  • 21. On two versions of a 3-pi algorithm for spiral CT.
    Katsevich A
    Phys Med Biol; 2004 Jun; 49(11):2129-43. PubMed ID: 15248568
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A backprojection-filtration algorithm for nonstandard spiral cone-beam CT with an n-PI-window.
    Yu H; Ye Y; Zhao S; Wang G
    Phys Med Biol; 2005 May; 50(9):2099-111. PubMed ID: 15843739
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Impact of polychromatic x-ray sources on helical, cone-beam computed tomography and dual-energy methods.
    Sidky EY; Zou Y; Pan X
    Phys Med Biol; 2004 Jun; 49(11):2293-303. PubMed ID: 15248578
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A new weighting scheme for cone-beam helical CT to reduce the image noise.
    Taguchi K; Chiang BS; Silver MD
    Phys Med Biol; 2004 Jun; 49(11):2351-64. PubMed ID: 15248582
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Redundant data and exact helical cone-beam reconstruction.
    Heuscher D; Brown K; Noo F
    Phys Med Biol; 2004 Jun; 49(11):2219-38. PubMed ID: 15248574
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Region-of-interest reconstruction of motion-contaminated data using a weighted backprojection filtration algorithm.
    King M; Pan X; Yu L; Giger M
    Med Phys; 2006 May; 33(5):1222-38. PubMed ID: 16752557
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Image reconstruction in peripheral and central regions-of-interest and data redundancy.
    Pan X; Zou Y; Xia D
    Med Phys; 2005 Mar; 32(3):673-84. PubMed ID: 15839339
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of z-axis resolution and image noise for nonconstant velocity spiral CT data reconstructed using a weighted 3D filtered backprojection (WFBP) reconstruction algorithm.
    Christner JA; Stierstorfer K; Primak AN; Eusemann CD; Flohr TG; McCollough CH
    Med Phys; 2010 Feb; 37(2):897-906. PubMed ID: 20229899
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Tilted cone-beam reconstruction with row-wise fan-to-parallel rebinning.
    Hsieh J; Tang X
    Phys Med Biol; 2006 Oct; 51(20):5259-76. PubMed ID: 17019037
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Handling of long objects in iterative improvement of nonexact reconstruction in helical cone-beam CT.
    Magnusson M; Danielsson PE; SunnegÄrdh J
    IEEE Trans Med Imaging; 2006 Jul; 25(7):935-40. PubMed ID: 16827493
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT.
    Zbijewski W; Beekman FJ
    IEEE Trans Med Imaging; 2006 Jul; 25(7):817-27. PubMed ID: 16827483
    [TBL] [Abstract][Full Text] [Related]  

  • 32. PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch.
    Zou Y; Pan X; Xia D; Wang G
    Med Phys; 2005 Aug; 32(8):2639-48. PubMed ID: 16193794
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.
    Tang X; Hsieh J; Nilsen RA; Dutta S; Samsonov D; Hagiwara A
    Phys Med Biol; 2006 Feb; 51(4):855-74. PubMed ID: 16467583
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A new scheme for view-dependent data differentiation in fan-beam and cone-beam computed tomography.
    Noo F; Hoppe S; Dennerlein F; Lauritsch G; Hornegger J
    Phys Med Biol; 2007 Sep; 52(17):5393-414. PubMed ID: 17762094
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Penalized-likelihood reconstruction for metal artifact reduction in cone-beam CT.
    Aootaphao S; Pintavirooj C; Sotthivirat S
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():2733-6. PubMed ID: 19163270
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Fully truncated cone-beam reconstruction on Pi lines using prior CT.
    Ramamurthi K; Strobel N; Fahrig R; Prince JL
    Med Image Comput Comput Assist Interv; 2005; 8(Pt 1):631-8. PubMed ID: 16685899
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A local region of interest image reconstruction via filtered backprojection for fan-beam differential phase-contrast computed tomography.
    Qi Z; Chen GH
    Phys Med Biol; 2007 Sep; 52(18):N417-23. PubMed ID: 17804875
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Reduction of artifacts induced by misaligned geometry in cone-beam CT.
    Sun Y; Hou Y; Hu J
    IEEE Trans Biomed Eng; 2007 Aug; 54(8):1461-71. PubMed ID: 17694867
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Streaking artifacts reduction in four-dimensional cone-beam computed tomography.
    Leng S; Zambelli J; Tolakanahalli R; Nett B; Munro P; Star-Lack J; Paliwal B; Chen GH
    Med Phys; 2008 Oct; 35(10):4649-59. PubMed ID: 18975711
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Cone-beam reconstruction using the backprojection of locally filtered projections.
    Pack JD; Noo F; Clackdoyle R
    IEEE Trans Med Imaging; 2005 Jan; 24(1):70-85. PubMed ID: 15638187
    [TBL] [Abstract][Full Text] [Related]  