BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

334 related articles for article (PubMed ID: 16741237)

  • 21. Quantitation of mixed-base populations of HIV-1 variants by automated DNA sequencing with BODIPY dye-labeled primers.
    Metzker ML; Ansari-Lari MA; Liu XM; Holder DJ; Gibbs RA
    Biotechniques; 1998 Sep; 25(3):446-7, 450-2, 454, passim. PubMed ID: 9762443
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Identifying cloned Helicobacter pylori promoters by primer extension using a FAM-labelled primer and GeneScan analysis.
    Lloyd AL; Marshall BJ; Mee BJ
    J Microbiol Methods; 2005 Mar; 60(3):291-8. PubMed ID: 15649531
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Linear amplification sequencing with dye terminators.
    Rosenthal A; Charnock-Jones DS
    Methods Mol Biol; 1993; 23():281-96. PubMed ID: 8220761
    [No Abstract]   [Full Text] [Related]  

  • 24. Modified inter-simple sequence repeat PCR protocol for use in conjunction with the LI-COR Gene ImagIR2 DNA analyzer.
    Jackson JA; Matthews D
    Biotechniques; 2000 May; 28(5):914-6, 918, 920. PubMed ID: 10818697
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Direct PCR sequencing with boronated nucleotides.
    Porter KW; Briley JD; Shaw BR
    Nucleic Acids Res; 1997 Apr; 25(8):1611-7. PubMed ID: 9092670
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Optimization of Applied Biosystems 373 sequencer stretch modification.
    McDonald LA; Kelley JM; Brandon RC; Adams MD
    Biotechniques; 1995 Sep; 19(3):464-71. PubMed ID: 7495561
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Selecting and amplifying one fragment from a DNA fragment mixture by polymerase chain reaction with a pair of selective primers.
    Matsunaga H; Kohara Y; Okano K; Kambara H
    Electrophoresis; 1996 Dec; 17(12):1833-40. PubMed ID: 9034764
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Two-label peak-height encoded DNA sequencing by capillary gel electrophoresis: three examples.
    Chen D; Harke HR; Dovichi NJ
    Nucleic Acids Res; 1992 Sep; 20(18):4873-80. PubMed ID: 1408803
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Internal fluorescence labeling with fluorescent deoxynucleotides in two-label peak-height encoded DNA sequencing by capillary electrophoresis.
    Starke HR; Yan JY; Zhang JZ; Mühlegger K; Effgen K; Dovichi NJ
    Nucleic Acids Res; 1994 Sep; 22(19):3997-4001. PubMed ID: 7937123
    [TBL] [Abstract][Full Text] [Related]  

  • 30. "Doublex" fluorescent DNA sequencing: two independent sequences obtained simultaneously in one reaction with internal labeling and unlabeled primers.
    Wiemann S; Stegemann J; Zimmermann J; Voss H; Benes V; Ansorge W
    Anal Biochem; 1996 Feb; 234(2):166-74. PubMed ID: 8714594
    [TBL] [Abstract][Full Text] [Related]  

  • 31. tDNA-PCR followed by automated fluorescent capillary electrophoresis for identification of bacterial species.
    Baele M; Stakenborg T; Lopes dos Santos Santiago G; Haesebrouck F; Vaneechoutte M
    Cold Spring Harb Protoc; 2009 Apr; 2009(4):pdb.prot5196. PubMed ID: 20147139
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Real-time DNA sequencing from single polymerase molecules.
    Korlach J; Bjornson KP; Chaudhuri BP; Cicero RL; Flusberg BA; Gray JJ; Holden D; Saxena R; Wegener J; Turner SW
    Methods Enzymol; 2010; 472():431-55. PubMed ID: 20580975
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Dideoxy genomic sequencing of a single-copy mammalian gene using more than two hundred cycles of linear amplification.
    Cairns MJ; Murray V
    Biotechniques; 1994 Nov; 17(5):910-4. PubMed ID: 7840972
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Automated differential display using a fluorescently labeled universal primer.
    Smith NR; Aldersley M; Li A; High AS; Moynihan TP; Markham AF; Robinson PA
    Biotechniques; 1997 Aug; 23(2):274-9. PubMed ID: 9266082
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Sequencing reactions for the applied biosystems 373A Automated DNA Sequencer.
    Halloran N; Du Z; Wilson RK
    Methods Mol Biol; 1993; 23():297-315. PubMed ID: 8220762
    [No Abstract]   [Full Text] [Related]  

  • 36. Fluorescent sequencing protocols for the ALF.
    McQuaid S
    Methods Mol Biol; 2001; 167():171-92. PubMed ID: 11265315
    [No Abstract]   [Full Text] [Related]  

  • 37. Automated fluorescent DNA sequencing on the ABI PRISM 377.
    MacBeath JR; Harvey SS; Oldroyd NJ
    Methods Mol Biol; 2001; 167():119-52. PubMed ID: 11265312
    [No Abstract]   [Full Text] [Related]  

  • 38. A multiplexing single nucleotide polymorphism typing method based on restriction-enzyme-mediated single-base extension and capillary electrophoresis.
    Che Y; Chen X
    Anal Biochem; 2004 Jun; 329(2):220-9. PubMed ID: 15158480
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Improvements in Pyrosequencing technology by employing Sequenase polymerase.
    Gharizadeh B; Eriksson J; Nourizad N; Nordström T; Nyrén P
    Anal Biochem; 2004 Jul; 330(2):272-80. PubMed ID: 15203333
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Improved accuracy in direct automated DNA sequencing of small PCR products by optimizing the template concentration.
    Hyder SM; Hu C; Needleman DS; Sonoda Y; Wang XY; Baker VV
    Biotechniques; 1994 Sep; 17(3):478-82. PubMed ID: 7818900
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.