These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 16827489)

  • 1. The radon-split method for helical cone-beam CT and its application to nongated reconstruction.
    Köhler T; Bontus C; Koken P
    IEEE Trans Med Imaging; 2006 Jul; 25(7):882-97. PubMed ID: 16827489
    [TBL] [Abstract][Full Text] [Related]  

  • 2. EnPiT: filtered back-projection algorithm for helical CT using an n-Pi acquisition.
    Bontus C; Köhler T; Proksa R
    IEEE Trans Med Imaging; 2005 Aug; 24(8):977-86. PubMed ID: 16092330
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A reconstruction algorithm for helical CT imaging on PI-planes.
    Liang H; Zhang C; Yan M
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():2534-7. PubMed ID: 17945720
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CEnPiT: helical cardiac CT reconstruction.
    Bontus C; Koken P; Köhler T; Grass M
    Med Phys; 2006 Aug; 33(8):2792-9. PubMed ID: 16964855
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A filtered backprojection algorithm for cone beam reconstruction using rotational filtering under helical source trajectory.
    Tang X; Hsieh J
    Med Phys; 2004 Nov; 31(11):2949-60. PubMed ID: 15587646
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A novel extension of the parallel-beam projection-slice theorem to divergent fan-beam and cone-beam projections.
    Chen GH; Leng S; Mistretta CA
    Med Phys; 2005 Mar; 32(3):654-65. PubMed ID: 15839337
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A quasiexact reconstruction algorithm for helical CT using a 3-Pi acquisition.
    Bontus C; Köhler T; Proksa R
    Med Phys; 2003 Sep; 30(9):2493-502. PubMed ID: 14528971
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Handling of long objects in iterative improvement of nonexact reconstruction in helical cone-beam CT.
    Magnusson M; Danielsson PE; Sunnegårdh J
    IEEE Trans Med Imaging; 2006 Jul; 25(7):935-40. PubMed ID: 16827493
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Handling data redundancy in helical cone beam reconstruction with a cone-angle-based window function and its asymptotic approximation.
    Tang X; Hsieh J
    Med Phys; 2007 Jun; 34(6):1989-98. PubMed ID: 17654902
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT-helical scanning.
    Tang X; Hsieh J; Nilsen RA; Dutta S; Samsonov D; Hagiwara A
    Phys Med Biol; 2006 Feb; 51(4):855-74. PubMed ID: 16467583
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fully truncated cone-beam reconstruction on Pi lines using prior CT.
    Ramamurthi K; Strobel N; Fahrig R; Prince JL
    Med Image Comput Comput Assist Interv; 2005; 8(Pt 1):631-8. PubMed ID: 16685899
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Feldkamp-based cone-beam reconstruction for gantry-tilted helical multislice CT.
    Hein I; Taguchi K; Silver MD; Kazama M; Mori I
    Med Phys; 2003 Dec; 30(12):3233-42. PubMed ID: 14713090
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans.
    Pan X; Xia D; Zou Y; Yu L
    Phys Med Biol; 2004 Sep; 49(18):4349-69. PubMed ID: 15509070
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Minimum data image reconstruction algorithms with shift-invariant filtering for helical, cone-beam CT.
    Sidky EY; Zou Y; Pan X
    Phys Med Biol; 2005 Apr; 50(8):1643-57. PubMed ID: 15815087
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Compensation of some time dependent deformations in tomography.
    Desbat L; Roux S; Grangeat P
    IEEE Trans Med Imaging; 2007 Feb; 26(2):261-9. PubMed ID: 17304739
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Partial volume and aliasing artefacts in helical cone-beam CT.
    Zou Y; Sidky EY; Pan X
    Phys Med Biol; 2004 Jun; 49(11):2365-75. PubMed ID: 15248583
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of polychromatic x-ray sources on helical, cone-beam computed tomography and dual-energy methods.
    Sidky EY; Zou Y; Pan X
    Phys Med Biol; 2004 Jun; 49(11):2293-303. PubMed ID: 15248578
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A shift-invariant filtered backprojection (FBP) cone-beam reconstruction algorithm for the source trajectory of two concentric circles using an equal weighting scheme.
    Zhuang T; Nett BE; Leng S; Chen GH
    Phys Med Biol; 2006 Jun; 51(12):3189-210. PubMed ID: 16757871
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT.
    Zou Y; Pan X
    Phys Med Biol; 2004 Mar; 49(6):941-59. PubMed ID: 15104318
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT.
    Zou Y; Pan X
    Phys Med Biol; 2004 Jun; 49(12):2717-31. PubMed ID: 15272684
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.