These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 16781424)

  • 1. Computer-assisted surgery: a wine before its time: in the affirmative.
    Callaghan JJ; Liu SS; Warth LC
    J Arthroplasty; 2006 Jun; 21(4 Suppl 1):27-8. PubMed ID: 16781424
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Computer-assisted total-knee arthroplasty. Comparison of two successive systems. Learning curve].
    Bové JC
    Rev Chir Orthop Reparatrice Appar Mot; 2008 May; 94(3):252-60. PubMed ID: 18456060
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative study between computer assisted-navigation and conventional technique in minimally invasive surgery total knee arthroplasty, prospective control study.
    Chotanaphuti T; Ongnamthip P; Teeraleekul K; Kraturerk C
    J Med Assoc Thai; 2008 Sep; 91(9):1382-8. PubMed ID: 18843868
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computer-assisted surgery: a wine before its time: in opposition.
    Stulberg BN; Zadzilka JD
    J Arthroplasty; 2006 Jun; 21(4 Suppl 1):29-32. PubMed ID: 16781425
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Computer-assisted surgery in total knee replacement. Preliminary results: report of 60 cases].
    El Masri F; Rammal H; Ghanem I; El Hage S; El Abiad R; Kharrat K; Dagher F
    Rev Chir Orthop Reparatrice Appar Mot; 2008 May; 94(3):261-7. PubMed ID: 18456061
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Rotational alignment of femoral component with computed-assisted surgery (CAS) during total knee arthroplasty].
    Michaut M; Beaufils P; Galaud B; Abadie P; Boisrenoult P; Fallet L
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Oct; 94(6):580-4. PubMed ID: 18929753
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Computer-assisted navigation increases precision of component placement in total knee arthroplasty.
    Pandher DS; Oh KJ; Boaparai RS; Josan GS
    Clin Orthop Relat Res; 2007 Jan; 454():281-2. PubMed ID: 17065843
    [No Abstract]   [Full Text] [Related]  

  • 8. An overview of economic issues in computer-assisted total joint arthroplasty.
    Beringer DC; Patel JJ; Bozic KJ
    Clin Orthop Relat Res; 2007 Oct; 463():26-30. PubMed ID: 17960672
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Minimally invasive computer-assisted total knee arthroplasty through a subvastus approach.
    Zanasi S
    Orthopedics; 2006 Oct; 29(10 Suppl):S142-4. PubMed ID: 17407942
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Experimental research for position accuracy of caput femoris center in total knee replacement navigation surgery].
    Zhang J; Nie W; Wang C; Yang Q
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Dec; 25(6):1435-7. PubMed ID: 19166225
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Experience with computer-assisted navigation for total knee arthroplasty in a community setting.
    Carter RE; Rush PF; Smid JA; Smith WL
    J Arthroplasty; 2008 Aug; 23(5):707-13. PubMed ID: 18534523
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Computer-assisted dynamic total knee arthroplasty using Whiteside's line for alignment.
    Picard F; Gregori A; Dean F; Mennessier A; Dillon J
    Orthopedics; 2006 Oct; 29(10 Suppl):S104-7. PubMed ID: 17407932
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The accuracy of bone resections made during computer navigated total knee replacement. Do we resect what the computer plans we resect?
    Biant LC; Yeoh K; Walker PM; Bruce WJ; Walsh WR
    Knee; 2008 Jun; 15(3):238-41. PubMed ID: 18358725
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Navigated shorter incision or smaller implant in knee arthritis?
    Confalonieri N; Manzotti A; Pullen C
    Clin Orthop Relat Res; 2007 Oct; 463():63-7. PubMed ID: 17589366
    [TBL] [Abstract][Full Text] [Related]  

  • 15. When computer-assisted knee replacement is the best alternative.
    Fehring TK; Mason JB; Moskal J; Pollock DC; Mann J; Williams VJ
    Clin Orthop Relat Res; 2006 Nov; 452():132-6. PubMed ID: 16906112
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimally invasive computer-navigated total knee arthroplasty.
    Biasca N; Schneider TO; Bungartz M
    Orthop Clin North Am; 2009 Oct; 40(4):537-63, x. PubMed ID: 19773060
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The current status of computer-assisted high tibial osteotomy, unicompartmental knee replacement, and revision total knee replacement.
    Jenny JY
    Instr Course Lect; 2008; 57():721-6. PubMed ID: 18399619
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Bone morphing system for rotational alignment in total knee arthroplasty].
    Wu H; van Driessche S; Goutallier D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Jan; 22(1):12-5. PubMed ID: 18361228
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The reliability of navigation-guided gap technique in total knee arthroplasty.
    Han SB; Nha KW; Yoon JR; Lee DH; Chae IJ
    Orthopedics; 2008 Oct; 31(10 Suppl 1):. PubMed ID: 19298036
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Computer-assisted total knee arthroplasty: 12 years experience in Grenoble].
    Saragaglia D
    Bull Acad Natl Med; 2009 Jan; 193(1):91-104; discussion 104-5. PubMed ID: 19718983
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.