These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 16731365)

  • 1. Arterial spin labeling: benefits and pitfalls of high magnetic field.
    Golay X; Petersen ET
    Neuroimaging Clin N Am; 2006 May; 16(2):259-68, x. PubMed ID: 16731365
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pediatric perfusion imaging using pulsed arterial spin labeling.
    Wang J; Licht DJ; Jahng GH; Liu CS; Rubin JT; Haselgrove J; Zimmerman RA; Detre JA
    J Magn Reson Imaging; 2003 Oct; 18(4):404-13. PubMed ID: 14508776
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation study of a pulsed arterial spin labeling technique by comparison to perfusion computed tomography.
    Koziak AM; Winter J; Lee TY; Thompson RT; St Lawrence KS
    Magn Reson Imaging; 2008 May; 26(4):543-53. PubMed ID: 18063336
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of cerebral perfusion with arterial spin labeling: Part 1. Methods.
    Liu TT; Brown GG
    J Int Neuropsychol Soc; 2007 May; 13(3):517-25. PubMed ID: 17445301
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A signal processing model for arterial spin labeling functional MRI.
    Liu TT; Wong EC
    Neuroimage; 2005 Jan; 24(1):207-15. PubMed ID: 15588612
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Arterial spin labeling: validity testing and comparison studies.
    Ewing JR; Cao Y; Knight RA; Fenstermacher JD
    J Magn Reson Imaging; 2005 Dec; 22(6):737-40. PubMed ID: 16261575
    [TBL] [Abstract][Full Text] [Related]  

  • 7. FAIR-TrueFISP imaging of cerebral perfusion in areas of high magnetic susceptibility differences at 1.5 and 3 Tesla.
    Boss A; Martirosian P; Klose U; Nägele T; Claussen CD; Schick F
    J Magn Reson Imaging; 2007 May; 25(5):924-31. PubMed ID: 17410577
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantifying CBF with pulsed ASL: technical and pulse sequence factors.
    Wong EC
    J Magn Reson Imaging; 2005 Dec; 22(6):727-31. PubMed ID: 16261572
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification of rodent cerebral blood flow (CBF) in normal and high flow states using pulsed arterial spin labeling magnetic resonance imaging.
    Wegener S; Wu WC; Perthen JE; Wong EC
    J Magn Reson Imaging; 2007 Oct; 26(4):855-62. PubMed ID: 17896389
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intravascular effect in velocity-selective arterial spin labeling: the choice of inflow time and cutoff velocity.
    Wu WC; Wong EC
    Neuroimage; 2006 Aug; 32(1):122-8. PubMed ID: 16713716
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantification of cerebral perfusion using arterial spin labeling: two-compartment models.
    Parkes LM
    J Magn Reson Imaging; 2005 Dec; 22(6):732-6. PubMed ID: 16267854
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 3.0-T functional brain imaging: a 5-year experience.
    Scarabino T; Giannatempo GM; Popolizio T; Tosetti M; d'Alesio V; Esposito F; Di Salle F; Di Costanzo A; Bertolino A; Maggialetti A; Salvolini U
    Radiol Med; 2007 Feb; 112(1):97-112. PubMed ID: 17310287
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility of velocity selective arterial spin labeling in functional MRI.
    Wu WC; Wong EC
    J Cereb Blood Flow Metab; 2007 Apr; 27(4):831-8. PubMed ID: 16926843
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modeling the effects of flow dispersion in arterial spin labeling.
    Kazan SM; Chappell MA; Payne SJ
    IEEE Trans Biomed Eng; 2009 Jun; 56(6):1635-43. PubMed ID: 19307163
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantification of cerebral blood flow in nonhuman primates using arterial spin labeling and a two-compartment model.
    Zappe AC; Reichold J; Burger C; Weber B; Buck A; Pfeuffer J; Logothetis NK
    Magn Reson Imaging; 2007 Jul; 25(6):775-83. PubMed ID: 17490842
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characterizing the origin of the arterial spin labelling signal in MRI using a multiecho acquisition approach.
    Wells JA; Lythgoe MF; Choy M; Gadian DG; Ordidge RJ; Thomas DL
    J Cereb Blood Flow Metab; 2009 Nov; 29(11):1836-45. PubMed ID: 19654586
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Perfusion magnetic resonance imaging in psychiatry.
    Théberge J
    Top Magn Reson Imaging; 2008 Apr; 19(2):111-30. PubMed ID: 19363433
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla.
    Wang J; Alsop DC; Li L; Listerud J; Gonzalez-At JB; Schnall MD; Detre JA
    Magn Reson Med; 2002 Aug; 48(2):242-54. PubMed ID: 12210932
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging.
    Wong EC; Buxton RB; Frank LR
    Magn Reson Med; 1998 Sep; 40(3):348-55. PubMed ID: 9727936
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements.
    Günther M; Oshio K; Feinberg DA
    Magn Reson Med; 2005 Aug; 54(2):491-8. PubMed ID: 16032686
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.