159 related articles for article (PubMed ID: 16824969)
1. Motion correction properties of the shells k-space trajectory.
Shu Y; Elliott AM; Riederer SJ; Bernstein MA
Magn Reson Imaging; 2006 Jul; 24(6):739-49. PubMed ID: 16824969
[TBL] [Abstract][Full Text] [Related]
2. High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions.
Li TQ; Kim DH; Moseley ME
J Magn Reson Imaging; 2005 Apr; 21(4):468-75. PubMed ID: 15779030
[TBL] [Abstract][Full Text] [Related]
3. MRI with TRELLIS: a novel approach to motion correction.
Maclaren JR; Bones PJ; Millane RP; Watts R
Magn Reson Imaging; 2008 May; 26(4):474-83. PubMed ID: 18068932
[TBL] [Abstract][Full Text] [Related]
4. Retrospective motion compensation using variable-density spiral trajectories.
Leung G; Plewes DB
J Magn Reson Imaging; 2005 Sep; 22(3):373-80. PubMed ID: 16104023
[TBL] [Abstract][Full Text] [Related]
5. Online motion correction for diffusion-weighted segmented-EPI and FLASH imaging.
Weih KS; Driesel W; von Mengershausen M; Norris DG
MAGMA; 2004 May; 16(6):277-83. PubMed ID: 15052418
[TBL] [Abstract][Full Text] [Related]
6. k-space inherited parallel acquisition (KIPA): application on dynamic magnetic resonance imaging thermometry.
Guo JY; Kholmovski EG; Zhang L; Jeong EK; Parker DL
Magn Reson Imaging; 2006 Sep; 24(7):903-15. PubMed ID: 16916708
[TBL] [Abstract][Full Text] [Related]
7. K-space and image-space combination for motion-induced phase-error correction in self-navigated multicoil multishot DWI.
Van AT; Karampinos DC; Georgiadis JG; Sutton BP
IEEE Trans Med Imaging; 2009 Nov; 28(11):1770-80. PubMed ID: 19884065
[TBL] [Abstract][Full Text] [Related]
8. Improved optimization strategies for autofocusing motion compensation in MRI via the analysis of image metric maps.
Lin W; Song HK
Magn Reson Imaging; 2006 Jul; 24(6):751-60. PubMed ID: 16824970
[TBL] [Abstract][Full Text] [Related]
9. Spiral imaging artifact reduction: a comparison of two k-trajectory measurement methods.
Lechner SM; Sipilä PT; Wiesinger F; Kerr AB; Vogel MW
J Magn Reson Imaging; 2009 Jun; 29(6):1485-92. PubMed ID: 19472426
[TBL] [Abstract][Full Text] [Related]
10. Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion.
Atkinson D; Hill DL; Stoyle PN; Summers PE; Keevil SF
IEEE Trans Med Imaging; 1997 Dec; 16(6):903-10. PubMed ID: 9533590
[TBL] [Abstract][Full Text] [Related]
11. [Inverse iterative correction for translational motion artifact of magnetic resonance imaging based on histogram entropy minimization].
Jiang GP; Chen WF; Hou ZS
Di Yi Jun Yi Da Xue Xue Bao; 2005 Jun; 25(6):655-9. PubMed ID: 15958301
[TBL] [Abstract][Full Text] [Related]
12. TSE with average-specific phase encoding ordering for motion detection and artifact suppression.
Zhang L; Kholmovski EG; Guo J; Parker DL
J Magn Reson Imaging; 2007 Jun; 25(6):1271-82. PubMed ID: 17520734
[TBL] [Abstract][Full Text] [Related]
13. [Software for MR image reconstruction from data acquired on an irregular k-space trajectory].
Qian Y; Liu L; Xu K; Lin J
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Jun; 20(2):322-4, 327. PubMed ID: 12856610
[TBL] [Abstract][Full Text] [Related]
14. RINGLET motion correction for 3D MRI acquired with the elliptical centric view order.
Bernstein MA; Shu Y; Elliott AM
Magn Reson Med; 2003 Oct; 50(4):802-12. PubMed ID: 14523967
[TBL] [Abstract][Full Text] [Related]
15. Field inhomogeneity correction based on gridding reconstruction for magnetic resonance imaging.
Eggers H; Knopp T; Potts D
IEEE Trans Med Imaging; 2007 Mar; 26(3):374-84. PubMed ID: 17354642
[TBL] [Abstract][Full Text] [Related]
16. Parallel imaging with 3D TPI trajectory: SNR and acceleration benefits.
Qian Y; Stenger VA; Boada FE
Magn Reson Imaging; 2009 Jun; 27(5):656-63. PubMed ID: 19110392
[TBL] [Abstract][Full Text] [Related]
17. A rapid look-up table method for reconstructing MR images from arbitrary K-space trajectories.
Dale B; Wendt M; Duerk JL
IEEE Trans Med Imaging; 2001 Mar; 20(3):207-17. PubMed ID: 11341710
[TBL] [Abstract][Full Text] [Related]
18. Non-model-based correction of respiratory motion using beat-to-beat 3D spiral fat-selective imaging.
Keegan J; Gatehouse PD; Yang GZ; Firmin DN
J Magn Reson Imaging; 2007 Sep; 26(3):624-9. PubMed ID: 17729350
[TBL] [Abstract][Full Text] [Related]
19. Novel interleaved spiral imaging motion correction technique using orbital navigators.
Moriguchi H; Lewin JS; Duerk JL
Magn Reson Med; 2003 Aug; 50(2):423-8. PubMed ID: 12876721
[TBL] [Abstract][Full Text] [Related]
20. Implementation of helical computed tomography in magnetic resonance imaging.
Azhari H; Rosenthal S; Montag A
J Magn Reson Imaging; 2003 Oct; 18(4):478-86. PubMed ID: 14508785
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]