These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

223 related articles for article (PubMed ID: 16754194)

  • 1. Can pacemakers, neurostimulators, leads, or guide wires be MRI safe? Technological concerns and possible resolutions.
    Helfer JL; Gray RW; MacDonald SG; Bibens TW
    Minim Invasive Ther Allied Technol; 2006; 15(2):114-20. PubMed ID: 16754194
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients: a prospective study with 115 examinations.
    Sommer T; Naehle CP; Yang A; Zeijlemaker V; Hackenbroch M; Schmiedel A; Meyer C; Strach K; Skowasch D; Vahlhaus C; Litt H; Schild H
    Circulation; 2006 Sep; 114(12):1285-92. PubMed ID: 16966587
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cardiac pacemaker: in vitro assessment at 1.5 T.
    Shellock FG; Fieno DS; Thomson LJ; Talavage TM; Berman DS
    Am Heart J; 2006 Feb; 151(2):436-43. PubMed ID: 16442911
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cardiac pacemakers and implantable cardioverter defibrillators: in vitro magnetic resonance imaging evaluation at 1.5-tesla.
    Shellock FG; Fischer L; Fieno DS
    J Cardiovasc Magn Reson; 2007; 9(1):21-31. PubMed ID: 17178677
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Magnetic resonance imaging for patients with permanent pacemakers: initial clinical experience.
    Goldsher D; Amikam S; Boulos M; Suleiman M; Shreiber R; Eran A; Goldshmid Y; Mazbar R; Roguin A
    Isr Med Assoc J; 2006 Feb; 8(2):91-4. PubMed ID: 16544729
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vivo heating of pacemaker leads during magnetic resonance imaging.
    Luechinger R; Zeijlemaker VA; Pedersen EM; Mortensen P; Falk E; Duru F; Candinas R; Boesiger P
    Eur Heart J; 2005 Feb; 26(4):376-83; discussion 325-7. PubMed ID: 15618060
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pacemaker lead tip heating in abandoned and pacemaker-attached leads at 1.5 Tesla MRI.
    Langman DA; Goldberg IB; Finn JP; Ennis DB
    J Magn Reson Imaging; 2011 Feb; 33(2):426-31. PubMed ID: 21274985
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Safety and imaging quality of MRI in pediatric and adult congenital heart disease patients with pacemakers.
    Pulver AF; Puchalski MD; Bradley DJ; Minich LL; Su JT; Saarel EV; Whitaker P; Etheridge SP
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):450-6. PubMed ID: 19335853
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro investigation of pacemaker lead heating induced by magnetic resonance imaging: role of implant geometry.
    Calcagnini G; Triventi M; Censi F; Mattei E; Bartolini P; Kainz W; Bassen HI
    J Magn Reson Imaging; 2008 Oct; 28(4):879-86. PubMed ID: 18821629
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Numerical model for estimating RF-induced heating on a pacemaker implant during MRI: experimental validation.
    Mattei E; Calcagnini G; Censi F; Triventi M; Bartolini P
    IEEE Trans Biomed Eng; 2010 Aug; 57(8):2045-52. PubMed ID: 20176532
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Pacemaker or ICD and MRI: is MRI safety the new standard?].
    Amara W
    Ann Cardiol Angeiol (Paris); 2011 Nov; 60(5):279-81. PubMed ID: 21907320
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Magnetic resonance imaging compatibility and safety of the SOUNDTEC Direct System.
    Dyer RK; Nakmali D; Dormer KJ
    Laryngoscope; 2006 Aug; 116(8):1321-33. PubMed ID: 16885731
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Safety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.
    Baikoussis NG; Apostolakis E; Papakonstantinou NA; Sarantitis I; Dougenis D
    Ann Thorac Surg; 2011 Jun; 91(6):2006-11. PubMed ID: 21531377
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Safety of MRI at 1.5Tesla in patients with implanted sacral nerve neurostimulator.
    Elkelini MS; Hassouna MM
    Eur Urol; 2006 Aug; 50(2):311-6. PubMed ID: 16530923
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Implantable medical devices MRI safe.
    Dal Molin R; Hecker B
    Stud Health Technol Inform; 2013; 189():96-100. PubMed ID: 23739365
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MRI in patients with cardiac implantable electronic devices.
    Cronin EM; Mahon N; Wilkoff BL
    Expert Rev Med Devices; 2012 Mar; 9(2):139-46. PubMed ID: 22404775
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calculation of MRI-induced heating of an implanted medical lead wire with an electric field transfer function.
    Park SM; Kamondetdacha R; Nyenhuis JA
    J Magn Reson Imaging; 2007 Nov; 26(5):1278-85. PubMed ID: 17969143
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simple design changes to wires to substantially reduce MRI-induced heating at 1.5 T: implications for implanted leads.
    Gray RW; Bibens WT; Shellock FG
    Magn Reson Imaging; 2005 Oct; 23(8):887-91. PubMed ID: 16275428
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Safety of MRI in patients with implanted deep brain stimulation devices.
    Tagliati M; Jankovic J; Pagan F; Susatia F; Isaias IU; Okun MS;
    Neuroimage; 2009 Aug; 47 Suppl 2():T53-7. PubMed ID: 19376247
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Not all pacemakers are created equal: MRI conditional pacemaker and lead technology.
    Ahmed FZ; Morris GM; Allen S; Khattar R; Mamas M; Zaidi A
    J Cardiovasc Electrophysiol; 2013 Sep; 24(9):1059-65. PubMed ID: 24016320
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.