These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Successful use of continuous flow ventricular assist device in a patient with mechanical mitral and aortic valve prosthesis without replacement or exclusion of valves. Krishan K; Pinney S; Anyanwu AC Interact Cardiovasc Thorac Surg; 2010 Feb; 10(2):325-7. PubMed ID: 19948537 [TBL] [Abstract][Full Text] [Related]
3. Successful management of right ventricular failure with the ventricular assist pump following aortic valve replacement and coronary bypass grafting. O'Neill MJ; Pierce WS; Wisman CB; Osbakken MD; Parr GV; Waldhausen JA J Thorac Cardiovasc Surg; 1984 Jan; 87(1):106-11. PubMed ID: 6690848 [TBL] [Abstract][Full Text] [Related]
4. A case in which biventricular assist device support was required after aortic valve replacement with a bioprosthetic valve. Koizumi K; Yozu R; Shin H; Tsutsumi K; Enoki C; Iino Y; Matayoshi T; Morita M J Artif Organs; 2003; 6(3):218-21. PubMed ID: 14598107 [TBL] [Abstract][Full Text] [Related]
5. Long-term left ventricular support in patients with a mechanical aortic valve. Ahn H; Granfeldt H; Hübbert L; Peterzén B Scand Cardiovasc J; 2013 Aug; 47(4):236-9. PubMed ID: 23692166 [TBL] [Abstract][Full Text] [Related]
6. [A case report of biventricular assistance by means of ventricular assist device and IABP in postoperative biventricular failure]. Shimizu T; Aida H; Sakamoto S; Kaneto Y; Shirakawa H; Toyoda T Nihon Kyobu Geka Gakkai Zasshi; 1989 Jun; 37(6):1242-6. PubMed ID: 2809301 [TBL] [Abstract][Full Text] [Related]
7. Cardiac extracorporeal life support: state of the art in 2007. Cooper DS; Jacobs JP; Moore L; Stock A; Gaynor JW; Chancy T; Parpard M; Griffin DA; Owens T; Checchia PA; Thiagarajan RR; Spray TL; Ravishankar C Cardiol Young; 2007 Sep; 17 Suppl 2():104-15. PubMed ID: 18039404 [TBL] [Abstract][Full Text] [Related]
8. Improving outcomes with long-term "destination" therapy using left ventricular assist devices. Long JW; Healy AH; Rasmusson BY; Cowley CG; Nelson KE; Kfoury AG; Clayson SE; Reid BB; Moore SA; Blank DU; Renlund DG J Thorac Cardiovasc Surg; 2008 Jun; 135(6):1353-60; discussion 1360-1. PubMed ID: 18544385 [TBL] [Abstract][Full Text] [Related]
9. A novel use of the implantable ventricular assist device for isolated right heart failure. Osaki S; Edwards NM; Johnson MR; Kohmoto T Interact Cardiovasc Thorac Surg; 2008 Aug; 7(4):651-3. PubMed ID: 18492700 [TBL] [Abstract][Full Text] [Related]
10. Surgical considerations on the use of the percutaneous ventricular assist device TandemHeart in critical aortic valve stenosis. Loebe M; Zade Asfahani WH; Petrov GP; Kleiman NS; Torre-Amione G Thorac Cardiovasc Surg; 2009 Feb; 57(1):50-2. PubMed ID: 19169999 [TBL] [Abstract][Full Text] [Related]
11. Risk factor analysis for bridge to transplantation with the CardioWest total artificial heart. Copeland JG; Smith RG; Bose RK; Tsau PH; Nolan PE; Slepian MJ Ann Thorac Surg; 2008 May; 85(5):1639-44. PubMed ID: 18442554 [TBL] [Abstract][Full Text] [Related]
13. Multiple valve surgery with beating heart technique. Ricci M; Macedo FI; Suarez MR; Brown M; Alba J; Salerno TA Ann Thorac Surg; 2009 Feb; 87(2):527-31. PubMed ID: 19161773 [TBL] [Abstract][Full Text] [Related]