215 related articles for article (PubMed ID: 16721243)
1. A mechanical evaluation of two fixation methods using cancellous screws for coronal fractures of the lateral condyle of the distal femur (OTA type 33B).
Jarit GJ; Kummer FJ; Gibber MJ; Egol KA
J Orthop Trauma; 2006 Apr; 20(4):273-6. PubMed ID: 16721243
[TBL] [Abstract][Full Text] [Related]
2. Plate fixation for Letenneur type I Hoffa fracture: a biomechanical study.
Sun H; He QF; Huang YG; Pan JF; Luo CF; Chai YM
Injury; 2017 Jul; 48(7):1492-1498. PubMed ID: 28390685
[TBL] [Abstract][Full Text] [Related]
3. A biomechanical comparison of two screw fixation methods in a Letenneur type I Hoffa fracture.
Yao SH; Su WR; Hsu KL; Chen Y; Hong CK; Kuan FC
BMC Musculoskelet Disord; 2020 Jul; 21(1):497. PubMed ID: 32723376
[TBL] [Abstract][Full Text] [Related]
4. Capitellum fractures: a biomechanical evaluation of three fixation methods.
Elkowitz SJ; Polatsch DB; Egol KA; Kummer FJ; Koval KJ
J Orthop Trauma; 2002 Aug; 16(7):503-6. PubMed ID: 12172281
[TBL] [Abstract][Full Text] [Related]
5. [A biomechanical comparison of Acutrak headless compression screw and AO cannulated lag screw for the fixation of Hoffa fracture].
Peng J; Zhang SL; Feng P; Jiang Y; Zou C; Zhang H; Tu CQ
Sichuan Da Xue Xue Bao Yi Xue Ban; 2013 Mar; 44(2):226-30. PubMed ID: 23745261
[TBL] [Abstract][Full Text] [Related]
6. Biomechanics of internal fixation in Hoffa fractures - A comparison of four different constructs.
Pires RE; Rabelo JMG; Cimini CA; Casas EBL; Neder Filho AT; Giordano V; Kfuri M; de Andrade MAP
Injury; 2024 Feb; 55(2):111219. PubMed ID: 38029682
[TBL] [Abstract][Full Text] [Related]
7. Coronal fractures of the distal femoral condyle: a biomechanical evaluation of four internal fixation constructs.
Hak DJ; Nguyen J; Curtiss S; Hazelwood S
Injury; 2005 Sep; 36(9):1103-6. PubMed ID: 15982653
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate.
Higgins TF; Pittman G; Hines J; Bachus KN
J Orthop Trauma; 2007 Jan; 21(1):43-6. PubMed ID: 17211268
[TBL] [Abstract][Full Text] [Related]
9. The effect of locked distal screws in retrograde nailing of osteoporotic distal femur fractures: a laboratory study using cadaver femurs.
Tejwani NC; Park S; Iesaka K; Kummer F
J Orthop Trauma; 2005 Jul; 19(6):380-3. PubMed ID: 16003196
[TBL] [Abstract][Full Text] [Related]
10. Fragment size of lateral Hoffa fractures determines screw fixation trajectory: a human cadaveric cohort study.
Peez C; Zderic I; Deichsel A; Lodde M; Richards RG; Gueorguiev B; Kittl C; Raschke MJ; Herbst E
Acta Orthop; 2024 Jun; 95():290-297. PubMed ID: 38874493
[TBL] [Abstract][Full Text] [Related]
11. Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation.
Knobe M; Nagel P; Maier KJ; Gradl G; Buecking B; Sönmez TT; Modabber A; Prescher A; Pape HC
J Orthop Trauma; 2016 Jan; 30(1):e12-8. PubMed ID: 26849388
[TBL] [Abstract][Full Text] [Related]
12. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.
Grau L; Collon K; Alhandi A; Kaimrajh D; Varon M; Latta L; Vilella F
Surg Technol Int; 2018 Jun; 32():293-297. PubMed ID: 29791694
[TBL] [Abstract][Full Text] [Related]
13. Comparison of 3 Methods for Maintaining Inter-Fragmentary Compression After Fracture Reduction and Fixation.
Au B; Groundland J; Stoops TK; Santoni BG; Sagi HC
J Orthop Trauma; 2017 Apr; 31(4):210-213. PubMed ID: 27984452
[TBL] [Abstract][Full Text] [Related]
14. Buttress Plating Versus Anterior-to-Posterior Lag Screws for Fixation of the Posterior Malleolus: A Biomechanical Study.
Bennett C; Behn A; Daoud A; Nork S; Sangeorzan B; Dikos G; Bishop J
J Orthop Trauma; 2016 Dec; 30(12):664-669. PubMed ID: 27755282
[TBL] [Abstract][Full Text] [Related]
15. Internal fixation of femoral neck fractures with posterior comminution: a biomechanical study.
Kauffman JI; Simon JA; Kummer FJ; Pearlman CJ; Zuckerman JD; Koval KJ
J Orthop Trauma; 1999; 13(3):155-9. PubMed ID: 10206245
[TBL] [Abstract][Full Text] [Related]
16. Comparison of two headless screw designs for fixation of capitellum fractures.
Elkowitz SJ; Kubiak EN; Polatsch D; Cooper J; Kummer FJ; Koval KJ
Bull Hosp Jt Dis; 2003; 61(3-4):123-6. PubMed ID: 15156810
[TBL] [Abstract][Full Text] [Related]
17. The mechanics of internal fixation of fractures of the distal femur: a comparison of the condylar screw (DCS) with the condylar plate (CP).
Harder Y; Martinet O; Barraud GE; Cordey J; Regazzoni P
Injury; 1999; 30 Suppl 1():A31-9. PubMed ID: 10645367
[TBL] [Abstract][Full Text] [Related]
18. Mechanical study of the safe distance between distal femoral fracture site and distal locking screws in antegrade intramedullary nailing.
Antekeier SB; Burden RL; Voor MJ; Roberts CS
J Orthop Trauma; 2005; 19(10):693-7. PubMed ID: 16314716
[TBL] [Abstract][Full Text] [Related]
19. Rotationally stable screw-anchor versus sliding hip screw plate systems in stable trochanteric femur fractures: a biomechanical evaluation.
Knobe M; Gradl G; Maier KJ; Drescher W; Jansen-Troy A; Prescher A; Knechtel T; Antony P; Pape HC
J Orthop Trauma; 2013 Jun; 27(6):e127-36. PubMed ID: 23114419
[TBL] [Abstract][Full Text] [Related]
20. Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone.
Hawks MA; Kim H; Strauss JE; Oliphant BW; Golden RD; Hsieh AH; Nascone JW; O'Toole RV
Clin Biomech (Bristol, Avon); 2013 Oct; 28(8):886-91. PubMed ID: 24050951
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]