These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 16767456)

  • 1. [Chronic cobalt poisoning in endoprosthetic replacement].
    Steens W; Loehr JF; von Foerster G; Katzer A
    Orthopade; 2006 Aug; 35(8):860-4. PubMed ID: 16767456
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Systemic toxicity related to metal hip prostheses.
    Bradberry SM; Wilkinson JM; Ferner RE
    Clin Toxicol (Phila); 2014; 52(8):837-47. PubMed ID: 25132471
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fatal cobalt toxicity after total hip arthroplasty revision for fractured ceramic components.
    Fox KA; Phillips TM; Yanta JH; Abesamis MG
    Clin Toxicol (Phila); 2016 Nov; 54(9):874-877. PubMed ID: 27491800
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty.
    Oldenburg M; Wegner R; Baur X
    J Arthroplasty; 2009 Aug; 24(5):825.e15-20. PubMed ID: 18835128
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Severe cobalt poisoning with loss of sight after ceramic-metal pairing in a hip--a case report.
    Steens W; von Foerster G; Katzer A
    Acta Orthop; 2006 Oct; 77(5):830-2. PubMed ID: 17068719
    [No Abstract]   [Full Text] [Related]  

  • 6. Severe metallosis leading to femoral head perforation.
    Sharma OP; Lochab J; Berkovich Y; Safir OA; Gross AE
    Orthopedics; 2013 Feb; 36(2):e241-3. PubMed ID: 23383625
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner.
    Zywiel MG; Brandt JM; Overgaard CB; Cheung AC; Turgeon TR; Syed KA
    Bone Joint J; 2013 Jan; 95-B(1):31-7. PubMed ID: 23307670
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Severe cobalt intoxication following hip replacement revision: clinical features and outcome.
    Pelclova D; Sklensky M; Janicek P; Lach K
    Clin Toxicol (Phila); 2012 Apr; 50(4):262-5. PubMed ID: 22455358
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cobalt toxicity after revision total hip replacement due to fracture of a ceramic head.
    Pelayo-de Tomás JM; Novoa-Parra C; Gómez-Barbero P
    Rev Esp Cir Ortop Traumatol; 2017; 61(3):203-207. PubMed ID: 28131541
    [TBL] [Abstract][Full Text] [Related]  

  • 10. ["Why am I Deaf and my Vision is Blurred?" Thinking of a Horse or a Zebra?].
    Dolliana P; Nüesch R
    Praxis (Bern 1994); 2016 Mar; 105(5):279-81. PubMed ID: 26934012
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Massive metallosis after revision of a fractured ceramic head onto a metal head.
    Matziolis G; Perka C; Disch A
    Arch Orthop Trauma Surg; 2003 Feb; 123(1):48-50. PubMed ID: 12582797
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Are Females at Greater Risk for Revision Surgery After Hip Resurfacing Arthroplasty With the Articular Surface Replacement Prosthesis?
    Donahue GS; Lindgren V; Galea VP; Madanat R; Muratoglu O; Malchau H
    Clin Orthop Relat Res; 2016 Oct; 474(10):2257-65. PubMed ID: 27121872
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Abrasive wear and metallosis associated with cross-linked polyethylene in total hip arthroplasty.
    O'Brien ST; Burnell CD; Hedden DR; Brandt JM
    J Arthroplasty; 2013 Jan; 28(1):197.e17-21. PubMed ID: 22770854
    [TBL] [Abstract][Full Text] [Related]  

  • 14. First case report of vanadium metallosis after ceramic-on-ceramic total hip arthroplasty.
    Pesce V; Maccagnano G; Vicenti G; Notarnicola A; Lovreglio P; Soleo L; Pantalone A; Salini V; Moretti B
    J Biol Regul Homeost Agents; 2013; 27(4):1063-8. PubMed ID: 24382188
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Revision total hip arthroplasty due to pain from hypersensitivity to cobalt-chromium in total hip arthroplasty.
    Kosukegawa I; Nagoya S; Kaya M; Sasaki K; Sasaki M; Yamashita T
    J Arthroplasty; 2011 Sep; 26(6):978.e1-3. PubMed ID: 21130600
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hard-on-Hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty.
    Nam D; Barrack T; Johnson SR; Nunley RM; Barrack RL
    Clin Orthop Relat Res; 2016 Oct; 474(10):2115-22. PubMed ID: 26911973
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture--a case report.
    Hasegawa M; Sudo A; Uchida A
    Acta Orthop; 2006 Oct; 77(5):833-5. PubMed ID: 17068720
    [No Abstract]   [Full Text] [Related]  

  • 19. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty.
    Witzleb WC; Ziegler J; Krummenauer F; Neumeister V; Guenther KP
    Acta Orthop; 2006 Oct; 77(5):697-705. PubMed ID: 17068698
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Serum-cobalt levels with metal-on-metal bearings in the cement-free total hip arthroplasty results covering two years; prospective study.
    Weissinger M; Grübl A; Pöll G
    Acta Chir Orthop Traumatol Cech; 2011; 78(5):410-5. PubMed ID: 22094154
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.