These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 1678758)

  • 1. Re-use of enteral feeding tubes--a potential hazard to the patient? A study of the efficiency of a representative range of cleaning and disinfection procedures.
    Anderton A; Nwoguh CE
    J Hosp Infect; 1991 Jun; 18(2):131-8. PubMed ID: 1678758
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microbiological evaluation of four enteral feeding systems which have been deliberately subjected to faulty handling procedures.
    Beattie TK; Anderton A
    J Hosp Infect; 1999 May; 42(1):11-20. PubMed ID: 10363206
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of microbial contamination of enteral feeding solution between repeated use of administration sets after washing with water and after washing followed by disinfection.
    Oie S; Kamiya A
    J Hosp Infect; 2001 Aug; 48(4):304-7. PubMed ID: 11461132
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microbial contamination of enteral feeding solution and its prevention.
    Oie S; Kamiya A; Hironaga K; Koshiro A
    Am J Infect Control; 1993 Feb; 21(1):34-8. PubMed ID: 8442520
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microbial contamination of enteral feeding solution and its prevention.
    Oie S; Kamiya A; Hironaga K; Koshiro A
    Am J Infect Control; 1992 Aug; 20(4):202-5. PubMed ID: 1524268
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microbial contamination of suction tubes attached to suction instruments and preventive methods.
    Yorioka K; Oie S; Kamiya A
    Jpn J Infect Dis; 2010 Mar; 63(2):124-7. PubMed ID: 20332576
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigations of the effectiveness of detergent washing, drying and chemical disinfection on contamination of cleaning cloths.
    Scott E; Bloomfield SF
    J Appl Bacteriol; 1990 Mar; 68(3):279-83. PubMed ID: 2341327
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neonatal enteral feeding tubes as loci for colonisation by members of the Enterobacteriaceae.
    Hurrell E; Kucerova E; Loughlin M; Caubilla-Barron J; Hilton A; Armstrong R; Smith C; Grant J; Shoo S; Forsythe S
    BMC Infect Dis; 2009 Sep; 9():146. PubMed ID: 19723318
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analysis of sites of bacterial contamination in an enteral feeding system.
    Mathus-Vliegen EM; Bredius MW; Binnekade JM
    JPEN J Parenter Enteral Nutr; 2006; 30(6):519-25. PubMed ID: 17047178
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microbial contamination of enteral feeding tubes occurring during nutritional treatment.
    Bussy V; Marechal F; Nasca S
    JPEN J Parenter Enteral Nutr; 1992; 16(6):552-7. PubMed ID: 1494212
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Contamination of gastrostomy feeding systems in children in a home-based enteral nutrition program.
    Bott L; Husson MO; Guimber D; Michaud L; Arnaud-Battandier F; Turck D; Gottrand F
    J Pediatr Gastroenterol Nutr; 2001 Sep; 33(3):266-70. PubMed ID: 11593120
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of poor handling procedures on enteral feeding systems in Hong Kong.
    Lee CH; Hodgkiss IJ
    J Hosp Infect; 1999 Jun; 42(2):119-23. PubMed ID: 10389061
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Natural bioburden levels detected on rigid lumened medical devices before and after cleaning.
    Chan-Myers H; McAlister D; Antonoplos P
    Am J Infect Control; 1997 Dec; 25(6):471-6. PubMed ID: 9437486
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A laboratory-based evaluation of tube blocking and microbial risks associated with one blended enteral feed recipe.
    Madden AM; Baines S; Bothwell S; Chen E; Goh S; Jerome L; Sommariva-Nagle C; Szychta M
    J Hum Nutr Diet; 2019 Oct; 32(5):667-675. PubMed ID: 31270891
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of handling procedures on microbial contamination of enteral feeds.
    Anderton A; Aidoo KE
    J Hosp Infect; 1988 May; 11(4):364-72. PubMed ID: 2899589
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of two whole-room ultraviolet irradiation systems for enhanced disinfection of contaminated hospital patient rooms.
    Ali S; Yui S; Muzslay M; Wilson APR
    J Hosp Infect; 2017 Oct; 97(2):180-184. PubMed ID: 28823547
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biofilm growth on the Lopez enteral feeding valve cultured in enteral nutrition: potential implications for medical-surgical patients, nursing care, and research.
    Solseng T; Vinson H; Gibbs P; Greenwald B
    Medsurg Nurs; 2009; 18(4):225-7, 233. PubMed ID: 20552848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effect of handling procedures on microbial contamination of enteral feeds--a comparison of the use of sterile vs non-sterile gloves.
    Anderton A; Aidoo KE
    J Hosp Infect; 1991 Apr; 17(4):297-301. PubMed ID: 1677655
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microbial contamination of enteral feed administration sets in a pediatric institution.
    Matlow A; Wray R; Goldman C; Streitenberger L; Freeman R; Kovach D
    Am J Infect Control; 2003 Feb; 31(1):49-53. PubMed ID: 12548258
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of the risk of contamination of enteral nutrition bottles based on the simulation of home use conditions and hygiene procedures.
    da Silva ITF; Medeiros CO; Leobet J; Beux MR; Rabito EI; Etgeton SAP; Fiori LS
    Nutr Clin Pract; 2024 Aug; 39(4):873-880. PubMed ID: 38491970
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.