319 related articles for article (PubMed ID: 16751132)
21. The Importance of Nucleated Red Blood Cells in Patients with Beta Thalassemia Major and Comparison of Two Automated Systems with Manual Microscopy and Flow Cytometry.
Karakukcu M; Karakukcu C; Unal E; Ozturk A; Ciraci Z; Patiroglu T; Ozdemir MA
Clin Lab; 2015; 61(9):1289-95. PubMed ID: 26554249
[TBL] [Abstract][Full Text] [Related]
22. Do placental sections accurately reflect umbilical cord nucleated red blood cell and white blood cell differential counts?
Bryant C; Beall M; McPhaul L; Fortson W; Ross M
J Matern Fetal Neonatal Med; 2006 Feb; 19(2):105-8. PubMed ID: 16581606
[TBL] [Abstract][Full Text] [Related]
23. Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS.
Thalhammer-Scherrer R; Knöbl P; Korninger L; Schwarzinger I
Arch Pathol Lab Med; 1997 Jun; 121(6):573-7. PubMed ID: 9199621
[TBL] [Abstract][Full Text] [Related]
24. Umbilical cord nucleated red blood cell counts: normal values and the effect of labor.
McCarthy JM; Capullari T; Thompson Z; Zhu Y; Spellacy WN
J Perinatol; 2006 Feb; 26(2):89-92. PubMed ID: 16407961
[TBL] [Abstract][Full Text] [Related]
25. Are elevated fetal nucleated red blood cell counts an indirect reflection of enhanced erythropoietin activity?
Ferber A; Fridel Z; Weissmann-Brenner A; Minior VK; Divon MY
Am J Obstet Gynecol; 2004 May; 190(5):1473-5. PubMed ID: 15167873
[TBL] [Abstract][Full Text] [Related]
26. Evaluation of the coulter LH 750 haematology analyzer compared with flow cytometry as the reference method for WBC, platelet and nucleated RBC count.
Igout J; Fretigny M; Vasse M; Callat MP; Silva M; Willemont L; Gelle M; Lenormand B
Clin Lab Haematol; 2004 Feb; 26(1):1-7. PubMed ID: 14738430
[TBL] [Abstract][Full Text] [Related]
27. An evaluation of the performance of Sysmex XE-2100 in enumerating nucleated red cells in peripheral blood.
Gulati G; Behling E; Kocher W; Schwarting R
Arch Pathol Lab Med; 2007 Jul; 131(7):1077-83. PubMed ID: 17616994
[TBL] [Abstract][Full Text] [Related]
28. [Automated hematology analysers and spurious counts Part 3. Haemoglobin, red blood cells, cell count and indices, reticulocytes].
Godon A; Genevieve F; Marteau-Tessier A; Zandecki M
Ann Biol Clin (Paris); 2012; 70(2):155-68. PubMed ID: 22484526
[TBL] [Abstract][Full Text] [Related]
29. [Evaluation of the blood analyzer Beckman Coulter LH 750: analytic performance, decision rules].
Amouroux I; Balay M; Marfaing-Koka A
Ann Biol Clin (Paris); 2003; 61(5):576-84. PubMed ID: 14671756
[TBL] [Abstract][Full Text] [Related]
30. Reference ranges for blood concentrations of nucleated red blood cells in neonates.
Christensen RD; Henry E; Andres RL; Bennett ST
Neonatology; 2011; 99(4):289-94. PubMed ID: 21135564
[TBL] [Abstract][Full Text] [Related]
31. An evaluation of the utility of performing body fluid counts on the coulter LH 750.
Barnes PW; Eby CS; Shimer G
Lab Hematol; 2004; 10(3):127-31. PubMed ID: 15479646
[TBL] [Abstract][Full Text] [Related]
32. Automated counting of nucleated red blood cells in blood samples of newborns.
de Keijzer MH; van der Meer W
Clin Lab Haematol; 2002 Dec; 24(6):343-5. PubMed ID: 12452814
[TBL] [Abstract][Full Text] [Related]
33. Comparative evaluation of schistocyte counting by an automated method and by microscopic determination.
Lesesve JF; Salignac S; Alla F; Defente M; Benbih M; Bordigoni P; Lecompte T
Am J Clin Pathol; 2004 May; 121(5):739-45. PubMed ID: 15151214
[TBL] [Abstract][Full Text] [Related]
34. Stability of hematological analytes depends on the hematology analyser used: a stability study with Bayer Advia 120, Beckman Coulter LH 750 and Sysmex XE 2100.
Imeri F; Herklotz R; Risch L; Arbetsleitner C; Zerlauth M; Risch GM; Huber AR
Clin Chim Acta; 2008 Nov; 397(1-2):68-71. PubMed ID: 18706900
[TBL] [Abstract][Full Text] [Related]
35. Are placental chorionic capillary nucleated red blood cell counts useful compared to umbilical cord blood tests?
McCarthy JM; Gilbert-Barness E; Tsibris JC; Spellacy WN
Fetal Diagn Ther; 2007; 22(2):121-3. PubMed ID: 17135757
[TBL] [Abstract][Full Text] [Related]
36. Effects of yeast on automated cell counting.
Branda JA; Kratz A
Am J Clin Pathol; 2006 Aug; 126(2):248-54. PubMed ID: 16891201
[TBL] [Abstract][Full Text] [Related]
37. Comparison of five automated hematology analyzers in a university hospital setting: Abbott Cell-Dyn Sapphire, Beckman Coulter DxH 800, Siemens Advia 2120i, Sysmex XE-5000, and Sysmex XN-2000.
Bruegel M; Nagel D; Funk M; Fuhrmann P; Zander J; Teupser D
Clin Chem Lab Med; 2015 Jun; 53(7):1057-71. PubMed ID: 25720071
[TBL] [Abstract][Full Text] [Related]
38. Performance evaluation of the PENTRA 60C+ automated hematology analyzer and comparison with the ADVIA 2120.
Guerti K; Vertessen F; Daniëls L; Van Der Planken M
Int J Lab Hematol; 2009 Apr; 31(2):132-41. PubMed ID: 19267810
[TBL] [Abstract][Full Text] [Related]
39. Validation of body fluid analysis on the Coulter LH 750.
Brown W; Keeney M; Chin-Yee I; Johnson K; Lantis K; Finn W; Wolfe N; Kaplan S
Lab Hematol; 2003; 9(3):155-9. PubMed ID: 14521323
[TBL] [Abstract][Full Text] [Related]
40. The correlation between automated hematology and manually read smears for the determination of nucleated red blood cells in umbilical cord blood.
McCarthy JM; Capullari T; Spellacy WN
J Matern Fetal Neonatal Med; 2005 Mar; 17(3):199-201. PubMed ID: 16147823
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]