BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

258 related articles for article (PubMed ID: 16715479)

  • 1. Simultaneous determination of low levels of methotrexate and cyclophosphamide in human urine by micro liquid chromatography/electrospray ionization tandem mass spectrometry.
    Barbieri A; Sabatini L; Indiveri P; Bonfiglioli R; Lodi V; Violante FS
    Rapid Commun Mass Spectrom; 2006; 20(12):1889-93. PubMed ID: 16715479
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous determination of cyclophosphamide, ifosfamide, doxorubicin, epirubicin and daunorubicin in human urine using high-performance liquid chromatography/electrospray ionization tandem mass spectrometry: bioanalytical method validation.
    Sottani C; Rinaldi P; Leoni E; Poggi G; Teragni C; Delmonte A; Minoia C
    Rapid Commun Mass Spectrom; 2008 Sep; 22(17):2645-59. PubMed ID: 18666202
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Highly sensitive high-performance liquid chromatography/selective reaction monitoring mass spectrometry method for the determination of cyclophosphamide and ifosfamide in urine of health care workers exposed to antineoplastic agents.
    Sottani C; Tranfo G; Faranda P; Minoia C
    Rapid Commun Mass Spectrom; 2005; 19(19):2794-800. PubMed ID: 16144038
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new high-performance liquid chromatographic/electrospray ionization tandem mass spectrometric method for the simultaneous determination of cyclophosphamide, methotrexate and 5-fluorouracil as markers of surface contamination for occupational exposure monitoring.
    Sabatini L; Barbieri A; Tosi M; Violante FS
    J Mass Spectrom; 2005 May; 40(5):669-74. PubMed ID: 15739158
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Trace determination of anthracyclines in urine: a new high-performance liquid chromatography/tandem mass spectrometry method for assessing exposure of hospital personnel.
    Sottani C; Tranfo G; Bettinelli M; Faranda P; Spagnoli M; Minoia C
    Rapid Commun Mass Spectrom; 2004; 18(20):2426-36. PubMed ID: 15386628
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A method for routine quantitation of urinary 8-hydroxy-2'-deoxyguanosine based on solid-phase extraction and micro-high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.
    Sabatini L; Barbieri A; Tosi M; Roda A; Violante FS
    Rapid Commun Mass Spectrom; 2005; 19(2):147-52. PubMed ID: 15593068
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous determination of gemcitabine, taxol, cyclophosphamide and ifosfamide in wipe samples by high-performance liquid chromatography/tandem mass spectrometry: protocol of validation and uncertainty of measurement.
    Sottani C; Turci R; Schierl R; Gaggeri R; Barbieri A; Violante FS; Minoia C
    Rapid Commun Mass Spectrom; 2007; 21(7):1289-96. PubMed ID: 17340557
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous determination of mercapturic acids derived from ethylene oxide (HEMA), propylene oxide (2-HPMA), acrolein (3-HPMA), acrylamide (AAMA) and N,N-dimethylformamide (AMCC) in human urine using liquid chromatography/tandem mass spectrometry.
    Schettgen T; Musiol A; Kraus T
    Rapid Commun Mass Spectrom; 2008 Sep; 22(17):2629-38. PubMed ID: 18666198
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of bezafibrate, methotrexate, cyclophosphamide, orlistat and enalapril in waste and surface waters using on-line solid-phase extraction liquid chromatography coupled to polarity-switching electrospray tandem mass spectrometry.
    Garcia-Ac A; Segura PA; Gagnon C; Sauvé S
    J Environ Monit; 2009 Apr; 11(4):830-8. PubMed ID: 19557238
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of methotrexate in human urine at trace levels by solid phase extraction and high-performance liquid chromatography/tandem mass spectrometry.
    Turci R; Fiorentino ML; Sottani C; Minoia C
    Rapid Commun Mass Spectrom; 2000; 14(3):173-9. PubMed ID: 10637424
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of methotrexate in environmental samples by solid phase extraction and high performance liquid chromatography: ultraviolet or tandem mass spectrometry detection?
    Turci R; Micoli G; Minoia C
    Rapid Commun Mass Spectrom; 2000; 14(8):685-91. PubMed ID: 10786908
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Liquid-liquid extraction procedure for trace determination of cyclophosphamide in human urine by high-performance liquid chromatography tandem mass spectrometry.
    Sottani C; Turci R; Perbellini L; Minoia C
    Rapid Commun Mass Spectrom; 1998; 12(16):1063-8. PubMed ID: 9737012
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous analysis of urinary 4,4'-methylenebis(2-chloroaniline) and N-acetyl 4,4'-methylenebis(2-chloroaniline) using solid-phase extraction and liquid chromatography/tandem mass spectrometry.
    Shih WC; Chen MF; Huang CC; Uang SN; Shih TS; Liou SH; Wu KY
    Rapid Commun Mass Spectrom; 2007; 21(24):4073-8. PubMed ID: 18008389
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multi-residue method for the determination of basic/neutral pharmaceuticals and illicit drugs in surface water by solid-phase extraction and ultra performance liquid chromatography-positive electrospray ionisation tandem mass spectrometry.
    Kasprzyk-Hordern B; Dinsdale RM; Guwy AJ
    J Chromatogr A; 2007 Aug; 1161(1-2):132-45. PubMed ID: 17559858
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automated solid-phase extraction for concentration and clean-up of female steroid hormones prior to liquid chromatography-electrospray ionization-tandem mass spectrometry: an approach to lipidomics.
    Alvarez Sánchez B; Capote FP; Jiménez JR; Luque de Castro MD
    J Chromatogr A; 2008 Oct; 1207(1-2):46-54. PubMed ID: 18790493
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for monitoring methotrexate in the setting of carboxypeptidase-G2 therapy.
    Kumar VS; Law T; Kellogg M
    Methods Mol Biol; 2010; 603():359-63. PubMed ID: 20077087
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The determination of urinary cyclophosphamide at low concentration levels by liquid-liquid extraction and HPLC/MS/MS analysis].
    Sottani C; Turci R; Perbellini L; Minoia C
    G Ital Med Lav Ergon; 1998; 20(4):239-42. PubMed ID: 9987616
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of levetiracetam in human plasma by liquid chromatography/electrospray tandem mass spectrometry and its application to bioequivalence studies.
    Jain DS; Subbaiah G; Sanyal M; Pal U; Shrivastav PS
    Rapid Commun Mass Spectrom; 2006; 20(17):2539-47. PubMed ID: 16878346
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Liquid chromatography/tandem mass spectrometry method for simultaneous determination of risperidone and its active metabolite 9-hydroxyrisperidone in human plasma.
    Bhatt J; Subbaiah G; Singh S
    Rapid Commun Mass Spectrom; 2006; 20(14):2109-14. PubMed ID: 16775814
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction, followed by high-speed liquid chromatography/mass spectrometry, for the determination of a basic drug in human plasma.
    Xue YJ; Akinsanya JB; Liu J; Unger SE
    Rapid Commun Mass Spectrom; 2006; 20(18):2660-8. PubMed ID: 16912986
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.