129 related articles for article (PubMed ID: 16872079)
1. Measurement of head scatter factors of linear accelerators with columnar miniphantoms. Jursinic PA Med Phys; 2006 Jun; 33(6):1720-8. PubMed ID: 16872079 [TBL] [Abstract][Full Text] [Related]
2. Measurement of in-air output ratios using different miniphantom materials. Li J; Zhu TC Phys Med Biol; 2006 Aug; 51(15):3819-34. PubMed ID: 16861783 [TBL] [Abstract][Full Text] [Related]
3. Measurements of head-scatter factors with cylindrical build-up caps and columnar miniphantoms. Jursinic PA; Thomadsen BR Med Phys; 1999 Apr; 26(4):512-7. PubMed ID: 10227352 [TBL] [Abstract][Full Text] [Related]
4. Measurements of in-air output ratios for a linear accelerator with and without the flattening filter. Zhu XR; Kang Y; Gillin MT Med Phys; 2006 Oct; 33(10):3723-33. PubMed ID: 17089838 [TBL] [Abstract][Full Text] [Related]
5. Monte Carlo simulation of the effect of miniphantom on in-air output ratio. Li J; Zhu TC Med Phys; 2010 Oct; 37(10):5228-37. PubMed ID: 21089756 [TBL] [Abstract][Full Text] [Related]
6. Lateral electron equilibrium and electron contamination in measurements of head-scatter factors using miniphantoms and brass caps. Li XA; Soubra M; Szanto J; Gerig LH Med Phys; 1995 Jul; 22(7):1167-70. PubMed ID: 7565391 [TBL] [Abstract][Full Text] [Related]
7. Intercomparison of normalized head-scatter factor measurement techniques. Frye DM; Paliwal BR; Thomadsen BR; Jursinic P Med Phys; 1995 Feb; 22(2):249-53. PubMed ID: 7565357 [TBL] [Abstract][Full Text] [Related]
8. Study of head scatter factor in 4MV photon beam used in radiotherapy. Appasamy M; Xavier SV; Kuppusamy T; Velayudham R Technol Cancer Res Treat; 2013 Jun; 12(3):207-16. PubMed ID: 23369151 [TBL] [Abstract][Full Text] [Related]
9. Effect of Material and Wall Thickness Buildup Caps on the Head Scatter Factor Measurements in Irregular Fields Shielded by Cerrobend. Jomehzadeh A; Shahbazi-Gahrouei D; Jahanbakhsh V J Med Signals Sens; 2017; 7(4):247-251. PubMed ID: 29204382 [TBL] [Abstract][Full Text] [Related]
10. Scatter factors for a 25-MV x-ray beam. Bjärngard BE Med Phys; 1993; 20(2 Pt 1):357-61. PubMed ID: 8497222 [TBL] [Abstract][Full Text] [Related]
11. Dosimetry of 24-MV x rays from a linear accelerator. Krithivas G; Rao SN Med Phys; 1987; 14(2):274-81. PubMed ID: 3587155 [TBL] [Abstract][Full Text] [Related]
12. In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; the effects of buildup cap thickness and fabrication material. Jursinic PA; Yahnke CJ Med Phys; 2011 Oct; 38(10):5432-40. PubMed ID: 21992362 [TBL] [Abstract][Full Text] [Related]
13. Head scatter off-axis for megavoltage x rays. Zhu TC; Bjärngard BE Med Phys; 2003 Apr; 30(4):533-43. PubMed ID: 12722805 [TBL] [Abstract][Full Text] [Related]
14. Effect of electron contamination on scatter correction factors for photon beam dosimetry. Venselaar J; Heukelom S; Jager N; Mijnheer B; van der Laarse R; van Gasteren H; van Kleffens H; Westermann C Med Phys; 1999 Oct; 26(10):2099-106. PubMed ID: 10535626 [TBL] [Abstract][Full Text] [Related]
15. Measurements of electron beam peak scatter factors. Ding GX; Cygler JE Med Phys; 1998 Feb; 25(2):251-3. PubMed ID: 9507489 [TBL] [Abstract][Full Text] [Related]
16. Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator. Tyner E; McClean B; McCavana P; af Wetterstedt S Med Phys; 2009 Apr; 36(4):1318-29. PubMed ID: 19472639 [TBL] [Abstract][Full Text] [Related]
17. Experimental determination of peripheral doses for different IMRT techniques delivered by a Siemens linear accelerator. Wiezorek T; Voigt A; Metzger N; Georg D; Schwedas M; Salz H; Wendt TG Strahlenther Onkol; 2008 Feb; 184(2):73-9. PubMed ID: 18259698 [TBL] [Abstract][Full Text] [Related]
18. Effect of electron contamination of a 6 MV x-ray beam on near surface diode dosimetry. Edwards CR; Mountford PJ; Moloney AJ Phys Med Biol; 2006 Dec; 51(24):6471-82. PubMed ID: 17148830 [TBL] [Abstract][Full Text] [Related]
19. A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams. Hill R; Holloway L; Baldock C Phys Med Biol; 2005 Nov; 50(21):N331-44. PubMed ID: 16237233 [TBL] [Abstract][Full Text] [Related]
20. Dosimetric evaluation of irradiation geometry and potential air gaps in an acrylic miniphantom used for external audit of absolute dose calibration for a hybrid 1.5 T MR-linac system. Tyagi N; Subashi E; Michael Lovelock D; Kry S; Alvarez PE; Hunt MA; Lim SB J Appl Clin Med Phys; 2022 Feb; 23(2):e13503. PubMed ID: 34914175 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]