These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

306 related articles for article (PubMed ID: 16779621)

  • 1. The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform.
    Shelley KH; Awad AA; Stout RG; Silverman DG
    J Clin Monit Comput; 2006 Apr; 20(2):81-7. PubMed ID: 16779621
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ventilation-Induced Modulation of Pulse Oximeter Waveforms: A Method for the Assessment of Early Changes in Intravascular Volume During Spinal Fusion Surgery in Pediatric Patients.
    Alian AA; Atteya G; Gaal D; Golembeski T; Smith BG; Dai F; Silverman DG; Shelley K
    Anesth Analg; 2016 Aug; 123(2):346-56. PubMed ID: 27284998
    [TBL] [Abstract][Full Text] [Related]  

  • 3. What is the best site for measuring the effect of ventilation on the pulse oximeter waveform?
    Shelley KH; Jablonka DH; Awad AA; Stout RG; Rezkanna H; Silverman DG
    Anesth Analg; 2006 Aug; 103(2):372-7, table of contents. PubMed ID: 16861419
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multicenter Study Validating Accuracy of a Continuous Respiratory Rate Measurement Derived From Pulse Oximetry: A Comparison With Capnography.
    Bergese SD; Mestek ML; Kelley SD; McIntyre R; Uribe AA; Sethi R; Watson JN; Addison PS
    Anesth Analg; 2017 Apr; 124(4):1153-1159. PubMed ID: 28099286
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A computer algorithm for differentiating valid from distorted pulse oximeter waveforms in neonates.
    Adams JA; Inman IM; Abreu SA; Zabaleta IA; Sackner MA
    Pediatr Pulmonol; 1995 May; 19(5):307-11. PubMed ID: 7567206
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Robust peak detection of pulse waveform using height ratio.
    Xu L; Meng MQ; Liu R; Wang K
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():3856-9. PubMed ID: 19163554
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Extracting respiratory data from pulse oximeter plethysmogram traces in newborn infants.
    Wertheim D; Olden C; Savage E; Seddon P
    Arch Dis Child Fetal Neonatal Ed; 2009 Jul; 94(4):F301-3. PubMed ID: 19015221
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Advanced Uses of Pulse Oximetry for Monitoring Mechanically Ventilated Patients.
    Tusman G; Bohm SH; Suarez-Sipmann F
    Anesth Analg; 2017 Jan; 124(1):62-71. PubMed ID: 27183375
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detection of movement artifact in recorded pulse oximeter saturation.
    Poets CF; Stebbens VA
    Eur J Pediatr; 1997 Oct; 156(10):808-11. PubMed ID: 9365075
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated Pulse Oximeter Waveform Analysis to Track Changes in Blood Pressure During Anesthesia Induction: A Proof-of-Concept Study.
    Ghamri Y; Proença M; Hofmann G; Renevey P; Bonnier G; Braun F; Axis A; Lemay M; Schoettker P
    Anesth Analg; 2020 May; 130(5):1222-1233. PubMed ID: 32287129
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry.
    Ramsay MA; Usman M; Lagow E; Mendoza M; Untalan E; De Vol E
    Anesth Analg; 2013 Jul; 117(1):69-75. PubMed ID: 23632055
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Arterial-pulse oximetry loops: a new method of monitoring vascular tone.
    Shelley KH; Murray WB; Chang D
    J Clin Monit; 1997 Jul; 13(4):223-8. PubMed ID: 9269615
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Estimation of airway obstruction using oximeter plethysmograph waveform data.
    Arnold DH; Spiro DM; Desmond RA; Hagood JS
    Respir Res; 2005 Jun; 6(1):65. PubMed ID: 15985171
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Respiratory physiology and the impact of different modes of ventilation on the photoplethysmographic waveform.
    Alian AA; Shelley KH
    Sensors (Basel); 2012; 12(2):2236-54. PubMed ID: 22438762
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Development of a method of continuous monitoring of spontaneous respiration in the postoperative phase. 1. Normal values for cutaneous pO2- and pCO2-partial pressure together with pulse oximetry determined oxygen saturation in healthy young volunteers].
    Lehmann KA; Asoklis S; Grond S; Huttarsch H
    Anaesthesist; 1992 Mar; 41(3):121-9. PubMed ID: 1570883
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pulse oximetry-derived respiratory rate in general care floor patients.
    Addison PS; Watson JN; Mestek ML; Ochs JP; Uribe AA; Bergese SD
    J Clin Monit Comput; 2015 Feb; 29(1):113-20. PubMed ID: 24796734
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure during major abdominal surgery.
    Hengy B; Gazon M; Schmitt Z; Benyoub K; Bonnet A; Viale JP; Aubrun F
    Anesthesiology; 2012 Nov; 117(5):973-80. PubMed ID: 23042225
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An algorithm for the detection of individual breaths from the pulse oximeter waveform.
    Leonard P; Grubb NR; Addison PS; Clifton D; Watson JN
    J Clin Monit Comput; 2004 Dec; 18(5-6):309-12. PubMed ID: 15957620
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel approach to monitor nonstationary dynamics in physiological signals: application to blood pressure, pulse oximeter, and respiratory data.
    Yang B; Chon KH
    Ann Biomed Eng; 2010 Nov; 38(11):3478-88. PubMed ID: 20544285
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.