These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

251 related articles for article (PubMed ID: 16837134)

  • 1. Hemostasis by means of a cautery knife equipped with an air spray for burns over a large area.
    Mitsukawa N; Satoh K; Hosaka Y
    Burns; 2006 Sep; 32(6):695-7. PubMed ID: 16837134
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Device related tangential excision in burns.
    Jeffery SL
    Injury; 2007 Dec; 38 Suppl 5():S35-8. PubMed ID: 18061188
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Grid escharotomy for debriding burns.
    Richards KE; Feller I
    Surg Gynecol Obstet; 1973 Nov; 137(5):843-4. PubMed ID: 4746507
    [No Abstract]   [Full Text] [Related]  

  • 4. Tumescent technique for burn wound debridement: a cost effective method of reducing transfusion requirements.
    Husain S; Ofodile FA
    J Coll Physicians Surg Pak; 2006 Mar; 16(3):227-8. PubMed ID: 16542607
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Use of the CO2 laser in the treatment of burn injuries].
    Zellner PR; Lazaridis C; Möller I; Königsmann G
    Z Plast Chir; 1979 Sep; 3(3):138-46. PubMed ID: 524994
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reducing blood loss in total joint surgery with a saline-coupled bipolar sealing technology.
    Rosenberg AG
    J Arthroplasty; 2007 Jun; 22(4 Suppl 1):82-5. PubMed ID: 17570284
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Novel hemostatic devices in thyroid surgery: electrothermal bipolar vessel sealing system and harmonic scalpel.
    Manouras A; Markogiannakis HE; Kekis PB; Lagoudianakis EE; Fleming B
    Expert Rev Med Devices; 2008 Jul; 5(4):447-66. PubMed ID: 18573045
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [2 types of equipment designed for management of burns].
    Cheng HZ
    Zhonghua Wai Ke Za Zhi; 1983 Mar; 21(3):183-4. PubMed ID: 6872762
    [No Abstract]   [Full Text] [Related]  

  • 9. [Clinical experiences using the Versajet system in burns: indications and applications].
    Rappl T; Regauer S; Wiedner M; Wittgruber G; Schintler M; Scharnagl E
    Handchir Mikrochir Plast Chir; 2007 Oct; 39(5):308-13. PubMed ID: 17985272
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A novel device for intraoperative cauterization of bleeding points in endoscopic sinus surgery.
    Pagella F; Pusateri A; Berardi A; Zaccari D; Avato I; Matti E
    Eur Arch Otorhinolaryngol; 2016 Aug; 273(8):2257-60. PubMed ID: 27216302
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Innovations in microdebrider technology and design.
    Bruggers S; Sindwani R
    Otolaryngol Clin North Am; 2009 Oct; 42(5):781-7, viii. PubMed ID: 19909858
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A microbipolar cautery for use in the middle ear.
    House JL
    Otolaryngol Head Neck Surg; 1985 Feb; 93(1):134-5. PubMed ID: 3920613
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bleeding during dacryocystorhinostomy: the importance of the suction cautery.
    Small RG; Reed J
    Arch Ophthalmol; 1990 May; 108(5):638-9. PubMed ID: 2334317
    [No Abstract]   [Full Text] [Related]  

  • 14. Treatment of deep partial thickness and indeterminate depth facial burn wounds with water-jet debridement and a biosynthetic dressing.
    Tenenhaus M; Bhavsar D; Rennekampff HO
    Injury; 2007 Dec; 38 Suppl 5():S39-45. PubMed ID: 18061187
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tourniquet technique for reduced blood loss and wound assessment during excisions of burn wounds of the extremity.
    Marano MA; O'Sullivan G; Madden M; Finkelstein J; Goodwin CW
    Surg Gynecol Obstet; 1990 Sep; 171(3):249-50. PubMed ID: 2385817
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A hemostatic scalpel for burn debridement.
    Levenson SM; Gruber DK; Gruber C; Seifter E; Molnar J; Petro J
    Arch Surg; 1982 Feb; 117(2):213-20. PubMed ID: 7034681
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tangential excision of burn wounds.
    Choi M; Panthaki ZJ
    J Craniofac Surg; 2008 Jul; 19(4):1056-60. PubMed ID: 18650732
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Surgical cautery revisited.
    Keenan KM; Rodeheaver GT; Kenney JG; Edlich RF
    Am J Surg; 1984 Jun; 147(6):818-21. PubMed ID: 6731701
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimization of thermocautery in excisional dermatologic surgery.
    Lane JE; O'brien EM; Kent DE
    Dermatol Surg; 2006 May; 32(5):669-75. PubMed ID: 16706762
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Two-surgeon technique using saline-linked electric cautery and ultrasonic surgical aspirator in living donor hepatectomy: its safety and efficacy.
    Takatsuki M; Eguchi S; Yamanouchi K; Tokai H; Hidaka M; Soyama A; Miyazaki K; Hamasaki K; Tajima Y; Kanematsu T
    Am J Surg; 2009 Feb; 197(2):e25-7. PubMed ID: 18639230
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.