These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
579 related articles for article (PubMed ID: 16796834)
1. [Visualization of intimal proliferation of drug-eluting stent and bare mental stent by use of optical coherence tomography]. Chen BX; Ma FY; Luo W; Xie WL; Sun SH; Guo XM; Wang F; Zhao XZ; Chu XW Zhonghua Yi Xue Za Zhi; 2006 Apr; 86(16):1102-6. PubMed ID: 16796834 [TBL] [Abstract][Full Text] [Related]
2. Neointimal coverage on drug-eluting stent struts crossing side-branch vessels using optical coherence tomography. Her AY; Lee BK; Shim JM; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Hong MK Am J Cardiol; 2010 Jun; 105(11):1565-9. PubMed ID: 20494663 [TBL] [Abstract][Full Text] [Related]
3. A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS Trial): rationale, design and methods. Poerner TC; Otto S; Gassdorf J; Janiak F; Danzer C; Ferrari M; Figulla HR EuroIntervention; 2011 May; 7 Suppl K():K93-9. PubMed ID: 22027737 [TBL] [Abstract][Full Text] [Related]
4. A single center investigation of bare-metal or drug-eluting stent restenosis from 1633 consecutive Chinese Han ethnic patients. Xu B; Li JJ; Yang YJ; Ma WH; Chen JL; Qiao SB; Qin XW; Yao M; Liu HB; Wu YJ; Yuan JQ; Chen J; You SJ; Dai J; Xia R; Gao RL Chin Med J (Engl); 2006 Apr; 119(7):533-8. PubMed ID: 16620692 [TBL] [Abstract][Full Text] [Related]
5. Neointimal coverage of sirolimus-eluting stents 6 months and 12 months after implantation: evaluation by optical coherence tomography. Yao ZH; Matsubara T; Inada T; Suzuki Y; Suzuki T Chin Med J (Engl); 2008 Mar; 121(6):503-7. PubMed ID: 18364133 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of neointimal coverage of overlapping sirolimus-eluting stents by optical coherence tomography. Tian F; Chen YD; Sun ZJ; Chen L; Yuan F; Song XT; Lü SZ Chin Med J (Engl); 2009 Mar; 122(6):670-4. PubMed ID: 19323932 [TBL] [Abstract][Full Text] [Related]
7. Intimal hyperplasia by optical coherence tomography after BMS and DES implantation in the same artery. Karantalis V; Davlouros P; Alexopoulos D Int J Cardiol; 2011 May; 148(3):e66-7. PubMed ID: 19329194 [TBL] [Abstract][Full Text] [Related]
8. Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: an optical coherence tomography study. Davlouros PA; Nikokiris G; Karantalis V; Mavronasiou E; Xanthopoulou I; Damelou A; Tsigkas G; Alexopoulos D Int J Cardiol; 2011 Sep; 151(2):155-9. PubMed ID: 20605242 [TBL] [Abstract][Full Text] [Related]
9. Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Takano M; Inami S; Jang IK; Yamamoto M; Murakami D; Seimiya K; Ohba T; Mizuno K Am J Cardiol; 2007 Apr; 99(8):1033-8. PubMed ID: 17437723 [TBL] [Abstract][Full Text] [Related]
10. Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial. Kim JS; Jang IK; Fan C; Kim TH; Kim JS; Park SM; Choi EY; Lee SH; Ko YG; Choi D; Hong MK; Jang Y JACC Cardiovasc Interv; 2009 Dec; 2(12):1240-7. PubMed ID: 20129551 [TBL] [Abstract][Full Text] [Related]
11. Long-term clinical outcomes after sirolimus-eluting stent implantation for treatment of restenosis within bare-metal versus drug-eluting stents. Whan Lee C; Kim SH; Suh J; Park DW; Lee SH; Kim YH; Hong MK; Kim JJ; Park SW; Park SJ Catheter Cardiovasc Interv; 2008 Apr; 71(5):594-8. PubMed ID: 18311841 [TBL] [Abstract][Full Text] [Related]
12. Comparison of drug eluting stents with bare metal stents in daily practice for bifurcation lesions in Chinese patients. Kang S; Yang YJ; Xu B; Chen JL; Qiao SB; Yao M; Chen J; Wu YJ; Liu HB; Dai J; Yuan JQ; Li JJ; Gao RL Chin Med J (Engl); 2006 Jul; 119(14):1157-64. PubMed ID: 16863606 [TBL] [Abstract][Full Text] [Related]
13. Preliminary observations using optical coherence tomography to assess neointimal coverage of a metal stent in a porcine model. Mills JS; N'diaye CS; Yow E; Urtz M; Povsic TJ; Greenfield JC; Phillips HR Cardiovasc Revasc Med; 2009; 10(4):229-35. PubMed ID: 19815170 [TBL] [Abstract][Full Text] [Related]
14. Relationship between neointimal coverage of sirolimus-eluting stents and lesion characteristics: a study with serial coronary angioscopy. Yamamoto M; Okamatsu K; Inami S; Takano M; Yokoyama S; Ohba T; Ibuki C; Hata N; Seino Y; Mizuno K Am Heart J; 2009 Jul; 158(1):99-104. PubMed ID: 19540398 [TBL] [Abstract][Full Text] [Related]
15. [Optical coherence tomography for evaluation of neointimal proliferation after placement of a new drug eluting stent]. Liu CF; Chen YD; Chen L; Sun ZJ; Gai LY; Liu HB; Tian F; Bai QC; Guo K Nan Fang Yi Ke Da Xue Xue Bao; 2010 May; 30(5):1063-5. PubMed ID: 20501394 [TBL] [Abstract][Full Text] [Related]
16. Rapid Evaluation of Vessel HEaling After AngiopLasty (REVEAL) trial: rationale, objectives and design. Tamburino C; Capodanno D; La Manna A; di Salvo M; Sanfilippo A; Prati F J Cardiovasc Med (Hagerstown); 2010 Jan; 11(1):53-8. PubMed ID: 19829136 [TBL] [Abstract][Full Text] [Related]
17. Lack of clinical long-term benefit with the use of a drug eluting stent compared to use of a bare metal stent in saphenous vein grafts. Gioia G; Benassi A; Mohendra R; Chowdhury K; Masood I; Matthai W Catheter Cardiovasc Interv; 2008 Jul; 72(1):13-20. PubMed ID: 18561143 [TBL] [Abstract][Full Text] [Related]
18. [Clinical and angiographic outcome in coronary artery disease patients with type-II diabetes mellitus undergoing elective bare-metal stenting or drug-eluting stenting]. Qiao SB; Hou Q; Xu B; Chen J; Liu HB; Yang YJ; Wu YJ; Yuan JQ; Wu Y; Dai J; You SJ; Ma WH; Zhang P; Gao Z; Dou KF; Qiu H; Mu CW; Chen JL; Gao RL Zhonghua Xin Xue Guan Bing Za Zhi; 2007 Jun; 35(6):523-6. PubMed ID: 17711711 [TBL] [Abstract][Full Text] [Related]
19. Different vascular healing patterns with various drug-eluting stents in primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: optical coherence tomographic findings. Fan C; Kim JS; Lee JM; Kim TH; Park SM; Wi J; Paik SI; Ko YG; Choi D; Hong MK; Jang Y Am J Cardiol; 2010 Apr; 105(7):972-6. PubMed ID: 20346315 [TBL] [Abstract][Full Text] [Related]
20. Intra-stent tissue evaluation within bare metal and drug-eluting stents > 3 years since implantation in patients with mild to moderate neointimal proliferation using optical coherence tomography and virtual histology intravascular ultrasound. Kitabata H; Loh JP; Pendyala LK; Omar A; Ota H; Minha S; Magalhaes MA; Torguson R; Chen F; Satler LF; Pichard AD; Waksman R Cardiovasc Revasc Med; 2014 Apr; 15(3):149-55. PubMed ID: 24767313 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]