These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

240 related articles for article (PubMed ID: 16819697)

  • 21. [Minimally invasive percutaneous locking compression plate internal fixation in the treatment of tibial fractures].
    Zha G; Chen Z; Qi X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Dec; 22(12):1448-50. PubMed ID: 19137887
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Percutaneous plating of distal tibial fractures in children and adolescents.
    Masquijo JJ
    J Pediatr Orthop B; 2014 May; 23(3):207-11. PubMed ID: 24500423
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Minimally invasive percutaneous plate fixation of distal tibia fractures.
    Bahari S; Lenehan B; Khan H; McElwain JP
    Acta Orthop Belg; 2007 Oct; 73(5):635-40. PubMed ID: 18019921
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Minimally invasive percutaneous plate osteosynthesis versus open reduction and internal fixation for distal tibial fractures in adults: a meta-analysis].
    Zhang QX; Gao FQ; Sun W; Wang YT; Yang YR; Li Z
    Zhongguo Gu Shang; 2015 Aug; 28(8):757-62. PubMed ID: 26502532
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Percutaneous plating for unstable tibial fractures.
    Oh CW; Park BC; Kyung HS; Kim SJ; Kim HS; Lee SM; Ihn JC
    J Orthop Sci; 2003; 8(2):166-9. PubMed ID: 12665952
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Minimally invasive locking plate osteosynthesis for fractures of the distal tibia--results in 20 patients.
    Hazarika S; Chakravarthy J; Cooper J
    Injury; 2006 Sep; 37(9):877-87. PubMed ID: 16895727
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Bridging-minimally invasive locking plate osteosynthesis (Bridging-MILPO): technique description with prospective series of 20 tibial fractures.
    Williams TH; Schenk W
    Injury; 2008 Oct; 39(10):1198-203. PubMed ID: 18703185
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Minimally invasive percutaneous plate osteosynthesis of fractures of the distal tibia.
    Helfet DL; Suk M
    Instr Course Lect; 2004; 53():471-5. PubMed ID: 15116635
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Minimally invasive plating of high-energy metaphyseal distal tibia fractures.
    Collinge C; Kuper M; Larson K; Protzman R
    J Orthop Trauma; 2007 Jul; 21(6):355-61. PubMed ID: 17620992
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.
    Ma CH; Tu YK; Yeh JH; Yang SC; Wu CH
    J Trauma; 2011 Sep; 71(3):614-9. PubMed ID: 21768910
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Curative effect of minimally invasive percutaneous plate osteosynthesis assisted by arthroscopy on 29 cases of tibial plateau fractures].
    Tian M; Wang L; Zhang Y; Liu J
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Aug; 23(8):921-4. PubMed ID: 19728606
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Advantages of minimally-invasive reposition, retention, and Ilizarov-(hybrid)fixation for pilon-tibial-fractures fractures with particular emphasis on C2/C3 fractures].
    Endres T; Grass R; Biewener A; Barthel S; Zwipp H
    Unfallchirurg; 2004 Apr; 107(4):273-84. PubMed ID: 15048331
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Successful treatment of infected wound dehiscence after minimally invasive locking-plate osteosynthesis of tibial pilon and calcaneal fractures by plate preservation, surgical debridement and antibiotics.
    Ieropoli G; Villafañe JH; Zompi SC; Morozzo U; D'Ambrosi R; Usuelli FG; Berjano P
    Foot (Edinb); 2017 Dec; 33():44-47. PubMed ID: 29126042
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Prospective evaluation of minimally invasive plate osteosynthesis in 36 nonarticular tibial fractures in dogs and cats.
    Guiot LP; Déjardin LM
    Vet Surg; 2011 Feb; 40(2):171-82. PubMed ID: 21223316
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Minimally invasive percutaneous plate osteosynthesis for closed distal tibial fractures: a consecutive study based on 25 patients.
    Bhat R; Wani MM; Rashid S; Akhter N
    Eur J Orthop Surg Traumatol; 2015 Apr; 25(3):563-8. PubMed ID: 25238896
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Open reduction and internal fixation better than percutaneous plate osteosynthesis in distal tibial fractures.
    Zou J; Shi ZM; Zhang W; Zhang CQ
    J Invest Surg; 2012 Oct; 25(5):326-9. PubMed ID: 22612244
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Minimally Invasive Versus Open Distal Fibular Plating for AO/OTA 44-B Ankle Fractures.
    Chiang CC; Tzeng YH; Lin CC; Huang CK; Chang MC
    Foot Ankle Int; 2016 Jun; 37(6):611-9. PubMed ID: 26740306
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Plating of humeral shaft fractures: comparison of standard conventional plating versus minimally invasive plating.
    Oh CW; Byun YS; Oh JK; Kim JJ; Jeon IH; Lee JH; Park KH
    Orthop Traumatol Surg Res; 2012 Feb; 98(1):54-60. PubMed ID: 22204793
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Limited Open Reduction and Percutaneous Plate Osteosynthesis - Alternative Option to Minimally Invasive Plate Osteosynthesis in Management of Distal Tibia Fractures.
    Sah S; Bikash KC; Dangi SJ; Rai RK; Yadav R
    JNMA J Nepal Med Assoc; 2017; 56(208):456-60. PubMed ID: 29453480
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A case report of Schatzker type VI tibial plateau fracture treated with double reverse traction closed reduction combined with minimally invasive percutaneous plate osteosynthesis technique: A case report.
    Li DQ; Song DY; Ni JD; Ding ML; Huang J
    Medicine (Baltimore); 2017 Nov; 96(45):e8394. PubMed ID: 29137023
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.