BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 16785244)

  • 1. Phenomenological study of the ionisation density-dependence of TLD-100 peak 5a.
    Brandan ME; Angeles O; Mercado-Uribe H
    Radiat Prot Dosimetry; 2006; 119(1-4):29-32. PubMed ID: 16785244
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Track structure approach to the calculation of peak 5a to peak 5 (TLD-100) relative intensities following heavy charged particle irradiation.
    Horowitz YS; Satinger D; Avila O
    Radiat Prot Dosimetry; 2006; 119(1-4):45-8. PubMed ID: 16644996
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of ionisation density on the glow curve structure of LiF:Mg,Ti (TLD-100): the behaviour of composite glow peak 5 in 'slow-cooled' material.
    Fuks E; Horowitz Y; Oster L; Belaish Y; Shahar BB
    Radiat Prot Dosimetry; 2007; 126(1-4):194-7. PubMed ID: 17562651
    [TBL] [Abstract][Full Text] [Related]  

  • 4. LET and dose dependence of TLD-100 glow curve after exposure to intermediate-energy ions.
    Massillon-Jl G; Gamboa-deBuen I; Brandan ME
    Radiat Prot Dosimetry; 2006; 120(1-4):341-4. PubMed ID: 16565204
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The electron energy dependence of the TL response for CVD diamonds.
    Wrobel F; Serrano B; Benabdesselam M; Iacconi P; Costa A
    Radiat Prot Dosimetry; 2006; 119(1-4):49-52. PubMed ID: 16735567
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Response of LiF:Mg,Ti to low energy carbon and oxygen ions.
    Rodríguez-Villafuerte M; Avila O; Buenfil AE; Gamboa-deBuen I; Ruiz CG; Brandan ME
    Radiat Prot Dosimetry; 2006; 119(1-4):106-10. PubMed ID: 16698969
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental investigation of the 100 keV X-ray dose response of the high-temperature thermoluminescence in LiF:Mg,Ti (TLD-100): theoretical interpretation using the unified interaction model.
    Livingstone J; Horowitz YS; Oster L; Datz H; Lerch M; Rosenfeld A; Horowitz A
    Radiat Prot Dosimetry; 2010 Mar; 138(4):320-33. PubMed ID: 19934115
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of absorbed dose and deep traps on thermoluminescence response: a numerical simulation.
    Mady F; Bindi R; Iacconi P; Wrobel F
    Radiat Prot Dosimetry; 2006; 119(1-4):37-40. PubMed ID: 16644969
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A study on the behaviour of TLD-100 glow peaks at extreme ambient temperatures in Riyadh, Saudi Arabia.
    Al-Haj AN; Lagarde CS
    Radiat Prot Dosimetry; 2006; 119(1-4):430-3. PubMed ID: 16735566
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Glow peak temperature, supralinearity and LET dependence of TLDs--correlation studies.
    Pradhan AS; Bakshi AK
    Radiat Prot Dosimetry; 2006; 119(1-4):276-9. PubMed ID: 16644991
    [TBL] [Abstract][Full Text] [Related]  

  • 11. On the relationship between dose-, energy- and LET-response of thermoluminescent detectors.
    Olko P; Bilski P; El-Faramawy NA; Göksu HY; Kim JL; Kopec R; Waligórski MP
    Radiat Prot Dosimetry; 2006; 119(1-4):15-22. PubMed ID: 16644968
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Study of the glow curves of TLD exposed to thermal neutrons.
    Triolo A; Brai M; Marrale M; Gennaro G; Bartolotta A
    Radiat Prot Dosimetry; 2007; 126(1-4):333-6. PubMed ID: 17502321
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Kerma rate effects on thermoluminescent response of CVD diamond.
    Wrobel F; Benabdesselam M; Iacconi P; Mady F
    Radiat Prot Dosimetry; 2006; 119(1-4):115-8. PubMed ID: 16581925
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mysteries of LiF TLD response following high ionisation density irradiation: nanodosimetry and track structure theory, dose response and glow curve shapes.
    Horowitz Y; Fuks E; Datz H; Oster L; Livingstone J; Rosenfeld A
    Radiat Prot Dosimetry; 2011 Jun; 145(4):356-72. PubMed ID: 21106636
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Advanced multistage deconvolution applied to composite glow peak 5 in LiF:Mg,Ti (TLD-100).
    Horowitz YS; Fuks E; Oster L; Podpalov L; Belaish Y; Shachar BB
    Radiat Prot Dosimetry; 2007; 126(1-4):322-5. PubMed ID: 17517677
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ionisation density dependence of the optically and thermally stimulated luminescence from Al2O3:C.
    Yukihara EG; McKeever SW
    Radiat Prot Dosimetry; 2006; 119(1-4):206-17. PubMed ID: 16585262
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calculation and properties of trap structural functions for various spatially correlated systems.
    Mandowski A
    Radiat Prot Dosimetry; 2006; 119(1-4):85-8. PubMed ID: 16702242
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of spectrally resolved thermoluminescence of LiF:Mg,Cu,P detectors by the surface fitting method using algorithm for unrestricted peak positions.
    Mandowska E; Mandowski A; Bilski P; Swiatek J
    Radiat Prot Dosimetry; 2006; 119(1-4):89-92. PubMed ID: 16614088
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pre- and post-irradiation fading of 6LiF:Mg,Ti (TLD-600) exposed to thermal neutrons.
    Vainblat N; German U; Weinstein M; Alfassi ZB
    Radiat Prot Dosimetry; 2007; 126(1-4):318-21. PubMed ID: 17496295
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Defect centres and thermoluminescence in CaSO4:Dy,Ag phosphor.
    Bhatt BC; Dhabekar B; Kumar R; Rao TK; Lakshmanan AR
    Radiat Prot Dosimetry; 2006; 119(1-4):53-6. PubMed ID: 16709708
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.