These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 16717351)

  • 1. Hypercarbia and arrhythmias resulting from faulty Bain circuit: a report of two cases.
    Ghai B; Makkar JK; Bhatia A
    Anesth Analg; 2006 Jun; 102(6):1903-4. PubMed ID: 16717351
    [No Abstract]   [Full Text] [Related]  

  • 2. Another cause of hypercapnia during induction of anesthesia.
    De Armendi AJ; Mayhew JF; Cure JA
    Paediatr Anaesth; 2010 Nov; 20(11):1055. PubMed ID: 20964773
    [No Abstract]   [Full Text] [Related]  

  • 3. Severe hypercarbia with a Bain breathing circuit during malignant hyperthermia reaction.
    Rogers KH; Rose DK; Byrick RJ
    Can J Anaesth; 1987 Nov; 34(6):652-3. PubMed ID: 3677291
    [No Abstract]   [Full Text] [Related]  

  • 4. A faulty Bain circuit.
    Gooch C; Peutrell J
    Anaesthesia; 2004 Jun; 59(6):618. PubMed ID: 15144311
    [No Abstract]   [Full Text] [Related]  

  • 5. Hypercapnia and tachycardia in a 2-year old.
    Karlin A; Umeh U; Girshin M
    Paediatr Anaesth; 2009 Jun; 19(6):629-30. PubMed ID: 19645989
    [No Abstract]   [Full Text] [Related]  

  • 6. Hypercapnia related to a faulty adult co-axial breathing circuit.
    Jellish WS; Nolan T; Kleinman B
    Anesth Analg; 2001 Oct; 93(4):973-4, table of contents. PubMed ID: 11574367
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Partial occlusion of the Bain circuit causes respiratory acidosis under general anesthesia].
    Classen V; Uhrbrand B
    Ugeskr Laeger; 2002 Oct; 164(43):5037-8. PubMed ID: 12422400
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bain circuit adapter fault.
    Allen P
    Anaesth Intensive Care; 2000 Jun; 28(3):333. PubMed ID: 10853223
    [No Abstract]   [Full Text] [Related]  

  • 9. Bain circuit occluded by foreign body.
    Wilkes PR; Lindsay PA
    Can J Anaesth; 1994 Feb; 41(2):137-9. PubMed ID: 8131228
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flaw in a disposable carbon dioxide absorber system.
    Choi JM; Choi IC
    J Anesth; 2014 Dec; 28(6):955. PubMed ID: 24935747
    [No Abstract]   [Full Text] [Related]  

  • 11. [Faulty internal tube in a co-axial ventilation tube system: cause of a massive postoperative hypercapnia].
    Günther JH; Börning P; Bahlmann L
    Anaesthesist; 2013 Mar; 62(3):197-200. PubMed ID: 23475174
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Different scavenging connections on Bain circuits.
    Mayall M; Ahmed RN
    Anaesthesia; 2002 Dec; 57(12):1219-20; author reply 1220. PubMed ID: 12437722
    [No Abstract]   [Full Text] [Related]  

  • 13. Difficulty with leak-testing Bain breathing systems on an Aestiva 5 anaesthetic machine.
    Ip JK; Fauvel NJ
    Anaesthesia; 2008 Mar; 63(3):321-2; discussion 322. PubMed ID: 18289248
    [No Abstract]   [Full Text] [Related]  

  • 14. Faulty Penlon circle absorber.
    Bennett MW; Nowicki RW
    Anaesthesia; 2005 Sep; 60(9):932-3; discussion 933. PubMed ID: 16115260
    [No Abstract]   [Full Text] [Related]  

  • 15. Detection of inner tube defects in co-axial circle and Bain breathing systems: a comparison of occlusion and Pethick tests.
    Szypula KA; Ip JK; Bogod D; Yentis SM
    Anaesthesia; 2008 Oct; 63(10):1092-5. PubMed ID: 18647290
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hypercarbia induced by detachment of inner fresh gas delivery tube of the bain circuit--a case report.
    Jouan ZT; Jawan B; Lee JH
    Acta Anaesthesiol Sin; 1995 Jun; 33(2):129-32. PubMed ID: 7663865
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Severe hypercarbia resulting from inspiratory valve malfunction in two anesthetized horses.
    Baxter GM; Adams JE; Johnson JJ
    J Am Vet Med Assoc; 1991 Jan; 198(1):123-5. PubMed ID: 1995568
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Faulty blease PEEP valve.
    Chandradeva K
    Anaesthesia; 2008 Nov; 63(11):1265-6; discussion 1266. PubMed ID: 19032275
    [No Abstract]   [Full Text] [Related]  

  • 19. Flapper valve malfunction.
    Eisenkraft JB; Sommer RM
    Anesth Analg; 1988 Nov; 67(11):1132. PubMed ID: 3189909
    [No Abstract]   [Full Text] [Related]  

  • 20. Anesthesia case of the month. Severe twist in the inner tube of the coaxial breathing circuit, resulting in obstruction of the inspiratory limb of the circuit.
    Quandt JE
    J Am Vet Med Assoc; 2005 Dec; 227(12):1902-4. PubMed ID: 16379624
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 9.