These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1066 related articles for article (PubMed ID: 16808581)

  • 1. Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys.
    Iijima M; Endo K; Yuasa T; Ohno H; Hayashi K; Kakizaki M; Mizoguchi I
    Angle Orthod; 2006 Jul; 76(4):705-11. PubMed ID: 16808581
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An investigation into the effects of polishing on surface hardness and corrosion of orthodontic archwires.
    Hunt NP; Cunningham SJ; Golden CG; Sheriff M
    Angle Orthod; 1999 Oct; 69(5):433-40. PubMed ID: 10515141
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro surface corrosion of stainless steel and NiTi orthodontic appliances.
    Shin JS; Oh KT; Hwang CJ
    Aust Orthod J; 2003 Apr; 19(1):13-8. PubMed ID: 12790351
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of galvanic corrosion potential of metal injection molded brackets to that of conventional metal brackets with nickel-titanium and copper nickel-titanium archwire combinations.
    Varma DP; Chidambaram S; Reddy KB; Vijay M; Ravindranath D; Prasad MR
    J Contemp Dent Pract; 2013 May; 14(3):488-95. PubMed ID: 24171995
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Nickel content of as-received and retrieved NiTi and stainless steel archwires: assessing the nickel release hypothesis.
    Eliades T; Zinelis S; Papadopoulos MA; Eliades G; Athanasiou AE
    Angle Orthod; 2004 Apr; 74(2):151-4. PubMed ID: 15132439
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Frictional resistances of different bracket-wire combinations.
    Kapur Wadhwa R; Kwon HK; Close JM
    Aust Orthod J; 2004 May; 20(1):25-30. PubMed ID: 15233584
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tribological behaviour of orthodontic archwires under dry and wet sliding conditions in-vitro. II--Wear patterns.
    Berradja A; Willems G; Celis JP
    Aust Orthod J; 2006 May; 22(1):21-9. PubMed ID: 16792242
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Static frictional force and surface roughness of nickel-titanium arch wires.
    Prososki RR; Bagby MD; Erickson LC
    Am J Orthod Dentofacial Orthop; 1991 Oct; 100(4):341-8. PubMed ID: 1927985
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An in vitro investigation of the influence of self-ligating brackets, low friction ligatures, and archwire on frictional resistance.
    Tecco S; Di Iorio D; Cordasco G; Verrocchi I; Festa F
    Eur J Orthod; 2007 Aug; 29(4):390-7. PubMed ID: 17702800
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys.
    Kapila S; Angolkar PV; Duncanson MG; Nanda RS
    Am J Orthod Dentofacial Orthop; 1990 Aug; 98(2):117-26. PubMed ID: 2378317
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of surface area ratios and bacteria on electrochemical behavior of galvanically coupled titanium.
    Koh I; Oshida Y; Andres CJ; Gregory RL
    Int J Prosthodont; 2008; 21(5):433-6. PubMed ID: 18950067
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.
    Yeung KW; Poon RW; Chu PK; Chung CY; Liu XY; Lu WW; Chan D; Chan SC; Luk KD; Cheung KM
    J Biomed Mater Res A; 2007 Aug; 82(2):403-14. PubMed ID: 17295246
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Static frictional force and surface roughness of various bracket and wire combinations.
    Doshi UH; Bhad-Patil WA
    Am J Orthod Dentofacial Orthop; 2011 Jan; 139(1):74-9. PubMed ID: 21195280
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Corrosion behavior of shape memory, superelastic, and nonsuperelastic nickel-titanium-based orthodontic wires at various temperatures.
    Pun DK; Berzins DW
    Dent Mater; 2008 Feb; 24(2):221-7. PubMed ID: 17624421
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Variations in surface characteristics and corrosion behaviour of metal brackets and wires in different electrolyte solutions.
    Kao CT; Huang TH
    Eur J Orthod; 2010 Oct; 32(5):555-60. PubMed ID: 20139132
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Friction of conventional and self-ligating brackets using a 10 bracket model.
    Tecco S; Festa F; Caputi S; Traini T; Di Iorio D; D'Attilio M
    Angle Orthod; 2005 Nov; 75(6):1041-5. PubMed ID: 16448253
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Relative kinetic frictional forces between sintered stainless steel brackets and orthodontic wires.
    Vaughan JL; Duncanson MG; Nanda RS; Currier GF
    Am J Orthod Dentofacial Orthop; 1995 Jan; 107(1):20-7. PubMed ID: 7817958
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The electrochemical behavior and surface analysis of Ti50Ni47.2Co2.8 alloy for orthodontic use.
    Wang QY; Zheng YF
    Dent Mater; 2008 Sep; 24(9):1207-11. PubMed ID: 18336899
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Galvanic coupling of steel and gold alloy lingual brackets with orthodontic wires: Is corrosion a concern?
    Polychronis G; Al Jabbari YS; Eliades T; Zinelis S
    Angle Orthod; 2018 Jul; 88(4):450-457. PubMed ID: 29509025
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the frictional coefficients for selected archwire-bracket slot combinations in the dry and wet states.
    Kusy RP; Whitley JQ; Prewitt MJ
    Angle Orthod; 1991; 61(4):293-302. PubMed ID: 1763840
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 54.