These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
310 related articles for article (PubMed ID: 16722488)
1. Corneal and epithelial thickness in keratoconus: a comparison of ultrasonic pachymetry, Orbscan II, and optical coherence tomography. Haque S; Simpson T; Jones L J Refract Surg; 2006 May; 22(5):486-93. PubMed ID: 16722488 [TBL] [Abstract][Full Text] [Related]
3. Central corneal thickness measurements using Orbscan II scanning slit topography, noncontact specular microscopy, and ultrasonic pachymetry in eyes with keratoconus. Kawana K; Miyata K; Tokunaga T; Kiuchi T; Hiraoka T; Oshika T Cornea; 2005 Nov; 24(8):967-71. PubMed ID: 16227843 [TBL] [Abstract][Full Text] [Related]
4. Corneal thickness and elevation measurements using swept-source optical coherence tomography and slit scanning topography in normal and keratoconic eyes. Jhanji V; Yang B; Yu M; Ye C; Leung CK Clin Exp Ophthalmol; 2013 Nov; 41(8):735-45. PubMed ID: 23566209 [TBL] [Abstract][Full Text] [Related]
5. Keratoconus diagnosis with optical coherence tomography pachymetry mapping. Li Y; Meisler DM; Tang M; Lu AT; Thakrar V; Reiser BJ; Huang D Ophthalmology; 2008 Dec; 115(12):2159-66. PubMed ID: 18977536 [TBL] [Abstract][Full Text] [Related]
6. Fourier-domain optical coherence tomography imaging in keratoconus: a corneal structural classification. Sandali O; El Sanharawi M; Temstet C; Hamiche T; Galan A; Ghouali W; Goemaere I; Basli E; Borderie V; Laroche L Ophthalmology; 2013 Dec; 120(12):2403-2412. PubMed ID: 23932599 [TBL] [Abstract][Full Text] [Related]
7. [The study of corneal epithelial change in keratoconic eyes with Fourier-domain optical coherence tomographic pachymetry]. Zhao Y; Hong J; Wang F; Cui X; Yang Y; Zhu X; Wu D; Wei A; Chen Y; Wu S; Huang F; Xu J Zhonghua Yan Ke Za Zhi; 2014 Sep; 50(9):665-70. PubMed ID: 25533557 [TBL] [Abstract][Full Text] [Related]
8. Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus. Temstet C; Sandali O; Bouheraoua N; Hamiche T; Galan A; El Sanharawi M; Basli E; Laroche L; Borderie V J Cataract Refract Surg; 2015 Apr; 41(4):812-20. PubMed ID: 25840306 [TBL] [Abstract][Full Text] [Related]
9. Differentiating Keratoconus and Corneal Warpage by Analyzing Focal Change Patterns in Corneal Topography, Pachymetry, and Epithelial Thickness Maps. Tang M; Li Y; Chamberlain W; Louie DJ; Schallhorn JM; Huang D Invest Ophthalmol Vis Sci; 2016 Jul; 57(9):OCT544-9. PubMed ID: 27482824 [TBL] [Abstract][Full Text] [Related]
10. Thickness mapping of the cornea and epithelium using optical coherence tomography. Haque S; Jones L; Simpson T Optom Vis Sci; 2008 Oct; 85(10):E963-76. PubMed ID: 18832971 [TBL] [Abstract][Full Text] [Related]
11. Agreement among 3 methods to measure corneal thickness: ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography. Li EY; Mohamed S; Leung CK; Rao SK; Cheng AC; Cheung CY; Lam DS Ophthalmology; 2007 Oct; 114(10):1842-7. PubMed ID: 17507097 [TBL] [Abstract][Full Text] [Related]
12. Central and peripheral corneal thickness measurement in normal and keratoconic eyes using three corneal pachymeters. Feizi S; Jafarinasab MR; Karimian F; Hasanpour H; Masudi A J Ophthalmic Vis Res; 2014; 9(3):296-304. PubMed ID: 25667728 [TBL] [Abstract][Full Text] [Related]
13. Corneal pachymetry in normal and keratoconic eyes: Orbscan II versus ultrasound. Gherghel D; Hosking SL; Mantry S; Banerjee S; Naroo SA; Shah S J Cataract Refract Surg; 2004 Jun; 30(6):1272-7. PubMed ID: 15177603 [TBL] [Abstract][Full Text] [Related]
14. Subclinical keratoconus detection by pattern analysis of corneal and epithelial thickness maps with optical coherence tomography. Li Y; Chamberlain W; Tan O; Brass R; Weiss JL; Huang D J Cataract Refract Surg; 2016 Feb; 42(2):284-95. PubMed ID: 27026454 [TBL] [Abstract][Full Text] [Related]
15. Meta-analysis of Pentacam vs. ultrasound pachymetry in central corneal thickness measurement in normal, post-LASIK or PRK, and keratoconic or keratoconus-suspect eyes. Wu W; Wang Y; Xu L Graefes Arch Clin Exp Ophthalmol; 2014 Jan; 252(1):91-9. PubMed ID: 24218039 [TBL] [Abstract][Full Text] [Related]
16. Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post-laser in situ keratomileusis eyes. Prospero Ponce CM; Rocha KM; Smith SD; Krueger RR J Cataract Refract Surg; 2009 Jun; 35(6):1055-62. PubMed ID: 19465292 [TBL] [Abstract][Full Text] [Related]
17. Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes. Li Y; Tan O; Brass R; Weiss JL; Huang D Ophthalmology; 2012 Dec; 119(12):2425-33. PubMed ID: 22917888 [TBL] [Abstract][Full Text] [Related]
18. Repeatability of Epithelium Thickness Measured by an AS-OCT in Different Grades of Keratoconus and Compared to AS-OCT/Placido Topography. Wang Y; Ning R; Li K; Xu H; Li Y; Yang Y; Gustafsson I; Zhou X; Qu X; Huang J Am J Ophthalmol; 2024 Sep; 265():213-223. PubMed ID: 38621521 [TBL] [Abstract][Full Text] [Related]
19. High-speed optical coherence tomography of corneal opacities. Khurana RN; Li Y; Tang M; Lai MM; Huang D Ophthalmology; 2007 Jul; 114(7):1278-85. PubMed ID: 17307254 [TBL] [Abstract][Full Text] [Related]
20. Comparison of corneal thickness measured with optical coherence tomography, ultrasonic pachymetry, and a scanning slit method. Thomas J; Wang J; Rollins AM; Sturm J J Refract Surg; 2006 Sep; 22(7):671-8. PubMed ID: 16995549 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]