These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 16872085)

  • 1. An MLC-based linac QA procedure for the characterization of radiation isocenter and room lasers' position.
    Rosca F; Lorenz F; Hacker FL; Chin LM; Ramakrishna N; Zygmanski P
    Med Phys; 2006 Jun; 33(6):1780-7. PubMed ID: 16872085
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technical note: Comprehensive evaluations of gantry and couch rotation isocentricities for implementing proton stereotactic radiosurgery.
    Shen J; Robertson DG; Bues M; Shipulin K; Liu W; Stoker J; Ashman JB; Lara P; Keole SR; Wong W; Vora SA
    Med Phys; 2023 Jun; 50(6):3359-3367. PubMed ID: 36959772
    [TBL] [Abstract][Full Text] [Related]  

  • 3. SU-E-T-88: Evaluating Gantry Sag on Linear Accelerators and Introducing an MLC-Based Compensation Strategy.
    Du W; Gao S; Wang X; Kudchadker R
    Med Phys; 2012 Jun; 39(6Part11):3722-3723. PubMed ID: 28517157
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery.
    Rowshanfarzad P; Sabet M; O'Connor DJ; Greer PB
    Med Phys; 2011 Jul; 38(7):3963-70. PubMed ID: 21858993
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterization of mechanical and radiation isocenter on an MR-guided radiotherapy (MRgRT) Linac.
    Bassiri N; Bayouth JE; Mittauer KE
    J Appl Clin Med Phys; 2023 Nov; 24(11):e14111. PubMed ID: 37535938
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantifying the gantry sag on linear accelerators and introducing an MLC-based compensation strategy.
    Du W; Gao S; Wang X; Kudchadker RJ
    Med Phys; 2012 Apr; 39(4):2156-62. PubMed ID: 22482636
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous Optimization of Radiation-Imaging Coincidence for a Multi-Energy Linac.
    Knill C; Sandhu R; Halford R; Snyder M; Lack D
    J Med Phys; 2021; 46(2):105-110. PubMed ID: 34566290
    [TBL] [Abstract][Full Text] [Related]  

  • 8. SU-E-J-49: Reliability Study of ExacTrac- System Image Isocenter Using an On-Demand QA Procedure.
    Wang X; Zhao Z; Du W; Li X; Yang J
    Med Phys; 2012 Jun; 39(6Part6):3663. PubMed ID: 28517561
    [TBL] [Abstract][Full Text] [Related]  

  • 9. SU-E-T-133: Isocenter Measurements with the Winston-Lutz Test: Impact on Treatment Planning.
    Templeton A; Chu J; Turian J
    Med Phys; 2012 Jun; 39(6Part11):3733-3734. PubMed ID: 28517166
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A novel method to determine linac mechanical isocenter position and size and examples of specific QA applications.
    Chojnowski JM; Sykes JR; Thwaites DI
    J Appl Clin Med Phys; 2021 Jul; 22(7):44-55. PubMed ID: 34056850
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The impact of isocentric shifts on delivery accuracy during the irradiation of small cerebral targets-Quantification and possible corrections.
    Wack LJ; Exner F; Wegener S; Sauer OA
    J Appl Clin Med Phys; 2020 May; 21(5):56-64. PubMed ID: 32196950
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of the RUBY modular QA phantom for planar and non-coplanar VMAT and stereotactic radiations.
    Poppinga D; Kretschmer J; Brodbek L; Meyners J; Poppe B; Looe HK
    J Appl Clin Med Phys; 2020 Oct; 21(10):69-79. PubMed ID: 32797670
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automating linear accelerator quality assurance.
    Eckhause T; Al-Hallaq H; Ritter T; DeMarco J; Farrey K; Pawlicki T; Kim GY; Popple R; Sharma V; Perez M; Park S; Booth JT; Thorwarth R; Moran JM
    Med Phys; 2015 Oct; 42(10):6074-83. PubMed ID: 26429282
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gantry and isocenter displacements of a linear accelerator caused by an add-on micromultileaf collimator.
    Riis HL; Zimmermann SJ; Hjelm-Hansen M
    Med Phys; 2013 Mar; 40(3):031707. PubMed ID: 23464302
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new irradiation unit constructed of self-moving gantry-CT and linac.
    Kuriyama K; Onishi H; Sano N; Komiyama T; Aikawa Y; Tateda Y; Araki T; Uematsu M
    Int J Radiat Oncol Biol Phys; 2003 Feb; 55(2):428-35. PubMed ID: 12527056
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A measurement technique to determine the calibration accuracy of an electromagnetic tracking system to radiation isocenter.
    Litzenberg DW; Gallagher I; Masi KJ; Lee C; Prisciandaro JI; Hamstra DA; Ritter T; Lam KL
    Med Phys; 2013 Aug; 40(8):081711. PubMed ID: 23927308
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An EPID-based method to determine mechanical deformations in a linear accelerator.
    Gourdeau D; Gingras L; Beaulieu F; Leclerc G; Archambault L
    Med Phys; 2018 Nov; 45(11):5054-5065. PubMed ID: 30242848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests.
    Du W; Johnson JL; Jiang W; Kudchadker RJ
    J Appl Clin Med Phys; 2016 Jan; 17(1):167-178. PubMed ID: 26894350
    [TBL] [Abstract][Full Text] [Related]  

  • 19. SU-E-T-420: Development of a Comprehensive Linac-Based Quality Assurance Procedure for Retrofitted Micro-MLC SRS System.
    Hancock G; Pearson D
    Med Phys; 2012 Jun; 39(6Part16):3801. PubMed ID: 28517201
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measuring the wobble of radiation field centers during gantry rotation and collimator movement on a linear accelerator.
    Du W; Gao S
    Med Phys; 2011 Aug; 38(8):4575-8. PubMed ID: 21928629
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.