai Kou Qiang Yi Xue; 2003 Apr; 12(2):132-5. PubMed ID: 14661520
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Porous TiO₂ surface formed on nickel-titanium alloy by plasma electrolytic oxidation: a prospective polymer-free reservoir for drug eluting stent applications.
    Huan Z; Fratila-Apachitei LE; Apachitei I; Duszczyk J
    J Biomed Mater Res B Appl Biomater; 2013 Jul; 101(5):700-8. PubMed ID: 23359528
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires.
    Rondelli G; Vicentini B
    Biomaterials; 1999 Apr; 20(8):785-92. PubMed ID: 10353661
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The effect of mucin, fibrinogen and IgG on the corrosion behaviour of Ni-Ti alloy and stainless steel.
    Chao Z; Yaomu X; Chufeng L; Conghua L
    Biometals; 2017 Jun; 30(3):367-377. PubMed ID: 28343289
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution.
    Montero-Ocampo C; Lopez H; Salinas Rodriguez A
    J Biomed Mater Res; 1996 Dec; 32(4):583-91. PubMed ID: 8953148
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Reliability performance of titanium sputter coated Ni-Ti arch wires: mechanical performance and nickel release evaluation.
    Anuradha P; Varma NK; Balakrishnan A
    Biomed Mater Eng; 2015; 26(1-2):67-77. PubMed ID: 26484557
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Study of blood compatibility on TiO2 coated biomedical Ni-Ti shape memory alloy].
    Gao S; Zhai Y; Hu J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Oct; 28(5):968-71, 1000. PubMed ID: 22097265
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Corrosion resistance of Co-Cr, Ni-Cr, Ni-Cr-Ti alloy in artificial saliva].
    Sun P; Lu Y; Chen S
    Shanghai Kou Qiang Yi Xue; 2007 Dec; 16(6):652-6. PubMed ID: 18278423
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Influence of the microstructure on electrochemical corrosion and nickel release in NiTi orthodontic archwires.
    Briceño J; Romeu A; Espinar E; Llamas JM; Gil FJ
    Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):4989-93. PubMed ID: 24094215
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Corrosion resistance and mechanical properties of titanium nitride plating on orthodontic wires.
    Sugisawa H; Kitaura H; Ueda K; Kimura K; Ishida M; Ochi Y; Kishikawa A; Ogawa S; Takano-Yamamoto T
    Dent Mater J; 2018 Mar; 37(2):286-292. PubMed ID: 29109336
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The intrinsically high pitting corrosion resistance of mechanically polished nitinol in simulated physiological solutions.
    Bai Z; Rotermund HH
    J Biomed Mater Res B Appl Biomater; 2011 Oct; 99(1):1-13. PubMed ID: 21648066
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Corrosion and wear-corrosion behavior of NiTi modified by plasma source ion implantation.
    Tan L; Dodd RA; Crone WC
    Biomaterials; 2003 Oct; 24(22):3931-9. PubMed ID: 12834588
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Experimental Investigation of the Biofunctional Properties of Nickel-Titanium Alloys Depending on the Type of Production.
    Miličić Lazić M; Majerič P; Lazić V; Milašin J; Jakšić M; Trišić D; Radović K
    Molecules; 2022 Mar; 27(6):. PubMed ID: 35335323
    [TBL] [Abstract][Full Text] [Related]  

  • 38. On the in vitro biocompatibility of Elgiloy, a co-based alloy, compared to two titanium alloys.
    Es-Souni M; Fischer-Brandies H; Es-Souni M
    J Orofac Orthop; 2003 Jan; 64(1):16-26. PubMed ID: 12557104
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Effect of fluoride ion on corrosion of two dental titanium alloys].
    Cao BW; Chen L
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2010 Jun; 28(3):261-4. PubMed ID: 20635653
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Cytotoxicity and oxidative stress induced by nickel and titanium ions from dental alloys on cells of gastrointestinal tract.
    Rincic Mlinaric M; Durgo K; Katic V; Spalj S
    Toxicol Appl Pharmacol; 2019 Nov; 383():114784. PubMed ID: 31628918
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.