These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 16752572)

  • 1. Fast voxel and polygon ray-tracing algorithms in intensity modulated radiation therapy treatment planning.
    Fox C; Romeijn HE; Dempsey JF
    Med Phys; 2006 May; 33(5):1364-71. PubMed ID: 16752572
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A finite size pencil beam for IMRT dose optimization.
    Jeleń U; Söhn M; Alber M
    Phys Med Biol; 2005 Apr; 50(8):1747-66. PubMed ID: 15815094
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of beam intensity in a single step for IMRT inverse planning.
    Chuang KS; Chen TJ; Kuo SC; Jan ML; Hwang IM; Chen S; Lin YC; Wu J
    Phys Med Biol; 2003 Feb; 48(3):293-306. PubMed ID: 12608608
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code.
    Francescon P; Cora S; Chiovati P
    Med Phys; 2003 Feb; 30(2):144-57. PubMed ID: 12607832
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations.
    Vanderstraeten B; Reynaert N; Paelinck L; Madani I; De Wagter C; De Gersem W; De Neve W; Thierens H
    Med Phys; 2006 Sep; 33(9):3149-58. PubMed ID: 17022207
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Investigation of geometrical and scoring grid resolution for Monte Carlo dose calculations for IMRT.
    De Smedt B; Vanderstraeten B; Reynaert N; De Neve W; Thierens H
    Phys Med Biol; 2005 Sep; 50(17):4005-19. PubMed ID: 16177526
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of beamlet step-size on IMRT plan quality.
    Zhang G; Jiang Z; Shepard D; Earl M; Yu C
    Med Phys; 2005 Nov; 32(11):3448-54. PubMed ID: 16370431
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT.
    Yang Y; Xing L; Li JG; Palta J; Chen Y; Luxton G; Boyer A
    Med Phys; 2003 Nov; 30(11):2937-47. PubMed ID: 14655941
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An optimization algorithm for intensity modulated radiotherapy--the simulated dynamics with dose-volume constraints.
    Hou Q; Wang J; Chen Y; Galvin JM
    Med Phys; 2003 Jan; 30(1):61-8. PubMed ID: 12557980
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A technique for generating phase-space-based Monte Carlo beamlets in radiotherapy applications.
    Bush K; Popescu IA; Zavgorodni S
    Phys Med Biol; 2008 Sep; 53(18):N337-47. PubMed ID: 18711246
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A particle swarm optimization algorithm for beam angle selection in intensity-modulated radiotherapy planning.
    Li Y; Yao D; Yao J; Chen W
    Phys Med Biol; 2005 Aug; 50(15):3491-514. PubMed ID: 16030379
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Beamlet dose distribution compression and reconstruction using wavelets for intensity modulated treatment planning.
    Zakarian C; Deasy JO
    Med Phys; 2004 Feb; 31(2):368-75. PubMed ID: 15000623
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reduction of IMRT beam complexity through the use of beam modulation penalties in the objective function.
    Matuszak MM; Larsen EW; Fraass BA
    Med Phys; 2007 Feb; 34(2):507-20. PubMed ID: 17388168
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A nonvoxel-based dose convolution/superposition algorithm optimized for scalable GPU architectures.
    Neylon J; Sheng K; Yu V; Chen Q; Low DA; Kupelian P; Santhanam A
    Med Phys; 2014 Oct; 41(10):101711. PubMed ID: 25281950
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Adaptive beamlet-based finite-size pencil beam dose calculation for independent verification of IMRT and VMAT.
    Park JC; Li JG; Arhjoul L; Yan G; Lu B; Fan Q; Liu C
    Med Phys; 2015 Apr; 42(4):1836-50. PubMed ID: 25832074
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels.
    Lu W; Olivera GH; Chen ML; Reckwerdt PJ; Mackie TR
    Phys Med Biol; 2005 Feb; 50(4):655-80. PubMed ID: 15773626
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Three-dimensional portal image-based dose reconstruction in a virtual phantom for rapid evaluation of IMRT plans.
    Ansbacher W
    Med Phys; 2006 Sep; 33(9):3369-82. PubMed ID: 17022233
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A topographic leaf-sequencing algorithm for delivering intensity modulated radiation therapy.
    Desai D; Ramsey CR; Breinig M; Mahan SL
    Med Phys; 2006 Aug; 33(8):2751-6. PubMed ID: 16964850
    [TBL] [Abstract][Full Text] [Related]  

  • 19. IMRT dose shaping with regionally variable penalty scheme.
    Cotrutz C; Xing L
    Med Phys; 2003 Apr; 30(4):544-51. PubMed ID: 12722806
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets.
    Capote R; Sánchez-Doblado F; Leal A; Lagares JI; Arráns R; Hartmann GH
    Med Phys; 2004 Sep; 31(9):2416-22. PubMed ID: 15487721
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.