These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 16820803)

  • 21. Post-gel shrinkage with pulse activation and soft-start polymerization.
    Yap AU; Soh MS; Siow KS
    Oper Dent; 2002; 27(1):81-7. PubMed ID: 11822366
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of stepped light exposure on the volumetric polymerization shrinkage and bulk modulus of dental composites and an unfilled resin.
    Price RB; Rizkalla AS; Hall GC
    Am J Dent; 2000 Aug; 13(4):176-80. PubMed ID: 11763926
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of light curing units on marginal adaptation and hardness of Class II composite resin restorations.
    Cavalcante LM; Peris AR; Silikas N; Pimenta LA
    J Contemp Dent Pract; 2007 Nov; 8(7):38-45. PubMed ID: 17994153
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of high intensity vs. soft-start halogen irradiation on light-cured resin-based composites. Part II: Hardness and solubility.
    Hofmann N; Markert T; Hugo B; Klaiber B
    Am J Dent; 2004 Feb; 17(1):38-42. PubMed ID: 15241908
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Effects of light-curing modes on the polymerization shrinkage and surface hardness of composite resins].
    Han B; Dong YM; Wang XY; Gao XJ
    Beijing Da Xue Xue Bao Yi Xue Ban; 2011 Oct; 43(5):770-3. PubMed ID: 22008694
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of PAC and QTH light sources on polymerization of resin composites.
    Katahira N; Foxton RM; Inai N; Otsuki M; Tagami J
    Am J Dent; 2004 Apr; 17(2):113-7. PubMed ID: 15151338
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Increases in intrapulpal temperature during polymerization of composite resin.
    Martins GR; Cavalcanti BN; Rode SM
    J Prosthet Dent; 2006 Nov; 96(5):328-31. PubMed ID: 17098495
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Polymerization shrinkage of composite resins using plasma-arc photocuring.
    Aw TC; Nicholls JI
    Gen Dent; 2001; 49(5):473-9. PubMed ID: 12017790
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Guidance of shrinkage vectors vs irradiation at reduced intensity for improving marginal seal of class V resin-based composite restorations in vitro.
    Hofmann N; Hiltl O; Hugo B; Klaiber B
    Oper Dent; 2002; 27(5):510-5. PubMed ID: 12216571
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Immediate polymerization shrinkage in light cured restorative resins.
    Rodríguez VI; Abate PF; Macchi RL
    Acta Odontol Latinoam; 2006; 19(1):3-7. PubMed ID: 17121192
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Post-gel polymerization contraction of "low shrinkage" composite restoratives.
    Yap AU; Soh MS
    Oper Dent; 2004; 29(2):182-7. PubMed ID: 15088730
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A review of polymerization shrinkage stress: current techniques for posterior direct resin restorations.
    Giachetti L; Scaminaci Russo D; Bambi C; Grandini R
    J Contemp Dent Pract; 2006 Sep; 7(4):79-88. PubMed ID: 16957794
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Soft-start polymerization: influence on effectiveness of cure and post-gel shrinkage.
    Yap AU; Ng SC; Siow KS
    Oper Dent; 2001; 26(3):260-6. PubMed ID: 11357568
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Axial shrinkage-stress depends upon both C-factor and composite mass.
    Watts DC; Satterthwaite JD
    Dent Mater; 2008 Jan; 24(1):1-8. PubMed ID: 17920115
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of pre-heating on depth of cure and surface hardness of light-polymerized resin composites.
    Muñoz CA; Bond PR; Sy-Muñoz J; Tan D; Peterson J
    Am J Dent; 2008 Aug; 21(4):215-22. PubMed ID: 18795516
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Hardness and wear resistance of two resin composites cured with equivalent radiant exposure from a low irradiance LED and QTH light-curing units.
    Ramp LC; Broome JC; Ramp MH
    Am J Dent; 2006 Feb; 19(1):31-6. PubMed ID: 16555655
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Pre-heating of high-viscosity bulk-fill resin composites: effects on shrinkage force and monomer conversion.
    Tauböck TT; Tarle Z; Marovic D; Attin T
    J Dent; 2015 Nov; 43(11):1358-64. PubMed ID: 26232610
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Calculation of contraction rates due to shrinkage in light-cured composites.
    Alvarez-Gayosso C; Barceló-Santana F; Guerrero-Ibarra J; Sáez-Espínola G; Canseco-Martínez MA
    Dent Mater; 2004 Mar; 20(3):228-35. PubMed ID: 15214308
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Properties of silorane-based dental resins and composites containing a stress-reducing monomer.
    Eick JD; Kotha SP; Chappelow CC; Kilway KV; Giese GJ; Glaros AG; Pinzino CS
    Dent Mater; 2007 Aug; 23(8):1011-7. PubMed ID: 17097138
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effect of preheating resin composite and light-curing units on the microleakage of Class II restorations submitted to thermocycling.
    dos Santos RE; Lima AF; Soares GP; Ambrosano GM; Marchi GM; Lovadino JR; Aguiar FH
    Oper Dent; 2011; 36(1):60-5. PubMed ID: 21488730
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.