These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 16872434)

  • 1. Preparation of TEM samples of metal-oxide interface by the focused ion beam technique.
    Abolhassani S; Gasser P
    J Microsc; 2006 Jul; 223(Pt 1):73-82. PubMed ID: 16872434
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technique for preparation and characterization in cross-section of oral titanium implant surfaces using focused ion beam and transmission electron microscopy.
    Jarmar T; Palmquist A; Brånemark R; Hermansson L; Engqvist H; Thomsen P
    J Biomed Mater Res A; 2008 Dec; 87(4):1003-9. PubMed ID: 18257067
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Site-specific specimen preparation by focused ion beam milling for transmission electron microscopy of metal matrix composites.
    Gasser P; Klotz UE; Khalid FA; Beffort O
    Microsc Microanal; 2004 Apr; 10(2):311-6. PubMed ID: 15306057
    [TBL] [Abstract][Full Text] [Related]  

  • 4. TEM foil preparation of sub-micrometre sized individual grains by focused ion beam technique.
    Holzapfel C; Soldera F; Vollmer C; Hoppe P; Mücklich F
    J Microsc; 2009 Jul; 235(1):59-66. PubMed ID: 19566627
    [TBL] [Abstract][Full Text] [Related]  

  • 5. TEM sample preparation by FIB for carbon nanotube interconnects.
    Ke X; Bals S; Romo Negreira A; Hantschel T; Bender H; Van Tendeloo G
    Ultramicroscopy; 2009 Oct; 109(11):1353-9. PubMed ID: 19665846
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A novel tool for high-resolution transmission electron microscopy of intact interfaces between bone and metallic implants.
    Engqvist H; Botton GA; Couillard M; Mohammadi S; Malmström J; Emanuelsson L; Hermansson L; Phaneuf MW; Thomsen P
    J Biomed Mater Res A; 2006 Jul; 78(1):20-4. PubMed ID: 16596587
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combining Ar ion milling with FIB lift-out techniques to prepare high quality site-specific TEM samples.
    Huang Z
    J Microsc; 2004 Sep; 215(Pt 3):219-23. PubMed ID: 15312185
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transmission Electron Microscope Specimen Preparation of Metal Matrix Composites Using the Focused Ion Beam Miller.
    Cairney JM; Smith RD; Munroe PR
    Microsc Microanal; 2000 Sep; 6(5):452-462. PubMed ID: 11003680
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preparation of cross-sectional TEM samples for low-angle ion milling.
    McCaffrey JP; Barna A
    Microsc Res Tech; 1997 Mar; 36(5):362-7. PubMed ID: 9140935
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cross-sectional Specimen Preparation and Observation of a Plasma Sprayed Coating Using a Focused Ion Beam/Transmission Electron Microscopy System.
    Yaguchi T; Kamino T; Sasaki M; Barbezat G; Urao R
    Microsc Microanal; 2000 May; 6(3):218-223. PubMed ID: 10790490
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Two-dimensional and 3-dimensional analysis of bone/dental implant interfaces with the use of focused ion beam and electron microscopy.
    Giannuzzi LA; Phifer D; Giannuzzi NJ; Capuano MJ
    J Oral Maxillofac Surg; 2007 Apr; 65(4):737-47. PubMed ID: 17368372
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Focused ion beam sectioning and lift-out method for copper and resist vias in organic low-k dielectrics.
    Crawford EJ; Gignac L; Barth K; Petrus J; Levine E
    Microsc Microanal; 2002 Dec; 8(6):502-8. PubMed ID: 12533211
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultrastructural characterization of tooth-biomaterial interfaces prepared with broad and focused ion beams.
    Coutinho E; Jarmar T; Svahn F; Neves AA; Verlinden B; Van Meerbeek B; Engqvist H
    Dent Mater; 2009 Nov; 25(11):1325-37. PubMed ID: 19596422
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cross-sectional sample preparation by focused ion beam: a review of ion-sample interaction.
    Ishitani T; Yaguchi T
    Microsc Res Tech; 1996 Nov; 35(4):320-33. PubMed ID: 8987026
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Novel method for the plan-view TEM preparation of thin samples on brittle substrates by mechanical and ion beam thinning.
    Sáfrán G; Grenet T
    Microsc Res Tech; 2002 Feb; 56(4):308-14. PubMed ID: 11877808
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preparation for TEM of layered samples with fragile microstructure and weak layer interface.
    Westman AK; Wei LY; Barre F
    Microsc Res Tech; 1999 May; 45(3):198-202. PubMed ID: 10344771
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The focused ion beam fold-out: sample preparation method for transmission electron microscopy.
    Floresca HC; Jeon J; Wang JG; Kim MJ
    Microsc Microanal; 2009 Dec; 15(6):558-63. PubMed ID: 19804654
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An in situ heating TEM analysis method for an interface reaction.
    Tanigaki T; Ito K; Nagakubo Y; Asakawa T; Kanemura T
    J Electron Microsc (Tokyo); 2009 Oct; 58(5):281-7. PubMed ID: 19376815
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transmission electron microscopy of fluorapatite-gelatine composite particles prepared using focused ion beam milling.
    Volkert CA; Busch S; Heiland B; Dehm G
    J Microsc; 2004 Jun; 214(Pt 3):208-12. PubMed ID: 15157188
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transmission electron microscopy and atom probe specimen preparation from mechanically alloyed powder using the focused ion-beam lift-out technique.
    Choi PP; Kwon YS; Kim JS; Al-Kassab T
    J Electron Microsc (Tokyo); 2007 Apr; 56(2):43-9. PubMed ID: 17928320
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.