These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 16840598)

  • 1. Calibration of infrared milk analyzers: modified milk versus producer milk.
    Kaylegian KE; Houghton GE; Lynch JM; Fleming JR; Barbano DM
    J Dairy Sci; 2006 Aug; 89(8):2817-32. PubMed ID: 16840598
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Modified versus producer milk calibration: mid-infrared analyzer performance validation.
    Kaylegian KE; Lynch JM; Houghton GE; Fleming JR; Barbano DM
    J Dairy Sci; 2006 Aug; 89(8):2833-45. PubMed ID: 16840599
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lipolysis and proteolysis of modified and producer milks used for calibration of mid-infrared milk analyzers.
    Kaylegian KE; Lynch JM; Fleming JR; Barbano DM
    J Dairy Sci; 2007 Feb; 90(2):602-15. PubMed ID: 17235136
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of preservatives on the accuracy of mid-infrared milk component testing.
    Barbano DM; Wojciechowski KL; Lynch JM
    J Dairy Sci; 2010 Dec; 93(12):6000-11. PubMed ID: 21094775
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Precalibration evaluation procedures for mid-infrared milk analyzers.
    Lynch JM; Barbano DM; Schweisthal M; Fleming JR
    J Dairy Sci; 2006 Jul; 89(7):2761-74. PubMed ID: 16772596
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Infrared estimation of fat, protein, and lactose in milk: evaluation of multispec instrument.
    Biggs DA
    J Assoc Off Anal Chem; 1979 Nov; 62(6):1202-7. PubMed ID: 521407
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance specifications for infrared milk analysis.
    Biggs DA
    J Assoc Off Anal Chem; 1979 Nov; 62(6):1211-4. PubMed ID: 521408
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Robustness of near-infrared calibration models for the prediction of milk constituents during the milking process.
    Melfsen A; Hartung E; Haeussermann A
    J Dairy Res; 2013 Feb; 80(1):103-12. PubMed ID: 23182024
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mid-infrared spectrometry of milk for dairy metabolomics: a comparison of two sampling techniques and effect of homogenization.
    Aernouts B; Polshin E; Saeys W; Lammertyn J
    Anal Chim Acta; 2011 Oct; 705(1-2):88-97. PubMed ID: 21962352
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of fat, protein, and lactose in raw milk by Fourier transform infrared spectroscopy and by analysis with a conventional filter-based milk analyzer.
    Lefier D; Grappin R; Pochet S
    J AOAC Int; 1996; 79(3):711-7. PubMed ID: 8634540
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of fatty acid chain length and unsaturation on mid-infrared milk analysis.
    Kaylegian KE; Lynch JM; Fleming JR; Barbano DM
    J Dairy Sci; 2009 Jun; 92(6):2485-501. PubMed ID: 19447980
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Instrumental infrared estimation of fat, protein, and lactose in milk: collaborative study.
    Biggs DA
    J Assoc Off Anal Chem; 1978 Sep; 61(5):1015-34. PubMed ID: 721718
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Potential and limitation of mid-infrared attenuated total reflectance spectroscopy for real time analysis of raw milk in milking lines.
    Linker R; Etzion Y
    J Dairy Res; 2009 Feb; 76(1):42-8. PubMed ID: 18925993
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Milk analysis using milk analyzers in a standardized setting (MAMAS) study: A multicentre quality initiative.
    Kwan C; Fusch G; Rochow N; Fusch C;
    Clin Nutr; 2020 Jul; 39(7):2121-2128. PubMed ID: 31526612
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Potential estimation of major mineral contents in cow milk using mid-infrared spectrometry.
    Soyeurt H; Bruwier D; Romnee JM; Gengler N; Bertozzi C; Veselko D; Dardenne P
    J Dairy Sci; 2009 Jun; 92(6):2444-54. PubMed ID: 19447976
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Infrared milk analyzers: Milk urea nitrogen calibration.
    Portnoy M; Coon C; Barbano DM
    J Dairy Sci; 2021 Jul; 104(7):7426-7437. PubMed ID: 33814152
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of microbiological testing on subsequent mid-infrared milk component analysis of the same milk sample.
    Wojciechowski KL; Melilli C; Barbano DM
    J Dairy Sci; 2014 Sep; 97(9):5885-97. PubMed ID: 25022674
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impact of CO2 addition to milk on selected analytical testing methods.
    Ma Y; Barbano DM; Hotchkiss JH; Murphy S; Lynch JM
    J Dairy Sci; 2001 Sep; 84(9):1959-68. PubMed ID: 11573774
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Genetic variability of lactoferrin content estimated by mid-infrared spectrometry in bovine milk.
    Soyeurt H; Colinet FG; Arnould VM; Dardenne P; Bertozzi C; Renaville R; Portetelle D; Gengler N
    J Dairy Sci; 2007 Sep; 90(9):4443-50. PubMed ID: 17699065
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Visible and near-infrared spectroscopic analysis of raw milk for cow health monitoring: reflectance or transmittance?
    Aernouts B; Polshin E; Lammertyn J; Saeys W
    J Dairy Sci; 2011 Nov; 94(11):5315-29. PubMed ID: 22032354
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.