These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 16872079)

  • 1. Measurement of head scatter factors of linear accelerators with columnar miniphantoms.
    Jursinic PA
    Med Phys; 2006 Jun; 33(6):1720-8. PubMed ID: 16872079
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of in-air output ratios using different miniphantom materials.
    Li J; Zhu TC
    Phys Med Biol; 2006 Aug; 51(15):3819-34. PubMed ID: 16861783
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurements of head-scatter factors with cylindrical build-up caps and columnar miniphantoms.
    Jursinic PA; Thomadsen BR
    Med Phys; 1999 Apr; 26(4):512-7. PubMed ID: 10227352
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurements of in-air output ratios for a linear accelerator with and without the flattening filter.
    Zhu XR; Kang Y; Gillin MT
    Med Phys; 2006 Oct; 33(10):3723-33. PubMed ID: 17089838
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monte Carlo simulation of the effect of miniphantom on in-air output ratio.
    Li J; Zhu TC
    Med Phys; 2010 Oct; 37(10):5228-37. PubMed ID: 21089756
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Lateral electron equilibrium and electron contamination in measurements of head-scatter factors using miniphantoms and brass caps.
    Li XA; Soubra M; Szanto J; Gerig LH
    Med Phys; 1995 Jul; 22(7):1167-70. PubMed ID: 7565391
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intercomparison of normalized head-scatter factor measurement techniques.
    Frye DM; Paliwal BR; Thomadsen BR; Jursinic P
    Med Phys; 1995 Feb; 22(2):249-53. PubMed ID: 7565357
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Study of head scatter factor in 4MV photon beam used in radiotherapy.
    Appasamy M; Xavier SV; Kuppusamy T; Velayudham R
    Technol Cancer Res Treat; 2013 Jun; 12(3):207-16. PubMed ID: 23369151
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of Material and Wall Thickness Buildup Caps on the Head Scatter Factor Measurements in Irregular Fields Shielded by Cerrobend.
    Jomehzadeh A; Shahbazi-Gahrouei D; Jahanbakhsh V
    J Med Signals Sens; 2017; 7(4):247-251. PubMed ID: 29204382
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Scatter factors for a 25-MV x-ray beam.
    Bjärngard BE
    Med Phys; 1993; 20(2 Pt 1):357-61. PubMed ID: 8497222
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dosimetry of 24-MV x rays from a linear accelerator.
    Krithivas G; Rao SN
    Med Phys; 1987; 14(2):274-81. PubMed ID: 3587155
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; the effects of buildup cap thickness and fabrication material.
    Jursinic PA; Yahnke CJ
    Med Phys; 2011 Oct; 38(10):5432-40. PubMed ID: 21992362
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Head scatter off-axis for megavoltage x rays.
    Zhu TC; Bjärngard BE
    Med Phys; 2003 Apr; 30(4):533-43. PubMed ID: 12722805
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of electron contamination on scatter correction factors for photon beam dosimetry.
    Venselaar J; Heukelom S; Jager N; Mijnheer B; van der Laarse R; van Gasteren H; van Kleffens H; Westermann C
    Med Phys; 1999 Oct; 26(10):2099-106. PubMed ID: 10535626
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measurements of electron beam peak scatter factors.
    Ding GX; Cygler JE
    Med Phys; 1998 Feb; 25(2):251-3. PubMed ID: 9507489
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator.
    Tyner E; McClean B; McCavana P; af Wetterstedt S
    Med Phys; 2009 Apr; 36(4):1318-29. PubMed ID: 19472639
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental determination of peripheral doses for different IMRT techniques delivered by a Siemens linear accelerator.
    Wiezorek T; Voigt A; Metzger N; Georg D; Schwedas M; Salz H; Wendt TG
    Strahlenther Onkol; 2008 Feb; 184(2):73-9. PubMed ID: 18259698
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of electron contamination of a 6 MV x-ray beam on near surface diode dosimetry.
    Edwards CR; Mountford PJ; Moloney AJ
    Phys Med Biol; 2006 Dec; 51(24):6471-82. PubMed ID: 17148830
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams.
    Hill R; Holloway L; Baldock C
    Phys Med Biol; 2005 Nov; 50(21):N331-44. PubMed ID: 16237233
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric evaluation of irradiation geometry and potential air gaps in an acrylic miniphantom used for external audit of absolute dose calibration for a hybrid 1.5 T MR-linac system.
    Tyagi N; Subashi E; Michael Lovelock D; Kry S; Alvarez PE; Hunt MA; Lim SB
    J Appl Clin Med Phys; 2022 Feb; 23(2):e13503. PubMed ID: 34914175
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.