117 related articles for article (PubMed ID: 16873784)
1. A critical appraisal of the continuous glucose-error grid analysis.
Wentholt IM; Hoekstra JB; Devries JH
Diabetes Care; 2006 Aug; 29(8):1805-11. PubMed ID: 16873784
[TBL] [Abstract][Full Text] [Related]
2. Assessment of blood glucose predictors: the prediction-error grid analysis.
Sivananthan S; Naumova V; Man CD; Facchinetti A; Renard E; Cobelli C; Pereverzyev SV
Diabetes Technol Ther; 2011 Aug; 13(8):787-96. PubMed ID: 21612393
[TBL] [Abstract][Full Text] [Related]
3. Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data.
Kovatchev BP; Gonder-Frederick LA; Cox DJ; Clarke WL
Diabetes Care; 2004 Aug; 27(8):1922-8. PubMed ID: 15277418
[TBL] [Abstract][Full Text] [Related]
4. Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: comparison with frequent laboratory reference measurements.
Weinstein RL; Schwartz SL; Brazg RL; Bugler JR; Peyser TA; McGarraugh GV
Diabetes Care; 2007 May; 30(5):1125-30. PubMed ID: 17337488
[TBL] [Abstract][Full Text] [Related]
5. Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis.
Clarke WL; Anderson S; Farhy L; Breton M; Gonder-Frederick L; Cox D; Kovatchev B
Diabetes Care; 2005 Oct; 28(10):2412-7. PubMed ID: 16186272
[TBL] [Abstract][Full Text] [Related]
6. Evaluating clinical accuracy of continuous glucose monitoring systems: Continuous Glucose-Error Grid Analysis (CG-EGA).
Clarke WL; Anderson S; Kovatchev B
Curr Diabetes Rev; 2008 Aug; 4(3):193-9. PubMed ID: 18690900
[TBL] [Abstract][Full Text] [Related]
7. Efficacy of continuous glucose monitoring system (CGMS) to detect postprandial hyperglycemia and unrecognized hypoglycemia in type 1 diabetic patients.
Maia FF; Araújo LR
Diabetes Res Clin Pract; 2007 Jan; 75(1):30-4. PubMed ID: 16806560
[TBL] [Abstract][Full Text] [Related]
8. No apparent local effect of insulin on microdialysis continuous glucose- monitoring measurements.
Hermanides J; Wentholt IM; Hart AA; Hoekstra JB; DeVries JH
Diabetes Care; 2008 Jun; 31(6):1120-2. PubMed ID: 18332157
[TBL] [Abstract][Full Text] [Related]
9. Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care.
Chase JG; Hann CE; Jackson M; Lin J; Lotz T; Wong XW; Shaw GM
Comput Methods Programs Biomed; 2006 Jun; 82(3):238-47. PubMed ID: 16647157
[TBL] [Abstract][Full Text] [Related]
10. Glucose Prediction Algorithms from Continuous Monitoring Data: Assessment of Accuracy via Continuous Glucose Error-Grid Analysis.
Zanderigo F; Sparacino G; Kovatchev B; Cobelli C
J Diabetes Sci Technol; 2007 Sep; 1(5):645-51. PubMed ID: 19718282
[TBL] [Abstract][Full Text] [Related]
11. Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats.
Woderer S; Henninger N; Garthe CD; Kloetzer HM; Hajnsek M; Kamecke U; Gretz N; Kraenzlin B; Pill J
Anal Chim Acta; 2007 Jan; 581(1):7-12. PubMed ID: 17386418
[TBL] [Abstract][Full Text] [Related]
12. Performance of a new real-time continuous glucose monitoring system: A multicenter pilot study.
Zhou J; Zhang S; Li L; Wang Y; Lu W; Sheng C; Li Y; Bao Y; Jia W
J Diabetes Investig; 2018 Mar; 9(2):286-293. PubMed ID: 28563974
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of subcutaneously-implanted glucose sensors for continuous glucose measurements in hyperglycemic pigs.
Kvist PH; Bielecki M; Gerstenberg M; Rossmeisl C; Jensen HE; Rolin B; Hasselager E
In Vivo; 2006; 20(2):195-203. PubMed ID: 16634519
[TBL] [Abstract][Full Text] [Related]
14. Real-time glucose sensors in children and adolescents with type-1 diabetes.
Danne T; Lange K; Kordonouri O
Horm Res; 2008; 70(4):193-202. PubMed ID: 18772591
[TBL] [Abstract][Full Text] [Related]
15. Accuracy of the EasyTouch blood glucose self-monitoring system: a study of 516 cases.
Dai KS; Tai DY; Ho P; Chen CC; Peng WC; Chen ST; Hsu CC; Liu YP; Hsieh HC; Yang CC; Tsai MC; Mao SJ
Clin Chim Acta; 2004 Nov; 349(1-2):135-41. PubMed ID: 15469866
[TBL] [Abstract][Full Text] [Related]
16. Assessment of different techniques for subcutaneous glucose monitoring in Type 1 diabetic patients during 'real-life' glucose excursions.
Mader JK; Weinhandl H; Köhler G; Plank J; Bock G; Korsatko S; Ratzer M; Ikeoka D; Köhler H; Pieber TR; Ellmerer M
Diabet Med; 2010 Mar; 27(3):332-8. PubMed ID: 20536497
[TBL] [Abstract][Full Text] [Related]
17. Sensor-augmented pump therapy in type 1 diabetes.
Weinzimer SA; Tamborlane WV
Curr Opin Endocrinol Diabetes Obes; 2008 Apr; 15(2):118-22. PubMed ID: 18316945
[TBL] [Abstract][Full Text] [Related]
18. A comparison of blood glucose meters in Australia.
Cohen M; Boyle E; Delaney C; Shaw J
Diabetes Res Clin Pract; 2006 Feb; 71(2):113-8. PubMed ID: 16011856
[TBL] [Abstract][Full Text] [Related]
19. Real-time continuous glucose monitoring using GuardianRT: from research to clinical practice.
Tubiana-Rufi N; Riveline JP; Dardari D
Diabetes Metab; 2007 Dec; 33(6):415-20. PubMed ID: 17988918
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of a continuous glucose monitoring system for home-use conditions.
Bode B; Silver M; Weiss R; Martin K
Manag Care; 2008 Aug; 17(8):40-5. PubMed ID: 18777789
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]