290 related articles for article (PubMed ID: 16792298)
1. Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study.
Sanchez JC; Alba N; Nishida T; Batich C; Carney PR
IEEE Trans Neural Syst Rehabil Eng; 2006 Jun; 14(2):217-21. PubMed ID: 16792298
[TBL] [Abstract][Full Text] [Related]
2. Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex.
Suner S; Fellows MR; Vargas-Irwin C; Nakata GK; Donoghue JP
IEEE Trans Neural Syst Rehabil Eng; 2005 Dec; 13(4):524-41. PubMed ID: 16425835
[TBL] [Abstract][Full Text] [Related]
3. In-vivo implant mechanics of flexible, silicon-based ACREO microelectrode arrays in rat cerebral cortex.
Jensen W; Yoshida K; Hofmann UG
IEEE Trans Biomed Eng; 2006 May; 53(5):934-40. PubMed ID: 16686416
[TBL] [Abstract][Full Text] [Related]
4. Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex.
Kipke DR; Vetter RJ; Williams JC; Hetke JF
IEEE Trans Neural Syst Rehabil Eng; 2003 Jun; 11(2):151-5. PubMed ID: 12899260
[TBL] [Abstract][Full Text] [Related]
5. Voltage pulses change neural interface properties and improve unit recordings with chronically implanted microelectrodes.
Otto KJ; Johnson MD; Kipke DR
IEEE Trans Biomed Eng; 2006 Feb; 53(2):333-40. PubMed ID: 16485763
[TBL] [Abstract][Full Text] [Related]
6. Nanostructured surface modification of ceramic-based microelectrodes to enhance biocompatibility for a direct brain-machine interface.
Moxon KA; Kalkhoran NM; Markert M; Sambito MA; McKenzie JL; Webster JT
IEEE Trans Biomed Eng; 2004 Jun; 51(6):881-9. PubMed ID: 15188854
[TBL] [Abstract][Full Text] [Related]
7. Ceramic-based multisite electrode arrays for chronic single-neuron recording.
Moxon KA; Leiser SC; Gerhardt GA; Barbee KA; Chapin JK
IEEE Trans Biomed Eng; 2004 Apr; 51(4):647-56. PubMed ID: 15072219
[TBL] [Abstract][Full Text] [Related]
8. Cortical recording with polypyrrole microwire electrodes.
Bae WJ; Ruddy BP; Richardson AG; Hunter IW; Bizzi E
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5794-7. PubMed ID: 19164034
[TBL] [Abstract][Full Text] [Related]
9. A MEMS-based flexible multichannel ECoG-electrode array.
Rubehn B; Bosman C; Oostenveld R; Fries P; Stieglitz T
J Neural Eng; 2009 Jun; 6(3):036003. PubMed ID: 19436080
[TBL] [Abstract][Full Text] [Related]
10. Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants.
Prasad A; Xue QS; Sankar V; Nishida T; Shaw G; Streit WJ; Sanchez JC
J Neural Eng; 2012 Oct; 9(5):056015. PubMed ID: 23010756
[TBL] [Abstract][Full Text] [Related]
11. A MEMS fabricated flexible electrode array for recording surface field potentials.
Hollenberg BA; Richards CD; Richards R; Bahr DF; Rector DM
J Neurosci Methods; 2006 May; 153(1):147-53. PubMed ID: 16352343
[TBL] [Abstract][Full Text] [Related]
12. An acute method for multielectrode recording from the interior of sulci and other deep brain areas.
Purushothaman G; Scott BB; Bradley DC
J Neurosci Methods; 2006 May; 153(1):86-94. PubMed ID: 16316688
[TBL] [Abstract][Full Text] [Related]
13. A fully integrated mixed-signal neural processor for implantable multichannel cortical recording.
Sodagar AM; Wise KD; Najafi K
IEEE Trans Biomed Eng; 2007 Jun; 54(6 Pt 1):1075-88. PubMed ID: 17554826
[TBL] [Abstract][Full Text] [Related]
14. Compact movable microwire array for long-term chronic unit recording in cerebral cortex of primates.
Jackson A; Fetz EE
J Neurophysiol; 2007 Nov; 98(5):3109-18. PubMed ID: 17855584
[TBL] [Abstract][Full Text] [Related]
15. HermesB: a continuous neural recording system for freely behaving primates.
Santhanam G; Linderman MD; Gilja V; Afshar A; Ryu SI; Meng TH; Shenoy KV
IEEE Trans Biomed Eng; 2007 Nov; 54(11):2037-50. PubMed ID: 18018699
[TBL] [Abstract][Full Text] [Related]
16. Design and fabrication of a polyimide-based microelectrode array: application in neural recording and repeatable electrolytic lesion in rat brain.
Chen YY; Lai HY; Lin SH; Cho CW; Chao WH; Liao CH; Tsang S; Chen YF; Lin SY
J Neurosci Methods; 2009 Aug; 182(1):6-16. PubMed ID: 19467262
[TBL] [Abstract][Full Text] [Related]
17. Microtube-based electrode arrays for low invasive extracellular recording with a high signal-to-noise ratio.
Takei K; Kawano T; Kawashima T; Sawada K; Kaneko H; Ishida M
Biomed Microdevices; 2010 Feb; 12(1):41-8. PubMed ID: 19757069
[TBL] [Abstract][Full Text] [Related]
18. A cortical recording platform utilizing microECoG electrode arrays.
Kim J; Wilson JA; Williams JC
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5353-7. PubMed ID: 18003217
[TBL] [Abstract][Full Text] [Related]
19. Electrophysiological mapping of cat primary auditory cortex with multielectrode arrays.
Kim SJ; Manyam SC; Warren DJ; Normann RA
Ann Biomed Eng; 2006 Feb; 34(2):300-9. PubMed ID: 16496084
[TBL] [Abstract][Full Text] [Related]
20. Application of floating silicon-based linear multielectrode arrays for acute recording of single neuron activity in awake behaving monkeys.
Bonini L; Maranesi M; Livi A; Bruni S; Fogassi L; Holzhammer T; Paul O; Ruther P
Biomed Tech (Berl); 2014 Aug; 59(4):273-81. PubMed ID: 24434299
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]