1629 related articles for article (PubMed ID: 16816436)
1. The utility of implantable loop recorders for diagnosing unexplained syncope in 100 consecutive patients: five-year, single-center experience.
Inamdar V; Mehta S; Juang G; Cohen T
J Invasive Cardiol; 2006 Jul; 18(7):313-5. PubMed ID: 16816436
[TBL] [Abstract][Full Text] [Related]
2. Initial clinical experience with implantable loop recorders.
Mieszczanska H; Ibrahim B; Cohen TJ
J Invasive Cardiol; 2001 Dec; 13(12):802-4. PubMed ID: 11731693
[TBL] [Abstract][Full Text] [Related]
3. How revealing are insertable loop recorders in pediatrics?
Frangini PA; Cecchin F; Jordao L; Martuscello M; Alexander ME; Triedman JK; Walsh EP; Berul CI
Pacing Clin Electrophysiol; 2008 Mar; 31(3):338-43. PubMed ID: 18307630
[TBL] [Abstract][Full Text] [Related]
4. Time to manual activation of implantable loop recorders--implications for programming recording period: a 10-year single-centre experience.
Turley AJ; Tynan MM; Plummer CJ
Europace; 2009 Oct; 11(10):1359-61. PubMed ID: 19648151
[TBL] [Abstract][Full Text] [Related]
5. High incidence of tachyarrhythmias detected by an implantable loop recorder in patients with unexplained syncope.
Schernthaner C; Danmayr F; Altenberger J; Pichler M; Strohmer B
Kardiol Pol; 2008 Jan; 66(1):37-44; discussion 45-6. PubMed ID: 18266186
[TBL] [Abstract][Full Text] [Related]
6. Are implantable loop recorders useful in detecting arrhythmias in children with unexplained syncope?
Al Dhahri KN; Potts JE; Chiu CC; Hamilton RM; Sanatani S
Pacing Clin Electrophysiol; 2009 Nov; 32(11):1422-7. PubMed ID: 19694968
[TBL] [Abstract][Full Text] [Related]
7. [Implantable loop recorders in evaluation of syncope].
Christiansen CS; Gjesdal K
Tidsskr Nor Laegeforen; 2007 Jun; 127(12):1657-9. PubMed ID: 17571107
[TBL] [Abstract][Full Text] [Related]
8. A retrospective study of the clinical experience of the implantable loop recorder in a paediatric setting.
Babikar A; Hynes B; Ward N; Oslizok P; Walsh K; Keane D
Int J Clin Pract; 2008 Oct; 62(10):1520-5. PubMed ID: 17764457
[TBL] [Abstract][Full Text] [Related]
9. The usage and diagnostic yield of the implantable loop-recorder in detection of the mechanism of syncope and in guiding effective antiarrhythmic therapy in older people.
Brignole M; Menozzi C; Maggi R; Solano A; Donateo P; Bottoni N; Lolli G; Quartieri F; Croci F; Oddone D; Puggioni E
Europace; 2005 May; 7(3):273-9. PubMed ID: 15878567
[TBL] [Abstract][Full Text] [Related]
10. Detection of asymptomatic arrhythmias in unexplained syncope.
Krahn AD; Klein GJ; Yee R; Skanes AC
Am Heart J; 2004 Aug; 148(2):326-32. PubMed ID: 15309004
[TBL] [Abstract][Full Text] [Related]
11. Incidence, diagnostic yield and safety of the implantable loop-recorder to detect the mechanism of syncope in patients with and without structural heart disease.
Solano A; Menozzi C; Maggi R; Donateo P; Bottoni N; Lolli G; Tomasi C; Croci F; Oddone D; Puggioni E; Brignole M
Eur Heart J; 2004 Jul; 25(13):1116-9. PubMed ID: 15231369
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of the diagnostic value of an implantable loop recorder in dogs with unexplained syncope.
Santilli RA; Ferasin L; Voghera SG; Perego M
J Am Vet Med Assoc; 2010 Jan; 236(1):78-82. PubMed ID: 20043804
[TBL] [Abstract][Full Text] [Related]
13. [Diagnostic yield of the implantable loop recorder to detect the mechanism of syncope--a single center long term experience of a tertiary care center].
Brunckhorst CB; Lemola K; Holzmeister J; Scharf Ch; Altwegg S; Binggeli Ch; Hellermann JP; Enseleit F; Duru F
Praxis (Bern 1994); 2005 Jan; 94(4):105-12. PubMed ID: 15732804
[TBL] [Abstract][Full Text] [Related]
14. [Long-term follow-up after implantable loop recorder in patients with syncope: results of a French general hospital survey].
Salih H; Monsel F; Sergent J; Amara W
Ann Cardiol Angeiol (Paris); 2012 Nov; 61(5):331-7. PubMed ID: 23062819
[TBL] [Abstract][Full Text] [Related]
15. Early application of an implantable loop recorder allows effective specific therapy in patients with recurrent suspected neurally mediated syncope.
Brignole M; Sutton R; Menozzi C; Garcia-Civera R; Moya A; Wieling W; Andresen D; Benditt DG; Vardas P;
Eur Heart J; 2006 May; 27(9):1085-92. PubMed ID: 16569653
[TBL] [Abstract][Full Text] [Related]
16. Use of implantable loop recorders in patients with Brugada syndrome and suspected risk of ventricular arrhythmia.
Kubala M; Aïssou L; Traullé S; Gugenheim AL; Hermida JS
Europace; 2012 Jun; 14(6):898-902. PubMed ID: 21979995
[TBL] [Abstract][Full Text] [Related]
17. Implantable loop recorder in unexplained syncope: classification, mechanism, transient loss of consciousness and role of major depressive disorder in patients with and without structural heart disease.
Pezawas T; Stix G; Kastner J; Schneider B; Wolzt M; Schmidinger H
Heart; 2008 Apr; 94(4):e17. PubMed ID: 17947364
[TBL] [Abstract][Full Text] [Related]
18. Predictive value of presyncope in patients monitored for assessment of syncope.
Krahn AD; Klein GJ; Yee R; Skanes AC;
Am Heart J; 2001 May; 141(5):817-21. PubMed ID: 11320372
[TBL] [Abstract][Full Text] [Related]
19. [Efficacy of implantable loop recorders in establishing symptom-rhythm correlation in patients with unexplained syncope].
Liu ZM; Liu ZP; Guo T
Zhonghua Xin Xue Guan Bing Za Zhi; 2006 Nov; 34(11):1009-12. PubMed ID: 17288766
[TBL] [Abstract][Full Text] [Related]
20. The dual role of implantable loop recorder in patients with potentially arrhythmic symptoms: a retrospective single-center study.
Kabra R; Gopinathannair R; Sandesara C; Messinger C; Olshansky B
Pacing Clin Electrophysiol; 2009 Jul; 32(7):908-12. PubMed ID: 19572867
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]