These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Charge-injection-device performance in the high-energy-neutron environment of laser-fusion experiments. Marshall FJ; DeHaas T; Glebov VY Rev Sci Instrum; 2010 Oct; 81(10):10E503. PubMed ID: 21034031 [TBL] [Abstract][Full Text] [Related]
5. A pixel detector-based single photon-counting system as fast spectrometer for diagnostic X-ray beams. Carpentieri C; Bisogni MG; Del Guerra A; Delogu P; Fantacci ME; Fogli J; Marchi A; Marzulli V; Rosso V; Stefanini A; Tofani A Radiat Prot Dosimetry; 2008; 129(1-3):119-22. PubMed ID: 18487616 [TBL] [Abstract][Full Text] [Related]
6. Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study. Shikhaliev PM Phys Med Biol; 2005 Dec; 50(24):5813-27. PubMed ID: 16333157 [TBL] [Abstract][Full Text] [Related]
7. Application of a pnCCD in X-ray diffraction: a three-dimensional X-ray detector. Leitenberger W; Hartmann R; Pietsch U; Andritschke R; Starke I; Strüder L J Synchrotron Radiat; 2008 Sep; 15(Pt 5):449-57. PubMed ID: 18728315 [TBL] [Abstract][Full Text] [Related]
8. Invited article: the fast readout low noise camera as a versatile x-ray detector for time resolved dispersive extended x-ray absorption fine structure and diffraction studies of dynamic problems in materials science, chemistry, and catalysis. Labiche JC; Mathon O; Pascarelli S; Newton MA; Ferre GG; Curfs C; Vaughan G; Homs A; Carreiras DF Rev Sci Instrum; 2007 Sep; 78(9):091301. PubMed ID: 17902940 [TBL] [Abstract][Full Text] [Related]
9. A tunable multicolour 'rainbow' filter for improved stress and dislocation density field mapping in polycrystals using X-ray Laue microdiffraction. Robach O; Micha JS; Ulrich O; Geaymond O; Sicardy O; Härtwig J; Rieutord F Acta Crystallogr A; 2013 Mar; 69(Pt 2):164-70. PubMed ID: 23403967 [TBL] [Abstract][Full Text] [Related]
10. Detectors for the future of X-ray imaging. Aslund M; Fredenberg E; Telman M; Danielsson M Radiat Prot Dosimetry; 2010; 139(1-3):327-33. PubMed ID: 20207749 [TBL] [Abstract][Full Text] [Related]
11. K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors. Roessl E; Proksa R Phys Med Biol; 2007 Aug; 52(15):4679-96. PubMed ID: 17634657 [TBL] [Abstract][Full Text] [Related]
14. High-energy transmission Laue micro-beam X-ray diffraction: a probe for intra-granular lattice orientation and elastic strain in thicker samples. Hofmann F; Song X; Abbey B; Jun TS; Korsunsky AM J Synchrotron Radiat; 2012 May; 19(Pt 3):307-18. PubMed ID: 22514163 [TBL] [Abstract][Full Text] [Related]
15. Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays. Shikhaliev PM Phys Med Biol; 2012 Mar; 57(6):1595-615. PubMed ID: 22398007 [TBL] [Abstract][Full Text] [Related]
16. A new method for polychromatic X-ray μLaue diffraction on a Cu pillar using an energy-dispersive pn-junction charge-coupled device. Abboud A; Kirchlechner C; Send S; Micha JS; Ulrich O; Pashniak N; Strüder L; Keckes J; Pietsch U Rev Sci Instrum; 2014 Nov; 85(11):113901. PubMed ID: 25430118 [TBL] [Abstract][Full Text] [Related]
17. X-ray Laue Diffraction from Protein Crystals. Moffat K; Szebenyi D; Bilderback D Science; 1984 Mar; 223(4643):1423-5. PubMed ID: 17746054 [TBL] [Abstract][Full Text] [Related]
18. Energy-dispersive Laue diffraction by means of a pnCCD detector coupled to a CsI(Tl) scintillator using ultra-hard X-ray synchrotron radiation. Shokr M; Tosson A; Abboud A; Algashi A; Schlosser D; Hartmann R; Klaus M; Genzel C; Strüder L; Pietsch U J Synchrotron Radiat; 2019 Sep; 26(Pt 5):1612-1620. PubMed ID: 31490151 [TBL] [Abstract][Full Text] [Related]
19. Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography. Roessl E; Brendel B; Engel KJ; Schlomka JP; Thran A; Proksa R IEEE Trans Med Imaging; 2011 Sep; 30(9):1678-90. PubMed ID: 21507770 [TBL] [Abstract][Full Text] [Related]
20. Detective quantum efficiency, modulation transfer function and energy resolution comparison between CdTe and silicon sensors bump-bonded to XPAD3S. Medjoubi K; Bucaille T; Hustache S; Bérar JF; Boudet N; Clemens JC; Delpierre P; Dinkespiler B J Synchrotron Radiat; 2010 Jul; 17(4):486-95. PubMed ID: 20567081 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]