155 related articles for article (PubMed ID: 16772687)
1. Bis(2-hydroxyacetophenone)ethylenediimine as a neutral carrier in a coated-wire membrane electrode for lead(II).
Mazloum Ardakani M; Pourhakak P; Salavati-Niasari M
Anal Sci; 2006 Jun; 22(6):865-70. PubMed ID: 16772687
[TBL] [Abstract][Full Text] [Related]
2. A copper ion-selective electrode with high selectivity prepared by sol-gel and coated wire techniques.
Mazloum Ardakani M; Salavati-Niasari M; Khayat Kashani M; Ghoreishi SM
Anal Bioanal Chem; 2004 Mar; 378(6):1659-65. PubMed ID: 15214432
[TBL] [Abstract][Full Text] [Related]
3. Coated wire silver-ion selective electrode based on a N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene.
Zare HR; Salavati-Niassary M; Memarzadeh F; Mazloum M; Nasirizadeh N
Anal Sci; 2004 May; 20(5):815-9. PubMed ID: 15171286
[TBL] [Abstract][Full Text] [Related]
4. Coated-wire copper(II)-selective electrode based on phenylglyoxal-alpha-monoxime ionophore.
Firooz AR; Mazloum M; Safari J; Amini MK
Anal Bioanal Chem; 2002 Mar; 372(5-6):718-22. PubMed ID: 11941444
[TBL] [Abstract][Full Text] [Related]
5. Silver(I)-selective coated-wire electrode based on an octahydroxycalix[4]arene derivative.
Ardakani MM; Ensafi AA; Salavati Niasari M; Mirhoseini H
Anal Sci; 2003 Aug; 19(8):1187-90. PubMed ID: 12945675
[TBL] [Abstract][Full Text] [Related]
6. Potentiometric determination of silver(I) by selective membrane electrode based on derivative of porphyrin.
Mazloum Ardakani M; Dehghani H; Jalayer M; Zare HR
Anal Sci; 2004 Dec; 20(12):1667-72. PubMed ID: 15636513
[TBL] [Abstract][Full Text] [Related]
7. Highly selective and sensitive copper membrane electrode based on a new synthesized Schiff base.
Gholivand MB; Rahimi-Nasrabadi M; Ganjali MR; Salavati-Niasari M
Talanta; 2007 Sep; 73(3):553-60. PubMed ID: 19073070
[TBL] [Abstract][Full Text] [Related]
8. Novel potentiometric sensor for monitoring beryllium based on naphto-9-crown-3.
Ganjali MR; Daftari A; Faal-Rastegar M; Moghimi A
Anal Sci; 2003 Mar; 19(3):353-6. PubMed ID: 12675338
[TBL] [Abstract][Full Text] [Related]
9. Nickel(II) selective membrane potentiometric sensor using a recently synthesized mercapto compound as neutral carrier.
Mashhadizadeh MH; Momeni A
Talanta; 2003 Jan; 59(1):47-53. PubMed ID: 18968883
[TBL] [Abstract][Full Text] [Related]
10. Mercury(II) ion-selective electrodes based on p-tert-butyl calix[4]crowns with imine units.
Mahajan RK; Kaur R; Kaur I; Sharma V; Kumar M
Anal Sci; 2004 May; 20(5):811-4. PubMed ID: 15171285
[TBL] [Abstract][Full Text] [Related]
11. Silver(I) ion-selective membrane based on Schiff base-p-tert-butylcalix[4]arene.
Mahajan RK; Kumar M; Sharma V; Kaur I
Analyst; 2001 Apr; 126(4):505-7. PubMed ID: 11340988
[TBL] [Abstract][Full Text] [Related]
12. Lead(II)-selective electrode based on phenyl disulfide.
Abbaspour A; Khajeh B
Anal Sci; 2002 Sep; 18(9):987-91. PubMed ID: 12243415
[TBL] [Abstract][Full Text] [Related]
13. Mercury(II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base.
Mashhadizadeh MH; Sheikhshoaie I
Talanta; 2003 May; 60(1):73-80. PubMed ID: 18969027
[TBL] [Abstract][Full Text] [Related]
14. A mercury(II) ion-selective electrode based on neutral salicylaldehyde thiosemicarbazone.
Mahajan RK; Kaur I; Lobana TS
Talanta; 2003 Jan; 59(1):101-5. PubMed ID: 18968889
[TBL] [Abstract][Full Text] [Related]
15. Cadmium ion-selective electrode based on tetrathia-12-crown-4.
Shamsipur M; Mashhadizadeh MH
Talanta; 2001 Jan; 53(5):1065-71. PubMed ID: 18968198
[TBL] [Abstract][Full Text] [Related]
16. A mercury(II) selective sensor based on N,N'-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples.
Abu-Shawish HM
J Hazard Mater; 2009 Aug; 167(1-3):602-8. PubMed ID: 19195781
[TBL] [Abstract][Full Text] [Related]
17. A coated wire-type lead(II) ion-selective electrode based on a phosphorylated calix[4]arene derivative.
Yaftian MR; Rayati S; Emadi D; Matt D
Anal Sci; 2006 Aug; 22(8):1075-8. PubMed ID: 16896245
[TBL] [Abstract][Full Text] [Related]
18. Nickel analysis in real samples by Ni2+ selective PVC membrane electrode based on a new Schiff base.
Tomar PK; Chandra S; Malik A; Kumar A
Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):4978-84. PubMed ID: 24094213
[TBL] [Abstract][Full Text] [Related]
19. Strontium(II)-selective electrode based on a macrocyclic tetraamide.
Singh AK; Saxena P; Mehtab S; Gupta B
Talanta; 2006 Apr; 69(2):521-6. PubMed ID: 18970598
[TBL] [Abstract][Full Text] [Related]
20. Synthesis of a new oxime and its application to the construction of a highly selective and sensitive Co(II) PVC-based membrane sensor.
Ganjali MR; Mizani F; Emami M; Darjezini M; Darvich MR; Yousefi M
Anal Sci; 2004 Mar; 20(3):531-5. PubMed ID: 15068300
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]