228 related articles for article (PubMed ID: 16842610)
1. A study of the dispersion of expiratory aerosols in unidirectional downward and ceiling-return type airflows using a multiphase approach.
Chao CY; Wan MP
Indoor Air; 2006 Aug; 16(4):296-312. PubMed ID: 16842610
[TBL] [Abstract][Full Text] [Related]
2. Transport characteristics of expiratory droplets and droplet nuclei in indoor environments with different ventilation airflow patterns.
Wan MP; Chao CY
J Biomech Eng; 2007 Jun; 129(3):341-53. PubMed ID: 17536901
[TBL] [Abstract][Full Text] [Related]
3. Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation.
Chen C; Zhao B
Indoor Air; 2010 Apr; 20(2):95-111. PubMed ID: 20002792
[TBL] [Abstract][Full Text] [Related]
4. Pollutant dispersion in a large indoor space: Part 1 -- Scaled experiments using a water-filled model with occupants and furniture.
Thatcher TL; Wilson DJ; Wood EE; Craig MJ; Sextro RG
Indoor Air; 2004 Aug; 14(4):258-71. PubMed ID: 15217479
[TBL] [Abstract][Full Text] [Related]
5. Experimental methods to determine inhalability and personal sampler performance for aerosols in ultra-low windspeed environments.
Schmees DK; Wu YH; Vincent JH
J Environ Monit; 2008 Dec; 10(12):1426-36. PubMed ID: 19037484
[TBL] [Abstract][Full Text] [Related]
6. Transport of surgically produced aerosols in an operating room.
Buchanan CR; Dunn-Rankin D
Am Ind Hyg Assoc J; 1998 Jun; 59(6):393-402. PubMed ID: 9670469
[TBL] [Abstract][Full Text] [Related]
7. A methodology for estimating airborne virus exposures in indoor environments using the spatial distribution of expiratory aerosols and virus viability characteristics.
Sze To GN; Wan MP; Chao CY; Wei F; Yu SC; Kwan JK
Indoor Air; 2008 Oct; 18(5):425-38. PubMed ID: 18691266
[TBL] [Abstract][Full Text] [Related]
8. Numerical investigation and recommendations for push-pull ventilation systems.
Chern MJ; Ma CH
J Occup Environ Hyg; 2007 Mar; 4(3):184-97. PubMed ID: 17237024
[TBL] [Abstract][Full Text] [Related]
9. Transport of airborne particles within a room.
Richmond-Bryant J; Eisner AD; Brixey LA; Wiener RW
Indoor Air; 2006 Feb; 16(1):48-55. PubMed ID: 16420497
[TBL] [Abstract][Full Text] [Related]
10. Airborne respiratory aerosol transport and deposition in a two-person office using a novel diffusion-based numerical model.
Obeid S; White P; Rosati Rowe J; Ilacqua V; Rawat MS; Ferro AR; Ahmadi G
J Expo Sci Environ Epidemiol; 2024 Mar; 34(2):356-375. PubMed ID: 37337048
[TBL] [Abstract][Full Text] [Related]
11. Validating CFD predictions of respiratory aerosol deposition: effects of upstream transition and turbulence.
Worth Longest P; Vinchurkar S
J Biomech; 2007; 40(2):305-16. PubMed ID: 16533511
[TBL] [Abstract][Full Text] [Related]
12. Exhaled air dispersion and removal is influenced by isolation room size and ventilation settings during oxygen delivery via nasal cannula.
Hui DS; Chow BK; Chu L; Ng SS; Lai ST; Gin T; Chan MT
Respirology; 2011 Aug; 16(6):1005-13. PubMed ID: 21605275
[TBL] [Abstract][Full Text] [Related]
13. Assessing Effectiveness of Ceiling-Ventilated Mock Airborne Infection Isolation Room in Preventing Hospital-Acquired Influenza Transmission to Health Care Workers.
Thatiparti DS; Ghia U; Mead KR
ASHRAE Trans; 2016; 122(2):35-46. PubMed ID: 28529344
[TBL] [Abstract][Full Text] [Related]
14. Review of the research status on the transmission and diffusion characteristics of indoor viral aerosol particles.
Huang Y; Wan J; Han S; Li Y
Environ Sci Pollut Res Int; 2024 Mar; 31(15):22308-22318. PubMed ID: 38430438
[TBL] [Abstract][Full Text] [Related]
15. Morphological variation and airflow dynamics in the human nose.
Churchill SE; Shackelford LL; Georgi JN; Black MT
Am J Hum Biol; 2004; 16(6):625-38. PubMed ID: 15495233
[TBL] [Abstract][Full Text] [Related]
16. How far droplets can move in indoor environments--revisiting the Wells evaporation-falling curve.
Xie X; Li Y; Chwang AT; Ho PL; Seto WH
Indoor Air; 2007 Jun; 17(3):211-25. PubMed ID: 17542834
[TBL] [Abstract][Full Text] [Related]
17. Multi-person movement-induced airflow and the effects on virus-laden expiratory droplet dispersion in indoor environments.
Wu J; Geng J; Fu M; Weng W
Indoor Air; 2022 Sep; 32(9):e13119. PubMed ID: 36168216
[TBL] [Abstract][Full Text] [Related]
18. Theoretical and numerical predictions of two-dimensional Aaberg slot exhaust hoods.
Wen X; Ingham DB
Ann Occup Hyg; 2000 Aug; 44(5):375-90. PubMed ID: 10930501
[TBL] [Abstract][Full Text] [Related]
19. Using large eddy simulation to study particle motions in a room.
Béghein C; Jiang Y; Chen QY
Indoor Air; 2005 Aug; 15(4):281-90. PubMed ID: 15982275
[TBL] [Abstract][Full Text] [Related]
20. Influence of room geometry and ventilation rate on airflow and aerosol dispersion: implications for worker protection.
Whicker JJ; Wasiolek PT; Tavani RA
Health Phys; 2002 Jan; 82(1):52-63. PubMed ID: 11768799
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]