These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

342 related articles for article (PubMed ID: 16760710)

  • 21. Time-dependent analysis of leaflets in mechanical aortic bileaflet heart valves in closing phase using the finite strip method.
    Mohammadi H; Ahmadian MT; Wan WK
    Med Eng Phys; 2006 Mar; 28(2):122-33. PubMed ID: 15946890
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A coupled fluid-structure finite element model of the aortic valve and root.
    Nicosia MA; Cochran RP; Einstein DR; Rutland CJ; Kunzelman KS
    J Heart Valve Dis; 2003 Nov; 12(6):781-9. PubMed ID: 14658821
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Predicting ATS Open Pivot heart valve performance with computational fluid dynamics.
    Dumont K; Vierendeels JA; Segers P; Van Nooten GJ; Verdonck PR
    J Heart Valve Dis; 2005 May; 14(3):393-9. PubMed ID: 15974535
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.
    Dumont K; Vierendeels J; Kaminsky R; van Nooten G; Verdonck P; Bluestein D
    J Biomech Eng; 2007 Aug; 129(4):558-65. PubMed ID: 17655477
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity.
    Lee H; Homma A; Taenaka Y
    Artif Organs; 2007 Jul; 31(7):532-7. PubMed ID: 17584477
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The effect of tip angle on cavitation potential during closure of a bileaflet prosthesis model.
    Zhang P; Yeo JH; Qian P; Hwang NH
    J Heart Valve Dis; 2007 Jul; 16(4):430-9. PubMed ID: 17702370
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Passive flow control of bileaflet mechanical heart valve leakage flow.
    Dasi LP; Murphy DW; Glezer A; Yoganathan AP
    J Biomech; 2008; 41(6):1166-73. PubMed ID: 18374925
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Direct imaging of bileaflet mechanical valve behavior in the tricuspid position.
    Ikeda K; Okazaki Y; Furukawa K; Ohtsubo S; Yunoki J; Natsuaki M; Itoh T
    Eur J Cardiothorac Surg; 2006 Jun; 29(6):1014-9. PubMed ID: 16675254
    [TBL] [Abstract][Full Text] [Related]  

  • 29. High-resolution assessment of velocity fields and shear stresses distal to prosthetic heart valves using high-field magnetic resonance imaging.
    Ringgaard S; Botnar RM; Djurhuus C; Stodkilde-Jorgensen H; Hasenkam JM; Boesiger P; Pedersen EM
    J Heart Valve Dis; 1999 Jan; 8(1):96-103. PubMed ID: 10096490
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A detailed fluid mechanics study of tilting disk mechanical heart valve closure and the implications to blood damage.
    Manning KB; Herbertson LH; Fontaine AA; Deutsch S
    J Biomech Eng; 2008 Aug; 130(4):041001. PubMed ID: 18601443
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Fluid dynamic assessment of three polymeric heart valves using particle image velocimetry.
    Leo HL; Dasi LP; Carberry J; Simon HA; Yoganathan AP
    Ann Biomed Eng; 2006 Jun; 34(6):936-52. PubMed ID: 16783650
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [The numerical simulation of pulsatile flow in a tapered blood vessel].
    Qiu L; Fan Y; Dong B; Yuan Z
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Aug; 21(4):558-61. PubMed ID: 15357431
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Dependence of tissue valve leaflet motion on the viscosity of blood analogue fluid.
    Chandran KB; Fatemi R; Schoephoerster R
    Life Support Syst; 1986; 4(4):289-303. PubMed ID: 3561030
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Hemodynamics of the mitral valve under edge-to-edge repair: an in vitro steady flow study.
    Shi L; He Z
    J Biomech Eng; 2009 May; 131(5):051010. PubMed ID: 19388780
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Principal stress analysis in LDA measurement of the flow field downstream of 19-mm Sorin Bicarbon heart valve.
    Barbaro V; Grigioni M; Daniele C; D'Avenio G
    Technol Health Care; 1998 Nov; 6(4):259-70. PubMed ID: 9924953
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effects of dynamic saddle annulus and leaflet length on transmitral flow pattern and leaflet stress of a bileaflet bioprosthetic mitral valve.
    Kheradvar A; Falahatpisheh A
    J Heart Valve Dis; 2012 Mar; 21(2):225-33. PubMed ID: 22645859
    [TBL] [Abstract][Full Text] [Related]  

  • 37. In vitro fluid dynamic characteristics of aortic bioprostheses: old versus new.
    Woo YR; Sung HW; Williams FP; Yoganathan AP
    Life Support Syst; 1986; 4(1):63-85. PubMed ID: 2937982
    [TBL] [Abstract][Full Text] [Related]  

  • 38. New insights into the assessment of the prosthetic valve performance in the presence of subaortic stenosis through a fluid-structure interaction model.
    Guivier C; Deplano V; Pibarot P
    J Biomech; 2007; 40(10):2283-90. PubMed ID: 17161842
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The 12 cc Penn State pulsatile pediatric ventricular assist device: fluid dynamics associated with valve selection.
    Cooper BT; Roszelle BN; Long TC; Deutsch S; Manning KB
    J Biomech Eng; 2008 Aug; 130(4):041019. PubMed ID: 18601461
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An integrated macro/micro approach to evaluating pivot flow within the Medtronic ADVANTAGE bileaflet mechanical heart valve.
    Shu MC; Gross JM; O'Rourke KK; Yoganathan AP
    J Heart Valve Dis; 2003 Jul; 12(4):503-12. PubMed ID: 12918854
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.