BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 16872425)

  • 1. Optimized HREM imaging of objects supported by amorphous substrates using spherical aberration adjustment.
    Allsop NA; Dobson PJ; Hutchison JL
    J Microsc; 2006 Jul; 223(Pt 1):1-8. PubMed ID: 16872425
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The tuning of a Zernike phase plate with defocus and variable spherical aberration and its use in HRTEM imaging.
    Lentzen M
    Ultramicroscopy; 2004 Jun; 99(4):211-20. PubMed ID: 15149715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Direct imaging of local atomic ordering in a Pd-Ni-P bulk metallic glass using Cs-corrected transmission electron microscopy.
    Hirata A; Hirotsu Y; Nieh TG; Ohkubo T; Tanaka N
    Ultramicroscopy; 2007; 107(2-3):116-23. PubMed ID: 16872747
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Contrast transfer and resolution limits for sub-angstrom high-resolution transmission electron microscopy.
    Lentzen M
    Microsc Microanal; 2008 Feb; 14(1):16-26. PubMed ID: 18096097
    [TBL] [Abstract][Full Text] [Related]  

  • 5. On the importance of fifth-order spherical aberration for a fully corrected electron microscope.
    Chang LY; Kirkland AI; Titchmarsh JM
    Ultramicroscopy; 2006 Mar; 106(4-5):301-6. PubMed ID: 16309838
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Three-dimensional imaging in double aberration-corrected scanning confocal electron microscopy, part I: elastic scattering.
    Cosgriff EC; D'Alfonso AJ; Allen LJ; Findlay SD; Kirkland AI; Nellist PD
    Ultramicroscopy; 2008 Nov; 108(12):1558-66. PubMed ID: 18639381
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Physical limits on atomic resolution.
    Van Dyck D; Van Aert S; den Dekker AJ
    Microsc Microanal; 2004 Feb; 10(1):153-7. PubMed ID: 15306080
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Progress in aberration-corrected high-resolution transmission electron microscopy using hardware aberration correction.
    Lentzen M
    Microsc Microanal; 2006 Jun; 12(3):191-205. PubMed ID: 17481356
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimizing phase contrast in transmission electron microscopy with an electrostatic (Boersch) phase plate.
    Majorovits E; Barton B; Schultheiss K; Pérez-Willard F; Gerthsen D; Schröder RR
    Ultramicroscopy; 2007; 107(2-3):213-26. PubMed ID: 16949755
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Structural imaging of beta-Si3N4 by spherical aberration-corrected high-resolution transmission electron microscopy.
    Zhang Z; Kaiser U
    Ultramicroscopy; 2009 Aug; 109(9):1114-20. PubMed ID: 19493621
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Linear versus non-linear structural information limit in high-resolution transmission electron microscopy.
    Van Aert S; Chen JH; Van Dyck D
    Ultramicroscopy; 2010 Oct; 110(11):1404-10. PubMed ID: 20655146
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Atomic imaging in aberration-corrected high-resolution transmission electron microscopy.
    Chen JH; Zandbergen HW; Dyck DV
    Ultramicroscopy; 2004 Jan; 98(2-4):81-97. PubMed ID: 15046789
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-resolution transmission electron microscopy using negative spherical aberration.
    Jia CL; Lentzen M; Urban K
    Microsc Microanal; 2004 Apr; 10(2):174-84. PubMed ID: 15306044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effective object planes for aberration-corrected transmission electron microscopy.
    Yu R; Lentzen M; Zhu J
    Ultramicroscopy; 2012 Jan; 112(1):15-21. PubMed ID: 22081044
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of a physical phase plate on contrast transfer in an aberration-corrected transmission electron microscope.
    Gamm B; Schultheiss K; Gerthsen D; Schröder RR
    Ultramicroscopy; 2008 Aug; 108(9):878-84. PubMed ID: 18456408
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Imaging of radiation-sensitive samples in transmission electron microscopes equipped with Zernike phase plates.
    Malac M; Beleggia M; Egerton R; Zhu Y
    Ultramicroscopy; 2008 Jan; 108(2):126-40. PubMed ID: 17509765
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Atomic structure of Beta-tantalum nanocrystallites.
    Tillmann K; Thust A; Gerber A; Weides MP; Urban K
    Microsc Microanal; 2005 Dec; 11(6):534-44. PubMed ID: 17481332
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Contrast Transfer Function approach for image calculations in standard and aberration-corrected LEEM and PEEM.
    Schramm SM; Pang AB; Altman MS; Tromp RM
    Ultramicroscopy; 2012 Apr; 115():88-108. PubMed ID: 22209472
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A simple method for minimizing non-linear image contrast in spherical aberration-corrected HRTEM.
    Yamasaki J; Kawai T; Tanaka N
    J Electron Microsc (Tokyo); 2005 Jun; 54(3):209-14. PubMed ID: 16123057
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of amorphous layers on ADF-STEM imaging.
    Mkhoyan KA; Maccagnano-Zacher SE; Kirkland EJ; Silcox J
    Ultramicroscopy; 2008 Jul; 108(8):791-803. PubMed ID: 18374489
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.